- DS201 K2 A30
ABB DS201 K2 A30 is a 1P+N residual current breaker with overcurrent protection (RCBO), Type A residual current, K tripping characteristic, rated current 2 A and rated residual current 30 mA. It is rated 240 V AC according to IEC 60898-1, with rated insulation voltage 500 V according to IEC/EN 60664-1, rated impulse withstand voltage 4 kV, and rated short-circuit capacity 6 kA. The device complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. It has two poles, one protected pole, two modular spacings, DIN-rail mounting, screw terminals, 35 mm width, 85 mm height, 69 mm depth, and 200 g net weight. Electrical endurance is 10000 cycles; mechanical endurance is 20000 cycles. Operating ambient air temperature is -25 to 55 degrees C.
- DS201 K2 A300
ABB DS201 K2 A300 is a 1P+N residual current circuit breaker (RCBO) with K tripping characteristic and Type A residual current. Rated current is 2 A; rated residual current is 300 mA. Rated operational voltage is 240 V AC according to IEC 60898-1, rated insulation voltage 500 V according to IEC/EN 60664-1, and rated impulse withstand voltage 4 kV. Rated short-circuit capacity is 6 kA, rated ultimate short-circuit breaking capacity 10 kA, and rated service short-circuit breaking capacity 7.5 kA. It complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. Rated frequency is 50 to 60 Hz. Mechanical endurance is 20000 cycles; electrical endurance is 10000 cycles. It mounts on DIN rail, occupies two modular spacings, measures 35 mm wide by 85 mm high by 69 mm deep, and weighs 200 g.
- DS201 K20 A30
ABB DS201 K20 A30 is a 1P+N residual current circuit breaker with overcurrent protection, rated 20 A and 30 mA Type A residual current, tripping characteristic K. It is rated 240 V AC according to IEC 60898-1, with rated insulation voltage 500 V according to IEC/EN 60664-1, rated impulse withstand voltage 4 kV, and rated short-circuit capacity 6 kA. It complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. The device has two poles, one protected pole, two modular spacings, and dimensions 35 mm width, 85 mm height, and 69 mm depth, weighing 200 g. It mounts on DIN rail, uses screw terminals with 2.8 N·m tightening torque, and operates from -25 to 55 °C.
- DS201 K20 A30 UL
The ABB DS201 K20 A30 UL is a 1P+N leakage protection circuit breaker with a rated current of 20 A and 30 mA residual current sensitivity, Type A. It has a K tripping characteristic, rated short-circuit capacity of 6 kA, and rated frequency of 50 to 60 Hz. Rated operational voltage is 240 V according to IEC 60898-1, with a rated impulse withstand voltage of 4 kV. It is a two-module DIN-rail device, 35 mm wide, 85 mm high, and 69 mm deep, with screw terminals and a tightening torque of 2.8 N·m. Standards include IEC 61009-1, IEC 61009-2-1, UL 1053, UL 1077, and CSA C22.2 No. 235.
- DS201 K20 A300
The ABB DS201 K20 A300 is a 1P+N residual current operated circuit breaker with overcurrent protection. It has a rated current of 20 A, a rated residual current of 300 mA, Type A residual current, and a K tripping characteristic. Rated operational voltage is 240 V AC according to IEC 60898-1, with a rated frequency of 50 to 60 Hz. Rated short-circuit capacity is 6 kA, rated ultimate short-circuit breaking capacity is 10 kA, and rated service short-circuit breaking capacity is 7.5 kA. It complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. The device occupies two modular spacings, measures 35 mm wide by 85 mm high by 69 mm deep, and weighs 200 g. Screw terminals accept conductors from 0.75 to 25 mm². Operating ambient air temperature range is -25 to 55 °C.
- DS201 K25 A30
ABB DS201 K25 A30 is a 1P+N residual current circuit breaker with overcurrent protection, rated 25 A and 30 mA residual current, Type A. It has a K tripping characteristic and is rated 240 V AC according to IEC 60898-1, with insulation voltage 500 V per IEC/EN 60664-1 and impulse withstand 4 kV. Short-circuit ratings include 6 kA rated capacity, 10 kA Icu, 7.5 kA Ics, and 10 kA Inc. It complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. The device occupies two DIN-rail modules, measures 35 x 85 x 69 mm, weighs 200 g, and operates from -25 to 55 degrees C. Terminals accept 0.75 to 25 square mm conductors with 2.8 N-m tightening torque.
- DS201 K25 A300
ABB DS201 K25 A300 is a 1P+N residual current circuit breaker with overcurrent protection, rated 25 A, Type A residual current 300 mA, tripping characteristic K, and rated short-circuit capacity 6 kA. Rated operational voltage is 240 V AC according to IEC 60898-1; rated impulse withstand voltage is 4 kV. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. Rated frequency is 50 to 60 Hz. It occupies two DIN-rail modules, 35 mm wide, 85 mm high, 69 mm deep, and weighs 200 g. Screw terminals accept 0.75 to 25 mm² conductors, tightening torque 2.8 N·m. Operating ambient air temperature is -25 to 55 °C. Degree of protection is IP20 and IP40.
- DS201 K4 A30
ABB DS201 K4 A30 leakage protection circuit breaker, manufacturer ID 2CSR255180R1047. It is a 1P+N RCBO with 2 poles (1 protected), K tripping characteristic, Type A residual current, rated current 4 A, and rated residual current 30 mA. Rated operational voltage is 240 V AC according to IEC 60898-1; rated frequency 50 to 60 Hz. Rated short-circuit capacity is 6 kA, rated ultimate short-circuit breaking capacity (Icu) 10 kA, and rated service short-circuit breaking capacity (Ics) 7.5 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. DIN-rail mounting, 2 modular spacings, 35 mm wide, 85 mm high, 69 mm deep, 200 g. Screw terminals, tightening torque 2.8 N·m, wire stripping length 12 mm. Operating ambient air temperature -25 to 55 °C. Degree of protection IP20/IP40.