- DS201 K25 A300
ABB DS201 K25 A300 is a 1P+N residual current circuit breaker with overcurrent protection, rated 25 A, Type A residual current 300 mA, tripping characteristic K, and rated short-circuit capacity 6 kA. Rated operational voltage is 240 V AC according to IEC 60898-1; rated impulse withstand voltage is 4 kV. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. Rated frequency is 50 to 60 Hz. It occupies two DIN-rail modules, 35 mm wide, 85 mm high, 69 mm deep, and weighs 200 g. Screw terminals accept 0.75 to 25 mm² conductors, tightening torque 2.8 N·m. Operating ambient air temperature is -25 to 55 °C. Degree of protection is IP20 and IP40.
- DS201 K4 A30
ABB DS201 K4 A30 leakage protection circuit breaker, manufacturer ID 2CSR255180R1047. It is a 1P+N RCBO with 2 poles (1 protected), K tripping characteristic, Type A residual current, rated current 4 A, and rated residual current 30 mA. Rated operational voltage is 240 V AC according to IEC 60898-1; rated frequency 50 to 60 Hz. Rated short-circuit capacity is 6 kA, rated ultimate short-circuit breaking capacity (Icu) 10 kA, and rated service short-circuit breaking capacity (Ics) 7.5 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. DIN-rail mounting, 2 modular spacings, 35 mm wide, 85 mm high, 69 mm deep, 200 g. Screw terminals, tightening torque 2.8 N·m, wire stripping length 12 mm. Operating ambient air temperature -25 to 55 °C. Degree of protection IP20/IP40.
- DS201 K4 A300
ABB DS201 K4 A300 is a 1P+N leakage protection circuit breaker with K tripping characteristic and Type A residual current. Rated current is 4 A and rated residual current is 300 mA. It is rated 240 V AC according to IEC 60898-1, with rated insulation voltage 500 V according to IEC/EN 60664-1, rated impulse withstand voltage 4 kV, and dielectric test voltage 2 kV. Rated short-circuit capacity is 6 kA; rated ultimate short-circuit breaking capacity is 10 kA, rated service short-circuit breaking capacity is 7.5 kA, and rated conditional short-circuit current is 10 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. Rated frequency is 50 to 60 Hz. It has two poles, one protected pole, DIN-rail mounting, screw terminals, 35 mm width, 85 mm height, 69 mm depth, and 200 g net weight.
- DS201 K40 A30
ABB DS201 K40 A30 is a 1P+N residual current circuit breaker (RCBO) with a K tripping characteristic and Type A residual current detection. Rated current is 40 A and rated residual current is 30 mA. Rated operational voltage is 240 V AC according to IEC 60898-1; rated insulation voltage is 500 V according to IEC/EN 60664-1 and rated impulse withstand voltage is 4 kV. Rated short-circuit capacity is 6 kA, rated ultimate short-circuit breaking capacity is 10 kA, and rated service short-circuit breaking capacity is 7.5 kA. It complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. It mounts on DIN rail, has two poles, two modular spacings, screw terminals, and dimensions 35 x 85 x 69 mm.
- DS201 K40 A300
The ABB DS201 K40 A300 is a 1P+N residual current circuit breaker (RCBO) with a K tripping characteristic and Type A residual current detection. It is rated 40 A with a 300 mA rated residual current, 240 V AC rated operational voltage per IEC 60898-1, and 50 to 60 Hz. Rated short-circuit capacity is 6 kA, rated ultimate short-circuit breaking capacity (Icu) is 10 kA, and rated service short-circuit breaking capacity (Ics) is 7.5 kA. It complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. The two-module DIN-rail device measures 35 mm wide, 85 mm high, and 69 mm deep, weighs 200 g, and operates from -25 to 55 degrees C. Screw terminals accept conductors from 0.75 to 25 square millimeters, with 2.8 N-m tightening torque.
- DS201 K6 A30
ABB DS201 K6 A30 is a 1P+N leakage protection circuit breaker (RCBO) with a K tripping characteristic and Type A residual current. It is rated 6 A, 30 mA residual current, and 240 V AC according to IEC 60898-1, with a rated short-circuit capacity of 6 kA and rated ultimate short-circuit breaking capacity (Icu) of 10 kA. It complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. The device has two poles, one protected pole, 2 modular spacings, and mounts on DIN rail. It measures 35 mm wide, 85 mm high, and 69 mm deep, weighs 200 g, and operates from -25 to 55 °C.
- DS201 K6 A300
The ABB DS201 K6 A300 is a leakage protection circuit breaker with a rated current of 6 A and a rated residual current of 300 mA. It has a K tripping characteristic and Type A residual current sensitivity. It is a two-pole device with one protected pole and occupies two modular spacings on a DIN rail. The rated operational voltage is 240 V AC according to IEC 60898-1, and the rated frequency is 50 to 60 Hz. The rated short-circuit capacity is 6 kA, and the rated ultimate short-circuit breaking capacity is 10 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. The product measures 35 mm wide, 85 mm high, and 69 mm deep, and weighs 200 g.
- DS201 K8 A30
ABB DS201 K8 A30 is a 1P+N leakage protection circuit breaker (RCBO) with a K tripping characteristic and Type A residual current. Rated current is 8 A, rated residual current 30 mA, rated operational voltage 240 V AC per IEC 60898-1, and rated frequency 50 to 60 Hz. Rated short-circuit capacity is 6 kA, rated ultimate short-circuit breaking capacity (Icu) 10 kA, and rated service short-circuit breaking capacity (Ics) 7.5 kA. It complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. The device has two poles, one protected pole, 2 modular spacings, and mounts on DIN rail. Dimensions are 35 mm width, 85 mm height, 69 mm depth, and 200 g net weight. Operating ambient air temperature is -25 to 55 degrees C.