- DS201 M C16 A10
The ABB DS201 M C16 A10 is a 1P+N residual current circuit breaker with overcurrent protection, rated 16 A with 10 mA residual current sensitivity and Type A residual current. It has a C tripping characteristic and is rated for 240 V AC operation according to IEC 60898-1, with a rated insulation voltage of 500 V according to IEC/EN 60664-1. Rated short-circuit capacity is 10 kA, rated ultimate short-circuit breaking capacity (Icu) is 15 kA, and rated service short-circuit breaking capacity (Ics) is 11.2 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. The device mounts on DIN rail, occupies two modular spacings, measures 35 mm wide, 85 mm high, and 69 mm deep, and weighs 200 g. Operating ambient air temperature range is -25 to 55 degrees C.
- DS201 M C16 A100
The ABB DS201 M C16 A100 is a 1P+N residual current circuit breaker with overcurrent protection, rated 16 A with a C tripping characteristic and 100 mA Type A residual current. It is rated 240 V AC according to IEC 60898-1 and 50 to 60 Hz, with a rated short-circuit capacity of 10 kA and rated ultimate short-circuit breaking capacity (Icu) of 15 kA. It complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. The device has two poles, one protected pole, two modular spacings, and mounts on DIN rail. Dimensions are 35 mm width, 85 mm height, and 69 mm depth, with a net weight of 200 g. Operating ambient air temperature is -25 to 55 degrees C.
- DS201 M C16 A30
ABB DS201 M C16 A30 is a 1P+N residual current circuit breaker (RCBO) for single-phase circuits. It provides overload and short-circuit protection with a C tripping characteristic and 16 A rated current, plus earth fault protection with 30 mA rated residual current, Type A. Rated operational voltage is 240 V AC according to IEC 60898-1; rated frequency 50 to 60 Hz. Rated short-circuit capacity is 10 kA, rated ultimate short-circuit breaking capacity (Icu) 15 kA, and rated service short-circuit breaking capacity (Ics) 11.2 kA. It complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. DIN-rail mounting, two module widths, 35 mm wide, 85 mm high, 69 mm deep, 200 g. Operating ambient air temperature -25 to 55 °C. Screw terminals, tightening torque 2.8 N·m.
- DS201 M C16 A30 110V
ABB DS201 M C16 A30 110V leakage protection circuit breaker, manufacturer ID 2CSR275189R1164. Rated current 16 A, rated residual current 30 mA, Type A residual current, C tripping characteristic, 1P+N with two poles and one protected pole. Rated operational voltage 240 V AC per IEC 60898-1; test voltage 110 V. Rated short-circuit capacity 10 kA, rated ultimate short-circuit breaking capacity 15 kA, rated service short-circuit breaking capacity 11.2 kA. Complies with IEC 61009-1 and IEC 61009-2-1. Rated frequency 50 to 60 Hz. Screw terminals accept 0.75 to 25 mm² conductors; tightening torque 2.8 N·m. DIN-rail mounting, two module widths, 35 mm wide, 85 mm high, 69 mm deep, 200 g. Operating ambient air temperature -25 to 55 °C. Degree of protection IP20/IP40.
- DS201 M C16 A300
ABB DS201 M C16 A300 is a 1P+N leakage protection circuit breaker (RCBO) with a C tripping characteristic and Type A residual current. It is rated 16 A, 300 mA residual current, and 240 V AC according to IEC 60898-1, with 50 to 60 Hz rated frequency. Rated short-circuit capacity is 10 kA, rated ultimate short-circuit breaking capacity is 15 kA, and rated service short-circuit breaking capacity is 11.2 kA. It complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. The device has two poles, one protected pole, two module widths, and DIN-rail mounting. Dimensions are 35 mm width, 85 mm height, and 69 mm depth; net weight is 200 g.
- DS201 M C16 AC100
The ABB DS201 M C16 AC100 is a DIN-rail mounted leakage protection circuit breaker with a C tripping characteristic and Type AC residual current detection. It has a rated current of 16 A and a rated residual current of 100 mA. Rated operational voltage is 240 V AC according to IEC 60898-1, with rated insulation voltage 500 V according to IEC/EN 60664-1 and rated impulse withstand voltage 4 kV. Rated short-circuit capacity is 10 kA, rated ultimate short-circuit breaking capacity 15 kA, and rated service short-circuit breaking capacity 11.2 kA. It is a 1P+N device with two poles, two modular spacings, and 35 mm width. Standards: IEC/EN 61009-1 and IEC/EN 61009-2-1. Rated frequency is 50 to 60 Hz. Ambient air temperature range for operation is -25 to 55 degrees C. Degree of protection is IP20 and IP40.
- DS201 M C16 AC30
ABB DS201 M C16 AC30 is a 1P+N leakage protection circuit breaker (RCBO) with C tripping characteristic and Type AC residual current. Rated current is 16 A; rated residual current is 30 mA. Rated short-circuit capacity is 10 kA, rated ultimate short-circuit breaking capacity (Icu) 15 kA, and rated service short-circuit breaking capacity (Ics) 11.2 kA. Rated operational voltage is 240 V AC according to IEC 60898-1; rated insulation voltage (Ui) is 500 V according to IEC/EN 60664-1. It has two poles, one protected pole, two modular spacings, and DIN-rail mounting. Standards: IEC/EN 61009-1 and IEC/EN 61009-2-1. Dimensions are 35 mm width, 85 mm height, 69 mm depth; net weight 200 g.
- DS201 M C16 AC300
ABB DS201 M C16 AC300 is a 1P+N residual current circuit breaker with overcurrent protection (RCBO) for single-phase circuits. It provides a rated current of 16 A with C tripping characteristic, 300 mA rated residual current, Type AC residual current, and 10 kA rated short-circuit capacity. It complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. Rated operational voltage is 240 V according to IEC 60898-1; rated insulation voltage is 500 V according to IEC/EN 60664-1. Rated frequency is 50 to 60 Hz. The device occupies two DIN-rail module spacings, measures 35 mm wide, 85 mm high, and 69 mm deep, and weighs 200 g. Screw terminals accept conductors from 0.75 to 25 mm² depending on type, with 2.8 N·m tightening torque.