- DS201 M B20 G30
ABB DS201 M B20 G30 is a DIN-rail leakage protection circuit breaker with a B tripping characteristic, Type A/G residual current, 20 A rated current, and 30 mA rated residual current. It is a two-pole device with one protected pole and occupies two modular spacings. Rated operational voltage is 240 V AC according to IEC 60898-1; rated insulation voltage is 500 V according to IEC/EN 60664-1, rated impulse withstand voltage is 4 kV, and rated frequency is 50 to 60 Hz. Rated short-circuit capacity is 10 kA, rated ultimate short-circuit breaking capacity is 15 kA, and rated service short-circuit breaking capacity is 11.2 kA. Standards: IEC/EN 61009-1, IEC/EN 61009-2-1, OVE E 8601. Electrical endurance is 10000 cycles; mechanical endurance is 20000 cycles. Operating ambient air temperature is -25 to 55 degrees C. Dimensions are 35 mm width, 85 mm height, 69 mm depth; net weight 200 g.
- DS201 M B25 A100
ABB DS201 M B25 A100 is a 1P+N residual current breaker (RCBO) for single-phase circuits. It has a rated current of 25 A, rated residual current of 100 mA, Type A residual current, and B tripping characteristic. Rated operational voltage is 240 V AC according to IEC 60898-1; rated impulse withstand voltage is 4 kV. Rated short-circuit capacity is 10 kA, rated ultimate short-circuit breaking capacity (Icu) is 15 kA, and rated service short-circuit breaking capacity (Ics) is 11.2 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. DIN-rail mounting, two modular spacings, 35 mm wide, 85 mm high, 69 mm deep, 200 g. Operating ambient air temperature is -25 to 55 °C. Screw terminals accept 0.75 to 25 mm² conductors; tightening torque is 2.8 N·m.
- DS201 M B25 A30
The ABB DS201 M B25 A30 is a 1P+N leakage protection circuit breaker with B tripping characteristic and Type A residual current detection. It is rated 25 A with 30 mA rated residual current, 240 V AC rated operational voltage per IEC 60898-1, and 50 to 60 Hz rated frequency. Rated short-circuit capacity is 10 kA, rated ultimate short-circuit breaking capacity (Icu) is 15 kA, and rated service short-circuit breaking capacity (Ics) is 11.2 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. Two poles, one protected, two modular spacings, DIN-rail mounting, screw terminals with 2.8 N·m tightening torque, IP20/IP40, and an operating ambient air temperature range of -25 to 55 °C.
- DS201 M B25 A30 110V
ABB DS201 M B25 A30 110V leakage protection circuit breaker, 1P+N, with 25 A rated current and 30 mA Type A residual current. Tripping characteristic B. Rated operational voltage 240 V AC per IEC 60898-1; rated insulation voltage 500 V per IEC/EN 60664-1; rated impulse withstand voltage 4 kV; test voltage 110 V. Rated short-circuit capacity 10 kA, rated ultimate short-circuit breaking capacity 15 kA, rated service short-circuit breaking capacity 11.2 kA. Rated frequency 50 to 60 Hz. Two poles, one protected, two modular spacings, DIN-rail mounting. Screw terminals, tightening torque 2.8 N·m, wire stripping length 12 mm. Dimensions 35 mm x 85 mm x 69 mm, 200 g. Standards: IEC 61009-1, IEC 61009-2-1.
- DS201 M B25 A300
ABB DS201 M B25 A300 is a 1P+N residual current circuit breaker (RCBO) with two poles and one protected pole, rated 25 A and 300 mA residual current, type A. Tripping characteristic B, instantaneous operating characteristic. Rated operational voltage 240 V AC per IEC 60898-1; rated insulation voltage 500 V per IEC/EN 60664-1; rated impulse withstand voltage 4 kV; dielectric test voltage 2 kV. Rated short-circuit capacity 10 kA; rated ultimate short-circuit breaking capacity 15 kA; rated service short-circuit breaking capacity 11.2 kA. Rated frequency 50 to 60 Hz. Standards: IEC/EN 61009-1, IEC/EN 61009-2-1. Two-module DIN-rail mounting, 35 mm wide, 85 mm high, 69 mm deep, 200 g. Screw terminals, tightening torque 2.8 N·m. Ambient air temperature -25 to 55 °C. Degree of protection IP20, IP40.
- DS201 M B25 AC100
The ABB DS201 M B25 AC100 is a 1P+N leakage protection circuit breaker with a rated current of 25 A and rated residual current of 100 mA, Type AC. Tripping characteristic is B. It is rated 240 V AC according to IEC 60898-1 and operates at 50 to 60 Hz. Rated ultimate short-circuit breaking capacity (Icu) is 15 kA; rated service short-circuit breaking capacity (Ics) is 11.2 kA; rated conditional short-circuit current (Inc) is 15 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. Electrical endurance is 10000 cycles and mechanical endurance is 20000 cycles. It mounts on DIN rail, has screw terminals with 2.8 N·m tightening torque, and operates from -25 to 55 °C. Dimensions are 35 mm width, 85 mm height, 69 mm depth, 200 g weight.
- DS201 M B25 AC30
The ABB DS201 M B25 AC30 is a 1P+N leakage protection circuit breaker with a B tripping characteristic and Type AC residual current detection. Rated current is 25 A with a rated residual current of 30 mA. Rated short-circuit capacity is 10 kA, rated ultimate short-circuit breaking capacity is 15 kA, and rated service short-circuit breaking capacity is 11.2 kA. It is rated 240 V AC according to IEC 60898-1 and operates at 50 to 60 Hz. The device conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. It mounts on DIN rail, occupies two modular spacings, and measures 35 mm wide, 85 mm high, and 69 mm deep. Screw terminals accept conductors from 0.75 to 25 mm². Operating ambient temperature is -25 to 55 °C.
- DS201 M B25 AC300
The ABB DS201 M B25 AC300 is a 1P+N leakage protection circuit breaker with a rated current of 25 A and a rated residual current of 300 mA. It has a Type AC residual current, B tripping characteristic, and a rated short-circuit capacity of 10 kA. Rated operational voltage is 240 V AC according to IEC 60898-1, with a rated insulation voltage of 500 V per IEC/EN 60664-1 and a rated impulse withstand voltage of 4 kV. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. It mounts on DIN rail, occupies two modular spacings, and measures 35 mm wide, 85 mm high, and 69 mm deep, weighing 200 g.