- DS201 M C10 A100
ABB DS201 M C10 A100 is a 1P+N leakage protection circuit breaker (RCBO) with a C tripping characteristic and Type A residual current detection. Rated current is 10 A; rated residual current is 100 mA. Rated operational voltage is 240 V AC according to IEC 60898-1, with rated insulation voltage 500 V according to IEC/EN 60664-1 and rated impulse withstand voltage 4 kV. Rated short-circuit capacity is 10 kA, rated ultimate short-circuit breaking capacity 15 kA, and rated service short-circuit breaking capacity 11.2 kA. It complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. It mounts on DIN rail, occupies two modular spacings, and measures 35 mm wide, 85 mm high, and 69 mm deep, weighing 200 g.
- DS201 M C10 A30
The ABB DS201 M C10 A30 is a leakage protection circuit breaker with a rated current of 10 A and rated residual current of 30 mA. It has a C tripping characteristic and Type A residual current detection. Rated operational voltage is 240 V AC according to IEC 60898-1, with rated insulation voltage 500 V per IEC/EN 60664-1 and rated impulse withstand voltage 4 kV. Rated short-circuit capacity is 10 kA; rated ultimate short-circuit breaking capacity is 15 kA. It has two poles, one protected pole, and occupies two modular spacings for DIN-rail mounting. Standards: IEC/EN 61009-1 and IEC/EN 61009-2-1. Dimensions are 35 mm width, 85 mm height, 69 mm depth, 200 g net weight. Operating ambient air temperature is -25 to 55 degrees C.
- DS201 M C10 A30 110V
The ABB DS201 M C10 A30 110V is a two-module 1P+N RCBO for single-phase circuits, combining overcurrent and residual current protection. It is a Type A device with a C tripping characteristic, rated current 10 A, rated residual current 30 mA, and rated short-circuit capacity 10 kA. It conforms to IEC 61009-1 and IEC 61009-2-1. Rated operational voltage is 240 V according to IEC 60898-1; rated impulse withstand voltage is 4 kV, and rated frequency is 50 to 60 Hz. It mounts on DIN rail, has screw terminals with 2.8 N·m tightening torque, and operates from -25 to 55 °C. Dimensions are 35 mm width, 85 mm height, and 69 mm depth; weight is 200 g.
- DS201 M C10 A300
The ABB DS201 M C10 A300 is a 1P+N leakage protection circuit breaker with a rated current of 10 A and a rated residual current of 300 mA. It has a C tripping characteristic and Type A residual current detection. Rated operational voltage is 240 V AC according to IEC 60898-1, with a rated insulation voltage of 500 V per IEC/EN 60664-1 and a rated impulse withstand voltage of 4 kV. Rated short-circuit capacity is 10 kA, rated ultimate short-circuit breaking capacity is 15 kA, and rated service short-circuit breaking capacity is 11.2 kA. It complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. It measures 35 mm wide, 85 mm high, and 69 mm deep, weighs 200 g, and mounts on DIN rail. Operating ambient air temperature is -25 to 55 degrees C. Degree of protection is IP20 and IP40.
- DS201 M C10 AC100
ABB DS201 M C10 AC100 is a leakage protection circuit breaker with a C tripping characteristic and Type AC residual current detection. It has a rated current of 10 A, rated residual current of 100 mA, and rated short-circuit capacity of 10 kA. Rated operational voltage is 240 V according to IEC 60898-1, rated frequency 50 to 60 Hz. It provides one protected pole in a two-pole, two-module DIN-rail housing measuring 35 mm wide, 85 mm high, and 69 mm deep. Standards: IEC/EN 61009-1 and IEC/EN 61009-2-1. Screw terminals accept conductors up to 25 mm². Operating ambient air temperature is -25 to 55 °C. Degree of protection is IP20 and IP40.
- DS201 M C10 AC30
ABB DS201 M C10 AC30 is a two-pole leakage protection circuit breaker with one protected pole, rated 10 A and 30 mA residual current, Type AC. Tripping characteristic C. Rated operational voltage 240 V AC per IEC 60898-1; rated insulation voltage 500 V per IEC/EN 60664-1; rated impulse withstand voltage 4 kV. Rated short-circuit capacity 10 kA, rated ultimate short-circuit breaking capacity 15 kA, rated service short-circuit breaking capacity 11.2 kA. Rated frequency 50 to 60 Hz. Standards: IEC/EN 61009-1 and IEC/EN 61009-2-1. DIN-rail mounting, two modular spacings, 35 mm wide, 85 mm high, 69 mm deep, 200 g. Screw terminals, tightening torque 2.8 N·m. Operating ambient air temperature -25 to 55 °C. Degree of protection IP20, IP40.
- DS201 M C10 AC300
ABB DS201 M C10 AC300 is a 1P+N leakage protection circuit breaker with overcurrent protection. It has a rated current of 10 A, C tripping characteristic, Type AC residual current, and rated residual current of 300 mA. Rated operational voltage is 240 V AC according to IEC 60898-1; rated insulation voltage is 500 V according to IEC/EN 60664-1. Rated short-circuit capacity is 10 kA, rated ultimate short-circuit breaking capacity is 15 kA, and rated service short-circuit breaking capacity is 11.2 kA. It is rated 50 to 60 Hz, with total power loss of 2.3 W. It mounts on DIN rail with 2 modular spacings, 35 mm wide, 85 mm high, and 69 mm deep. Standards: IEC/EN 61009-1 and IEC/EN 61009-2-1.
- DS201 M C10 APR100
The ABB DS201 M C10 APR100 is a 1P+N residual current operated circuit breaker with integral overcurrent protection, rated 10 A with C tripping characteristic and 100 mA Type A residual current sensitivity. It is rated 240 V AC according to IEC 60898-1, with rated insulation voltage 500 V per IEC/EN 60664-1 and rated impulse withstand voltage 4 kV. Short-circuit ratings include 10 kA rated short-circuit capacity, 15 kA Icu, 11.2 kA Ics, and 15 kA Inc. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. The device occupies two DIN-rail modules, measures 35 mm wide by 85 mm high by 69 mm deep, weighs 200 g, and operates from -25 to 55 degrees C. Terminals accept conductors from 0.75 to 25 square millimeters.