- DS201 M C10 AC30
ABB DS201 M C10 AC30 is a two-pole leakage protection circuit breaker with one protected pole, rated 10 A and 30 mA residual current, Type AC. Tripping characteristic C. Rated operational voltage 240 V AC per IEC 60898-1; rated insulation voltage 500 V per IEC/EN 60664-1; rated impulse withstand voltage 4 kV. Rated short-circuit capacity 10 kA, rated ultimate short-circuit breaking capacity 15 kA, rated service short-circuit breaking capacity 11.2 kA. Rated frequency 50 to 60 Hz. Standards: IEC/EN 61009-1 and IEC/EN 61009-2-1. DIN-rail mounting, two modular spacings, 35 mm wide, 85 mm high, 69 mm deep, 200 g. Screw terminals, tightening torque 2.8 N·m. Operating ambient air temperature -25 to 55 °C. Degree of protection IP20, IP40.
- DS201 M C10 AC300
ABB DS201 M C10 AC300 is a 1P+N leakage protection circuit breaker with overcurrent protection. It has a rated current of 10 A, C tripping characteristic, Type AC residual current, and rated residual current of 300 mA. Rated operational voltage is 240 V AC according to IEC 60898-1; rated insulation voltage is 500 V according to IEC/EN 60664-1. Rated short-circuit capacity is 10 kA, rated ultimate short-circuit breaking capacity is 15 kA, and rated service short-circuit breaking capacity is 11.2 kA. It is rated 50 to 60 Hz, with total power loss of 2.3 W. It mounts on DIN rail with 2 modular spacings, 35 mm wide, 85 mm high, and 69 mm deep. Standards: IEC/EN 61009-1 and IEC/EN 61009-2-1.
- DS201 M C10 APR100
The ABB DS201 M C10 APR100 is a 1P+N residual current operated circuit breaker with integral overcurrent protection, rated 10 A with C tripping characteristic and 100 mA Type A residual current sensitivity. It is rated 240 V AC according to IEC 60898-1, with rated insulation voltage 500 V per IEC/EN 60664-1 and rated impulse withstand voltage 4 kV. Short-circuit ratings include 10 kA rated short-circuit capacity, 15 kA Icu, 11.2 kA Ics, and 15 kA Inc. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. The device occupies two DIN-rail modules, measures 35 mm wide by 85 mm high by 69 mm deep, weighs 200 g, and operates from -25 to 55 degrees C. Terminals accept conductors from 0.75 to 25 square millimeters.
- DS201 M C10 APR30
The ABB DS201 M C10 APR30 is a 1P+N leakage protection circuit breaker with a C tripping characteristic and Type A residual current detection. It has a rated current of 10 A, rated residual current of 30 mA, and rated operational voltage of 240 V AC according to IEC 60898-1. Rated short-circuit capacity is 10 kA, rated ultimate short-circuit breaking capacity is 15 kA, and rated service short-circuit breaking capacity is 11.2 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. The device mounts on DIN rail, occupies two modular spacings, and measures 35 mm wide, 85 mm high, and 69 mm deep. Screw terminals accept conductors from 0.75 to 25 mm². Operating ambient air temperature is -25 to 55 °C.
- DS201 M C10 APR300
ABB DS201 M C10 APR300 is a 1P+N leakage protection circuit breaker with a rated current of 10 A and rated residual current of 300 mA, Type A. It has a C tripping characteristic and an instantaneous APR high-immunity operating characteristic. Rated operational voltage is 240 V AC according to IEC 60898-1; rated insulation voltage is 500 V according to IEC/EN 60664-1. Rated short-circuit capacity is 10 kA, rated ultimate short-circuit breaking capacity is 15 kA, and rated service short-circuit breaking capacity is 11.2 kA. It is a two-pole device with one protected pole, two modular spacings, DIN-rail mounting, screw terminals, 35 mm net width, 85 mm net height, 69 mm net depth, and 200 g net weight. Standards: IEC/EN 61009-1 and IEC/EN 61009-2-1.
- DS201 M C10 F10
ABB DS201 M C10 F10 leakage protection circuit breaker, 2CSR275580R0104. Rated current 10 A, rated residual current 10 mA, Type F residual current, C tripping characteristic. Rated short-circuit capacity 10 kA; rated ultimate short-circuit breaking capacity (Icu) 15 kA; rated service short-circuit breaking capacity (Ics) 11.2 kA. Rated operational voltage according to IEC 60898-1 240 V AC, 50 to 60 Hz. Rated impulse withstand voltage (Uimp) 4 kV. Two poles, one protected pole, two modular spacings, DIN-rail mounting, screw terminals, tightening torque 2.8 N·m. Standards: IEC/EN 61009-1, IEC/EN 61009-2-1. Dimensions 35 mm width, 85 mm height, 69 mm depth; net weight 200 g. Operating ambient air temperature -25 to 55 °C.
- DS201 M C10 F30
ABB DS201 M C10 F30 is a 1P+N leakage protection circuit breaker with a C tripping characteristic and Type F residual current. It has a rated current of 10 A and a rated residual current of 30 mA. Rated operational voltage is 240 V AC according to IEC 60898-1, rated insulation voltage is 500 V according to IEC/EN 60664-1, and rated impulse withstand voltage is 4 kV. Rated short-circuit capacity is 10 kA, rated ultimate short-circuit breaking capacity is 15 kA, and rated service short-circuit breaking capacity is 11.2 kA. It is a two-module DIN-rail device, 35 mm wide, 85 mm high, and 69 mm deep, with screw terminals and 2.8 N·m tightening torque. Standards: IEC/EN 61009-1 and IEC/EN 61009-2-1.
- DS201 M C10 G30
ABB DS201 M C10 G30 leakage protection circuit breaker, 1P+N, DIN-rail mounting. Rated current 10 A with C tripping characteristic; rated residual current 30 mA, Type A/G. Rated operational voltage 230 V AC per IEC 60898-1; rated insulation voltage 500 V per IEC/EN 60664-1; rated impulse withstand voltage 4 kV; dielectric test voltage 2 kV. Rated short-circuit capacity 10 kA, rated ultimate short-circuit breaking capacity (Icu) 15 kA, rated service short-circuit breaking capacity (Ics) 11.2 kA. Rated frequency 50 to 60 Hz. Screw terminals accept rigid 0.75 to 25 mm² and flexible 0.75 to 16 mm² conductors; tightening torque 1.2 N·m. Toggle actuator with red ON / green OFF contact position indication and blue fault flag. Two modular spacings, 35 mm wide, 85 mm high, 69 mm deep, 200 g. Standards: IEC/EN 61009-1, IEC/EN 61009-2-1, OVE E 8601. Ambient air temperature -25 to 55 °C; IP20.