- DS201 K10 A10
ABB DS201 K10 A10 is a 1P+N residual current circuit breaker with overcurrent protection, rated 10 A and 10 mA residual current, type A. Tripping characteristic K. Rated operational voltage 240 V AC according to IEC 60898-1; rated frequency 50 to 60 Hz. Rated short-circuit capacity 6 kA; rated ultimate short-circuit breaking capacity (Icu) 10 kA; rated service short-circuit breaking capacity (Ics) 7.5 kA. Rated impulse withstand voltage (Uimp) 4 kV. Two poles, one protected pole, two modular spacings, 35 mm wide, 85 mm high, 69 mm deep, 200 g. DIN-rail mounting, screw terminals, tightening torque 2.8 N·m. Standards: IEC/EN 61009-1, IEC/EN 61009-2-1. Ambient air temperature -25 to 55 °C. Degree of protection IP20, IP40.
- DS201 K10 A30
ABB DS201 K10 A30 is a 1P+N residual current circuit breaker with overcurrent protection, Type A residual current, and K tripping characteristic. Rated current is 10 A, rated residual current 30 mA, and rated short-circuit capacity 6 kA. Rated operational voltage is 240 V AC according to IEC 60898-1; rated insulation voltage is 500 V according to IEC/EN 60664-1; rated impulse withstand voltage is 4 kV. It complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. Rated frequency is 50 to 60 Hz. Electrical endurance is 10000 cycles and mechanical endurance is 20000 cycles. It mounts on DIN rail, occupies two modular spacings, measures 35 mm wide by 85 mm high by 69 mm deep, and weighs 200 g.
- DS201 K10 A30 UL
The ABB DS201 K10 A30 UL is a 1P+N leakage protection circuit breaker with a K tripping characteristic and Type A residual current detection. It has a rated current of 10 A, a rated residual current of 30 mA, and a rated short-circuit capacity of 6 kA. Rated operational voltage is 240 V according to IEC 60898-1, with a rated frequency of 50 to 60 Hz. It is a two-pole device with one protected pole, DIN-rail mounting, screw terminals, and a tightening torque of 2.8 N·m. It measures 35 mm wide, 85 mm high, and 69 mm deep, and weighs 200 g. Standards listed are IEC 61009-1, IEC 61009-2-1, UL 1053, UL 1077, and CSA C22.2 No. 235.
- DS201 K10 A300
The ABB DS201 K10 A300 is a 1P+N residual current circuit breaker (RCBO) with a rated current of 10 A and rated residual current of 300 mA, Type A. It has a K tripping characteristic and is rated for 240 V AC operation according to IEC 60898-1, with a rated frequency of 50 to 60 Hz. Rated short-circuit capacity is 6 kA, rated ultimate short-circuit breaking capacity is 10 kA, and rated service short-circuit breaking capacity is 7.5 kA. It complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. The device mounts on DIN rail, occupies two modular spacings, measures 35 mm wide by 85 mm high by 69 mm deep, and weighs 200 g. Screw terminals accept conductors from 0.75 to 25 mm², with 2.8 N·m tightening torque. Operating ambient temperature is -25 to 55 °C.
- DS201 K13 A10
The ABB DS201 K13 A10 is a 1P+N residual current operated circuit breaker with overcurrent protection, rated 13 A and 10 mA residual current, type A. It has a K tripping characteristic and is rated for 240 V AC operation according to IEC 60898-1, with a rated insulation voltage of 500 V per IEC/EN 60664-1 and a rated impulse withstand voltage of 4 kV. Rated short-circuit capacity is 6 kA, rated ultimate short-circuit breaking capacity is 10 kA, and rated service short-circuit breaking capacity is 7.5 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. The device is 35 mm wide, 85 mm high, and 69 mm deep, weighs 200 g, mounts on DIN rail, and operates from -25 to 55 °C.
- DS201 K13 A30
ABB DS201 K13 A30 is a 2-pole leakage protection circuit breaker with one protected pole, rated 13 A and 30 mA Type A residual current, K tripping characteristic. It is rated 240 V AC according to IEC 60898-1, with 500 V rated insulation voltage according to IEC/EN 60664-1, 4 kV rated impulse withstand voltage, and 50 to 60 Hz rated frequency. Short-circuit ratings include 6 kA rated short-circuit capacity, 10 kA Icu, 7.5 kA Ics, and 10 kA Inc. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. DIN-Rail mounting, screw terminals, 35 mm width, 85 mm height, 69 mm depth, 200 g net weight. Operating ambient air temperature is -25 to 55 degrees C.
- DS201 K13 A30 UL
ABB DS201 K13 A30 UL is a two-pole leakage protection circuit breaker with one protected pole, rated current 13 A, rated residual current 30 mA, and Type A residual current. Tripping characteristic is K. It is rated 240 V according to IEC 60898-1 and operates at 50 to 60 Hz. Rated short-circuit capacity is 6 kA; rated service short-circuit breaking capacity is 7.5 kA. Standards listed are IEC 61009-1, IEC 61009-2-1, UL 1053, UL 1077, and CSA C22.2 N0. 235. It mounts on DIN rail, uses screw terminals with 2.8 N·m tightening torque, and has dimensions 35 mm wide, 85 mm high, and 69 mm deep.
- DS201 K13 A300
The ABB DS201 K13 A300 is a 1P+N leakage protection circuit breaker (RCBO) with a K tripping characteristic and Type A residual current detection. It is rated 13 A at 240 V AC, with a rated residual current of 300 mA, rated short-circuit capacity of 6 kA, and rated ultimate short-circuit breaking capacity (Icu) of 10 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. The device has two poles, occupies two DIN-rail modular spacings (35 mm wide, 85 mm high, 69 mm deep), and uses screw terminals with a tightening torque of 2.8 N·m. Electrical endurance is 10000 cycles and mechanical endurance is 20000 cycles. Operating ambient air temperature is -25 to 55 °C. Degree of protection is IP20/IP40.