- ESB63-30N-06
ABB building contactor ESB63-30N-06, manufacturer ID 1SAE351111M0630. Three-pole installation contactor with three normally open main contacts and no auxiliary contacts. Rated operational current AC-1 (NO) 63 A; AC-3 (NO) 30 A at 230 V single phase and 30 A at 400 V three phase. Rated operational voltage: main circuit 220 V DC and 400 V AC. Rated control circuit voltage 230 V, with control circuit frequencies of 50 Hz, 60 Hz, 400 Hz, and DC. Rated insulation voltage 500 V; rated impulse withstand voltage 6 kV. Dimensions 54 mm wide, 85 mm high, 65 mm deep; net weight 0.385 kg. IP20. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 61095, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L.
- ESB63-30N-07
The ABB ESB63-30N-07 is a three-pole building contactor with three normally open main contacts and no auxiliary contacts. It is rated 63 A at AC-1 and 30 A at AC-3 for single-phase 230 V and three-phase 400 V, corresponding to 14.5 kW and 43.6 kW at AC-1, and 5 kW and 15 kW at AC-3. Main circuit rated operational voltage is 220 V DC or 400 V AC; rated insulation voltage is 500 V and rated impulse withstand voltage is 6 kV. Dimensions are 54 mm wide, 85 mm high, and 65 mm deep, weighing 0.385 kg. Degree of protection is IP20, with a mechanical durability of 1,000,000 cycles. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, and IEC/EN 61095.
- ESB63-31N-04
The ABB ESB63-31N-04 is a four-pole building contactor with three normally open main contacts and one normally closed main contact. It is rated 63 A AC-1 (NO) and 30 A AC-1 (NC), with AC-3 ratings of 30 A at 230 V single phase and 400 V three phase. Rated operational voltage is 220 V DC or 400 V AC main circuit, with a 110 V control circuit voltage. Dimensions are 54 mm wide, 85 mm high, and 65 mm deep, weighing 0.405 kg. It offers IP20 protection, 6 kV impulse withstand, 500 V insulation voltage, and operates from -25 to +55 °C. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 61095, UL 60947-1, and UL 60947-4-1.
- ESB63-31N-06
ABB ESB63-31N-06 building contactor, manufacturer ID 1SAE351111R0631. Four poles with three normally open main contacts and one normally closed main contact. Rated operational voltage: main circuit 220 V DC and 400 V AC. Rated control circuit voltage 230 V. Rated operational current: AC-1 63 A (NO) and 30 A (NC); AC-3 30 A at 230 V single phase and 400 V three phase. Rated operational power AC-3: 5 kW at 230 V single phase and 15 kW at 400 V three phase. Dimensions 54 mm wide, 85 mm high, 65 mm deep; net weight 0.405 kg. IP20, rated insulation voltage 500 V, impulse withstand 6 kV, pollution degree 3. Ambient operating temperature -25 to +55 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 61095, UL 60947-1, UL 60947-4-1.
- ESB63-40N-02
ABB building contactor ESB63-40N-02, manufacturer ID 1SAE351111R0240. Four-pole (4 NO main contacts, no auxiliary contacts) installation contactor for distribution boards. Main circuit rated operational voltage 220 V DC and 400 V AC; rated control circuit voltage 42 V. Rated operational current 63 A at AC-1, 63 A at AC-7a, and 30 A at AC-3 (230 V single-phase and 400 V three-phase). Rated insulation voltage 500 V, rated impulse withstand voltage 6 kV, pollution degree 3, IP20. Dimensions 54 x 85 x 65 mm, 0.405 kg, 3.0 modular spacings. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 61095, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L.
- ESB63-40N-03
ABB building contactor ESB63-40N-03, manufacturer ID 1SAE351111M0340. Four-pole (4 NO main contacts, no auxiliary contacts), rated operational current AC-1 63 A and AC-7a 63 A; AC-3 30 A at 230 V single phase and 30 A at 400 V three phase. Rated operational voltage: main circuit 220 V DC and 400 V AC. Rated control circuit voltage 48 V. Rated insulation voltage 500 V, rated impulse withstand voltage 6 kV. Dimensions 54 mm wide, 85 mm high, 65 mm deep; net weight 0.405 kg. IP20, pollution degree 3, 3.0 modular spacings. Mechanical durability 1,000,000 cycles. Ambient air temperature -25 to +55 °C operation, -40 to +80 °C storage. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 61095, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L.
- ESB63-40N-05
The ABB ESB63-40N-05 is a four-pole installation contactor for distribution boards, with four normally open main contacts and no auxiliary contacts. It is rated 63 A at AC-1 and AC-7a, and 30 A at AC-3 and AC-7b at 230 V single-phase and 400 V three-phase. Rated operational voltage is 220 V DC and 400 V AC on the main circuit, with a 240 V control circuit voltage. Dimensions are 54 mm wide, 85 mm high, and 65 mm deep, weighing 0.405 kg. It offers IP20 protection, 6 kV impulse withstand, 500 V insulation voltage, and 1,000,000 mechanical operating cycles. Applicable standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 61095, UL 60947-1, and UL 60947-4-1.
- ESB63-40N-06
ABB building contactor ESB63-40N-06, manufacturer ID 1SAE351111M0640. Four-pole installation contactor with four normally open main contacts and no auxiliary contacts. Rated operational current AC-1 (NO) 63 A; AC-3 (NO) 30 A at 230 V single phase and 30 A at 400 V three phase. Rated operational voltage: main circuit 220 V DC and 400 V AC. Rated control circuit voltage 230 V. Rated frequency: control circuit 400 Hz, 50 Hz, 60 Hz, and DC; main circuit 50 Hz, 60 Hz, and DC. Rated insulation voltage 500 V, rated impulse withstand voltage 6 kV, pollution degree 3. Dimensions 54 mm wide, 85 mm high, 65 mm deep; net weight 0.405 kg. Degree of protection IP20. Ambient air temperature -25 to +55 °C operation, -40 to +80 °C storage.