- OS400B12P
ABB OS400B12P fuse switch disconnector, 3-pole, front-operated, base mounting, with pistol handle and shaft included. Rated current 400 A; rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV. Conventional free-air thermal current 400 A at 40 °C; enclosed thermal current 400 A. Rated conditional short-circuit current 80 kA at 690 V; short-time withstand current 14 kA rms for 1 s. Power loss 30 W per pole at rated operating conditions. Accepts B1-B4 British Standard fuses. Lug terminals, 25 mm wide, tightening torque 30 to 44 N·m. Line terminals top in/bottom out or bottom in/top out. Pollution degree 3. Standards: IEC 60947-3. Dimensions 255 x 230 x 176 mm; net weight 6.7 kg.
- OS400B21LR
ABB OS400B21LR fuse switch disconnector, 3-pole, front-operated, base mounting. Rated current 400 A; rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV. Conventional free-air thermal current 400 A at 40 °C; conventional thermal current 630 A fully enclosed. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 14 kA rms for 1 s. Fuse system British Standard, fuse size B1-B4. Line terminals left in, right out; lug terminals 25 mm wide; tightening torque 30 to 44 N·m. Power loss 40 W per pole at rated operating conditions. Pollution degree 3. Dimensions 344 mm wide, 150 mm high, 255 mm deep; 9.6 kg. Standards IEC 60947-3. Handle and shaft not included.
- OS400B21LRP
ABB fuse protector, model OS400B21LRP. Manufacturer ID 1SCA022855R1580. Three-pole, front-operated fuse switch disconnector for base mounting, with line terminals left in and right out. Rated current 400 A; rated operational voltage 690 V AC. Conventional free-air thermal current 400 A at 40 °C; conventional thermal current 400 A fully enclosed. Rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 14 kA rms for 1 s. Fuse system British Standard, fuse size B1-B4. Lug terminals, 25 mm wide, tightening torque 30 to 44 N·m. Pistol handle and shaft included. Pollution degree 3. Standards: IEC 60947-3. Dimensions 400 mm wide, 194 mm high, 201 mm deep; net weight 9.4 kg.
- OS400B22LR
ABB OS400B22LR fuse switch disconnector, four-pole, front-operated, base mounting. Rated current 400 A at 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV. Conventional free-air thermal current 400 A at 40 °C; enclosed thermal current 400 A. Rated conditional short-circuit current 80 kA at 690 V; short-time withstand current 14 kA rms for 1 s. Power loss 40 W per pole at rated operating conditions. Fuse system British Standard, fuse size B1-B4; fourth pole switched-fusible. Lug terminals, 25 mm width, tightening torque 30 to 44 N·m. Pollution degree 3. Dimensions 176 mm wide, 407 mm high, 230 mm deep; 12 kg. Conforms to IEC 60947-3. Handle and shaft not included.
- OS400B22LRP
ABB OS400B22LRP fuse switch disconnector, four-pole, front-operated, base mounting. Rated current 400 A, rated operational voltage 690 V AC, rated insulation voltage 1000 V, rated impulse withstand voltage 12 kV. Conventional free-air thermal current 400 A at 40 °C; conventional thermal current 400 A fully enclosed. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 14 kA rms for 1 s. Power loss 40 W per pole at rated operating conditions. Fuse size B1-B4, British Standard fuse system. Lug terminals, 25 mm terminal width, tightening torque 30 to 44 N·m. Pollution degree 3. Standards: IEC 60947-3. Dimensions 463 mm width, 194 mm height, 201 mm depth; net weight 11.5 kg. Pistol handle and shaft included.
- OS400B22N2P
The ABB OS400B22N2P is a four-pole front-operated fuse switch disconnector for base mounting, with a pistol handle and shaft included. It uses British Standard fuse sizes B1-B4 and accepts lug terminals 25 mm wide, tightened to 30 to 44 N·m. Rated current is 400 A in the main circuit; conventional free-air thermal current is 400 A at 40 °C, and conventional thermal current fully enclosed is 400 A. Rated operational voltage is 690 V AC, rated insulation voltage 1000 V, and rated impulse withstand voltage 12 kV. Rated conditional short-circuit current is 80 kA at 690 V, and rated short-time withstand current is 14 kA rms for 1 s. It conforms to IEC 60947-3. Dimensions are 318 mm wide, 176 mm high, and 230 mm deep; net weight is 9.1 kg.
- OS400B30P
The ABB OS400B30P is a three-pole fuse protector with a British Standard fuse system for B1-B4 fuse sizes. It is base mounted and front operated, with a pistol handle and shaft included. The main circuit is rated 400 A at 690 V AC, with a rated insulation voltage of 1000 V and a rated impulse withstand voltage of 12 kV. Conventional free-air thermal current is 400 A at 40 °C, and conventional thermal current is 400 A fully enclosed. Rated conditional short-circuit current is 80 kA at 690 V, and rated short-time withstand current is 14 kA rms for 1 s. It conforms to IEC 60947-3. Dimensions are 255 mm wide, 230 mm high, and 176 mm deep, weighing 6.73 kg.
- OS400B40N2P
ABB OS400B40N2P fuse protector, four-pole, front-operated, base mounting. Rated current 400 A; rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV. Conventional free-air thermal current 400 A at 40 °C; conventional thermal current 400 A fully enclosed. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 14 kA rms for 1 s. Power loss 30 W per pole at rated operating conditions. British Standard fuse system, fuse size B1-B4. Fourth pole switched with solid link, right side. Lug terminals, 25 mm width, tightening torque 30 to 44 N·m. Pistol handle and shaft included. Pollution degree 3. Standards: IEC 60947-3. Dimensions 319 mm width, 230 mm height, 176 mm depth; net weight 9.1 kg.