- OS400B22LRP
ABB OS400B22LRP fuse switch disconnector, four-pole, front-operated, base mounting. Rated current 400 A, rated operational voltage 690 V AC, rated insulation voltage 1000 V, rated impulse withstand voltage 12 kV. Conventional free-air thermal current 400 A at 40 °C; conventional thermal current 400 A fully enclosed. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 14 kA rms for 1 s. Power loss 40 W per pole at rated operating conditions. Fuse size B1-B4, British Standard fuse system. Lug terminals, 25 mm terminal width, tightening torque 30 to 44 N·m. Pollution degree 3. Standards: IEC 60947-3. Dimensions 463 mm width, 194 mm height, 201 mm depth; net weight 11.5 kg. Pistol handle and shaft included.
- OS400B22N2P
The ABB OS400B22N2P is a four-pole front-operated fuse switch disconnector for base mounting, with a pistol handle and shaft included. It uses British Standard fuse sizes B1-B4 and accepts lug terminals 25 mm wide, tightened to 30 to 44 N·m. Rated current is 400 A in the main circuit; conventional free-air thermal current is 400 A at 40 °C, and conventional thermal current fully enclosed is 400 A. Rated operational voltage is 690 V AC, rated insulation voltage 1000 V, and rated impulse withstand voltage 12 kV. Rated conditional short-circuit current is 80 kA at 690 V, and rated short-time withstand current is 14 kA rms for 1 s. It conforms to IEC 60947-3. Dimensions are 318 mm wide, 176 mm high, and 230 mm deep; net weight is 9.1 kg.
- OS400B30P
The ABB OS400B30P is a three-pole fuse protector with a British Standard fuse system for B1-B4 fuse sizes. It is base mounted and front operated, with a pistol handle and shaft included. The main circuit is rated 400 A at 690 V AC, with a rated insulation voltage of 1000 V and a rated impulse withstand voltage of 12 kV. Conventional free-air thermal current is 400 A at 40 °C, and conventional thermal current is 400 A fully enclosed. Rated conditional short-circuit current is 80 kA at 690 V, and rated short-time withstand current is 14 kA rms for 1 s. It conforms to IEC 60947-3. Dimensions are 255 mm wide, 230 mm high, and 176 mm deep, weighing 6.73 kg.
- OS400B40N2P
ABB OS400B40N2P fuse protector, four-pole, front-operated, base mounting. Rated current 400 A; rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV. Conventional free-air thermal current 400 A at 40 °C; conventional thermal current 400 A fully enclosed. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 14 kA rms for 1 s. Power loss 30 W per pole at rated operating conditions. British Standard fuse system, fuse size B1-B4. Fourth pole switched with solid link, right side. Lug terminals, 25 mm width, tightening torque 30 to 44 N·m. Pistol handle and shaft included. Pollution degree 3. Standards: IEC 60947-3. Dimensions 319 mm width, 230 mm height, 176 mm depth; net weight 9.1 kg.
- OS400BS30
ABB OS400BS30 fuse switch disconnector, manufacturer ID 1SCA022871R0130. Three-pole, side-operated, base-mounting unit for British Standard fuse sizes B1-B4. Rated current 400 A; rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV. Conventional free-air thermal current 400 A at 40 °C; conventional thermal current 400 A fully enclosed. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 14 kA rms for 1 s. Rated operational power AC-23A: 132 kW at 220-240 V, 220 kW at 400 V, 230 kW at 415 V, 280 kW at 500 V, 400 kW at 690 V. Power loss 30 W per pole at rated operating conditions. Lug terminals, 25 mm wide, tightening torque 30 to 44 N·m. Pollution degree 3. Standards: IEC 60947-3. Handle and shaft not included. Dimensions 288 x 230 x 176 mm; net weight 6.675 kg.
- OS400BS30K
ABB OS400BS30K fuse switch disconnector, 3-pole, side-operated, base mounting, with direct mounted handle included. Rated current 400 A; rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV. Conventional free-air thermal current 400 A at 40 °C; fully enclosed thermal current 400 A. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 14 kA rms for 1 s. Rated operational power AC-23A: 132 kW at 220–240 V, 220 kW at 400 V, 230 kW at 415 V, 280 kW at 500 V, 400 kW at 690 V. Fuse size B1–B4, British Standard fuse system. Lug terminals, 25 mm width, tightening torque 30–44 N·m. Pollution degree 3. Standards: IEC 60947-3. Dimensions 288 x 230 x 176 mm; net weight 6.82 kg.
- OS400BS40F
ABB OS400BS40F fuse protector, 4-pole side-operated switch fuse with base mounting and lug terminals. Rated current 400 A; rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV. Conventional free-air thermal current 400 A at 40 °C; conventional thermal current 400 A fully enclosed. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 14 kA rms for 1 s. Power loss 30 W per pole at rated operating conditions. Fourth pole is switched-fusible; fuse size B1-B4, British Standard fuse system. Terminal width 25 mm; tightening torque 30 to 44 N·m. Pollution degree 3. Standards: IEC 60947-3. Handle and shaft not included. Net dimensions 352 x 230 x 176 mm; net weight 8.455 kg.
- OS400BS40FK
ABB OS400BS40FK fuse switch disconnector, manufacturer ID 1SCA022871R0480. Four-pole, side-operated, base-mounting unit with switched-fusible fourth pole and a direct-mounted handle. Rated current 400 A; rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV. Conventional free-air thermal current 400 A at 40 °C; enclosed thermal current 400 A. Rated conditional short-circuit current 80 kA at 690 V; short-time withstand current 14 kA rms for 1 s. Power loss 30 W per pole at rated operating conditions. Fuse system British Standard, fuse size B1-B4. Lug terminals, 25 mm wide, tightening torque 30 to 44 N·m. Pollution degree 3. Standards: IEC 60947-3. Dimensions 352 x 230 x 176 mm; weight 8.595 kg.