- DS201 K13 A30
ABB DS201 K13 A30 is a 2-pole leakage protection circuit breaker with one protected pole, rated 13 A and 30 mA Type A residual current, K tripping characteristic. It is rated 240 V AC according to IEC 60898-1, with 500 V rated insulation voltage according to IEC/EN 60664-1, 4 kV rated impulse withstand voltage, and 50 to 60 Hz rated frequency. Short-circuit ratings include 6 kA rated short-circuit capacity, 10 kA Icu, 7.5 kA Ics, and 10 kA Inc. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. DIN-Rail mounting, screw terminals, 35 mm width, 85 mm height, 69 mm depth, 200 g net weight. Operating ambient air temperature is -25 to 55 degrees C.
- DS201 K13 A30 UL
ABB DS201 K13 A30 UL is a two-pole leakage protection circuit breaker with one protected pole, rated current 13 A, rated residual current 30 mA, and Type A residual current. Tripping characteristic is K. It is rated 240 V according to IEC 60898-1 and operates at 50 to 60 Hz. Rated short-circuit capacity is 6 kA; rated service short-circuit breaking capacity is 7.5 kA. Standards listed are IEC 61009-1, IEC 61009-2-1, UL 1053, UL 1077, and CSA C22.2 N0. 235. It mounts on DIN rail, uses screw terminals with 2.8 N·m tightening torque, and has dimensions 35 mm wide, 85 mm high, and 69 mm deep.
- DS201 K13 A300
The ABB DS201 K13 A300 is a 1P+N leakage protection circuit breaker (RCBO) with a K tripping characteristic and Type A residual current detection. It is rated 13 A at 240 V AC, with a rated residual current of 300 mA, rated short-circuit capacity of 6 kA, and rated ultimate short-circuit breaking capacity (Icu) of 10 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. The device has two poles, occupies two DIN-rail modular spacings (35 mm wide, 85 mm high, 69 mm deep), and uses screw terminals with a tightening torque of 2.8 N·m. Electrical endurance is 10000 cycles and mechanical endurance is 20000 cycles. Operating ambient air temperature is -25 to 55 °C. Degree of protection is IP20/IP40.
- DS201 K16 A10
ABB DS201 K16 A10 is a leakage protection circuit breaker with a rated current of 16 A and rated residual current of 10 mA, Type A. It has a K tripping characteristic and one protected pole in a two-pole device. Rated operational voltage is 240 V AC according to IEC 60898-1, rated insulation voltage is 500 V according to IEC/EN 60664-1, and rated impulse withstand voltage is 4 kV. Rated short-circuit capacity is 6 kA; rated ultimate short-circuit breaking capacity is 10 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. Screw terminals accept conductors from 0.75 to 25 mm². DIN-rail mounting, 35 mm wide, 85 mm high, 69 mm deep, 200 g.
- DS201 K16 A30
The ABB DS201 K16 A30 is a 1P+N residual current circuit breaker with overcurrent protection, rated 16 A and 30 mA, type A residual current, K tripping characteristic. It is a two-pole device (one protected pole) occupying two modular spacings on DIN rail, 35 mm wide, 85 mm high, 69 mm deep, 200 g. Rated operational voltage is 240 V AC per IEC 60898-1; rated insulation voltage 500 V per IEC/EN 60664-1; rated impulse withstand voltage 4 kV; dielectric test voltage 2 kV. Rated short-circuit capacity is 6 kA, rated ultimate short-circuit breaking capacity 10 kA, rated service short-circuit breaking capacity 7.5 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. Operating ambient air temperature is -25 to 55 °C. Degree of protection is IP20/IP40. Screw terminals accept conductors from 0.75 to 25 mm²; tightening torque is 2.8 N·m.
- DS201 K16 A30 UL
The ABB DS201 K16 A30 UL is a 1P+N residual current circuit breaker with overcurrent protection, rated 16 A with a 30 mA Type A residual current sensitivity. It has a K tripping characteristic and is rated for 240 V according to IEC 60898-1, with a rated frequency of 50 to 60 Hz. Rated short-circuit capacity is 6 kA, and rated service short-circuit breaking capacity is 7.5 kA. It occupies two DIN-rail module spacings, measuring 35 mm wide, 85 mm high, and 69 mm deep, and weighs 200 g. Standards referenced include IEC 61009-1, IEC 61009-2-1, UL 1053, UL 1077, and CSA C22.2 No. 235. Operating ambient air temperature is -25 to 55 degrees C.
- DS201 K16 A300
The ABB DS201 K16 A300 is a 1P+N leakage protection circuit breaker with a rated current of 16 A and a rated residual current of 300 mA. It has a K tripping characteristic and Type A residual current detection. Rated operational voltage is 240 V AC according to IEC 60898-1, with a rated impulse withstand voltage of 4 kV. Rated short-circuit capacity is 6 kA, rated ultimate short-circuit breaking capacity is 10 kA, and rated service short-circuit breaking capacity is 7.5 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. The device is DIN-rail mounted, occupies two modular spacings, measures 35 mm wide by 85 mm high by 69 mm deep, and weighs 200 g. Operating ambient air temperature range is -25 to 55 degrees C.
- DS201 K2 A30
ABB DS201 K2 A30 is a 1P+N residual current breaker with overcurrent protection (RCBO), Type A residual current, K tripping characteristic, rated current 2 A and rated residual current 30 mA. It is rated 240 V AC according to IEC 60898-1, with rated insulation voltage 500 V according to IEC/EN 60664-1, rated impulse withstand voltage 4 kV, and rated short-circuit capacity 6 kA. The device complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. It has two poles, one protected pole, two modular spacings, DIN-rail mounting, screw terminals, 35 mm width, 85 mm height, 69 mm depth, and 200 g net weight. Electrical endurance is 10000 cycles; mechanical endurance is 20000 cycles. Operating ambient air temperature is -25 to 55 degrees C.