- ESB25-31N-03
The ABB ESB25-31N-03 is a 4-pole building contactor with a 3 NO + 1 NC main contact configuration and no auxiliary contacts. It measures 36 mm wide, 85 mm high, and 65 mm deep, with a net weight of 0.245 kg. The main circuit is rated 220 V DC and 400 V AC; rated control circuit voltage is 48 V. Rated operational current AC-1 is 25 A for both NO and NC contacts. AC-3 ratings include 9 A at 400 V three-phase, with 4 kW rated operational power. Rated insulation voltage is 500 V and rated impulse withstand voltage is 6 kV. Degree of protection is IP20, pollution degree 3, and mechanical durability is 1,000,000 cycles. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 61095, UL 60947-1, and UL 60947-4-1.
- ESB25-31N-04
ABB ESB25-31N-04 building contactor with four poles: three main contacts NO and one main contact NC, no auxiliary contacts. Rated operational current AC-1 is 25 A for both NO and NC. Rated operational voltage is 220 V DC and 400 V AC on the main circuit; rated control circuit voltage is 110 to 120 V. Rated frequency covers 50 Hz, 60 Hz, 400 Hz, and DC on the control circuit, and 50 Hz, 60 Hz, and DC on the main circuit. Dimensions are 36 mm wide, 85 mm high, and 65 mm deep, weight 0.24 kg. Rated insulation voltage 500 V, rated impulse withstand voltage 6 kV, degree of protection IP20, pollution degree 3. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 61095, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L.
- ESB25-31N-06
The ABB ESB25-31N-06 is a four-pole building contactor with three normally open main contacts and one normally closed main contact. It measures 36 mm wide, 85 mm high, and 65 mm deep, with a net weight of 0.235 kg, and occupies two modular spacings. The main circuit is rated 220 V DC and 400 V AC; control circuit voltage is 230 to 240 V. Rated operational current is 25 A for AC-1 and AC-7a, and 9 A at 400 V three-phase for AC-3 and AC-7b. Rated insulation voltage is 500 V and rated impulse withstand voltage is 6 kV. Degree of protection is IP20, pollution degree 3, and mechanical durability is 1,000,000 cycles. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 61095, UL 60947-1, and UL 60947-4-1.
- ESB25-31N-07
The ABB ESB25-31N-07 is a four-pole building contactor with three normally open main contacts and one normally closed main contact. It measures 36 mm wide, 85 mm high, and 65 mm deep, weighing 0.235 kg, and occupies 2.0 modular spacings. Rated operational voltage is 220 V DC and 400 V AC for the main circuit; rated control circuit voltage is 400 to 415 V. Rated operational current AC-1 is 25 A for both NO and NC contacts. Rated insulation voltage is 500 V and rated impulse withstand voltage is 6 kV. Degree of protection is IP20, pollution degree 3, with a mechanical durability of 1,000,000 cycles. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 61095, UL 60947-1, and UL 60947-4-1.
- ESB25-31N-14
ABB building contactor ESB25-31N-14, manufacturer ID 1SAE231111M1431. Four-pole device with three main NO contacts and one main NC contact, rated operational current 25 A at AC-1 for both NO and NC. Rated operational voltage is 220 V DC and 400 V AC on the main circuit; rated control circuit voltage is 12 V. Rated insulation voltage 500 V, rated impulse withstand voltage 6 kV, pollution degree 3, degree of protection IP20. Dimensions are 36 mm wide, 85 mm high, and 65 mm deep, with a net weight of 0.245 kg. Main circuit connecting capacity accepts rigid conductors from 1.5 to 10 mm². Mechanical durability is 1,000,000 cycles. Ambient air temperature for operation is -25 to +55 °C. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, and IEC/EN 61095.
- ESB25-40N-01
ABB ESB25-40N-01 building contactor, manufacturer ID 1SAE231111R0140. Four-pole (4 NO main contacts, no NC main or auxiliary contacts), 2 modular spacings wide. Rated operational voltage: main circuit 220 V DC and 400 V AC; rated control circuit voltage 24 V. Rated operational current AC-1 (NO) 25 A; AC-3 (NO) 9 A at 230 V single phase and 9 A at 400 V three phase. Rated operational power AC-1 (NO) 5.8 kW at 230 V single phase and 17.3 kW at 400 V three phase; AC-3 (NO) 1.3 kW and 4 kW respectively. Rated insulation voltage 500 V, rated impulse withstand voltage 6 kV, pollution degree 3, IP20. Dimensions 36 x 85 x 65 mm, 0.245 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 61095, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L.
- ESB25-40N-02
ABB building contactor ESB25-40N-02, manufacturer ID 1SAE231111M0240. Four-pole installation contactor with four normally open main contacts, no auxiliary contacts. Rated operational current 25 A at AC-1 and AC-7a; 9 A at AC-3 and AC-7b at 230 V single-phase and 400 V three-phase. Rated operational voltage: main circuit 220 V DC and 400 V AC. Rated control circuit voltage 42 V. Rated insulation voltage 500 V; rated impulse withstand voltage 6 kV. Dimensions 36 mm wide, 85 mm high, 65 mm deep; net weight 0.245 kg. Degree of protection IP20. Ambient operating temperature -25 to +55 degrees C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 61095, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L.
- ESB25-40N-03
ABB building contactor ESB25-40N-03, manufacturer ID 1SAE231111M0340. Four-pole installation contactor with four normally open main contacts and no auxiliary contacts. Rated operational voltage: main circuit 220 V DC and 400 V AC. Rated control circuit voltage 48 V. Rated operational current AC-1 (NO) 25 A; AC-3 9 A at 230 V single phase and 9 A at 400 V three phase. Rated insulation voltage 500 V, rated impulse withstand voltage 6 kV, pollution degree 3. Dimensions 36 mm wide, 85 mm high, 65 mm deep; net weight 0.245 kg. IP20. Mechanical durability 1,000,000 cycles. Ambient operating temperature -25 to +55 degrees C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 61095, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L.