- DS201 M C16 A30 110V
ABB DS201 M C16 A30 110V leakage protection circuit breaker, manufacturer ID 2CSR275189R1164. Rated current 16 A, rated residual current 30 mA, Type A residual current, C tripping characteristic, 1P+N with two poles and one protected pole. Rated operational voltage 240 V AC per IEC 60898-1; test voltage 110 V. Rated short-circuit capacity 10 kA, rated ultimate short-circuit breaking capacity 15 kA, rated service short-circuit breaking capacity 11.2 kA. Complies with IEC 61009-1 and IEC 61009-2-1. Rated frequency 50 to 60 Hz. Screw terminals accept 0.75 to 25 mm² conductors; tightening torque 2.8 N·m. DIN-rail mounting, two module widths, 35 mm wide, 85 mm high, 69 mm deep, 200 g. Operating ambient air temperature -25 to 55 °C. Degree of protection IP20/IP40.
- DS201 M C16 A300
ABB DS201 M C16 A300 is a 1P+N leakage protection circuit breaker (RCBO) with a C tripping characteristic and Type A residual current. It is rated 16 A, 300 mA residual current, and 240 V AC according to IEC 60898-1, with 50 to 60 Hz rated frequency. Rated short-circuit capacity is 10 kA, rated ultimate short-circuit breaking capacity is 15 kA, and rated service short-circuit breaking capacity is 11.2 kA. It complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. The device has two poles, one protected pole, two module widths, and DIN-rail mounting. Dimensions are 35 mm width, 85 mm height, and 69 mm depth; net weight is 200 g.
- DS201 M C16 AC100
The ABB DS201 M C16 AC100 is a DIN-rail mounted leakage protection circuit breaker with a C tripping characteristic and Type AC residual current detection. It has a rated current of 16 A and a rated residual current of 100 mA. Rated operational voltage is 240 V AC according to IEC 60898-1, with rated insulation voltage 500 V according to IEC/EN 60664-1 and rated impulse withstand voltage 4 kV. Rated short-circuit capacity is 10 kA, rated ultimate short-circuit breaking capacity 15 kA, and rated service short-circuit breaking capacity 11.2 kA. It is a 1P+N device with two poles, two modular spacings, and 35 mm width. Standards: IEC/EN 61009-1 and IEC/EN 61009-2-1. Rated frequency is 50 to 60 Hz. Ambient air temperature range for operation is -25 to 55 degrees C. Degree of protection is IP20 and IP40.
- DS201 M C16 AC30
ABB DS201 M C16 AC30 is a 1P+N leakage protection circuit breaker (RCBO) with C tripping characteristic and Type AC residual current. Rated current is 16 A; rated residual current is 30 mA. Rated short-circuit capacity is 10 kA, rated ultimate short-circuit breaking capacity (Icu) 15 kA, and rated service short-circuit breaking capacity (Ics) 11.2 kA. Rated operational voltage is 240 V AC according to IEC 60898-1; rated insulation voltage (Ui) is 500 V according to IEC/EN 60664-1. It has two poles, one protected pole, two modular spacings, and DIN-rail mounting. Standards: IEC/EN 61009-1 and IEC/EN 61009-2-1. Dimensions are 35 mm width, 85 mm height, 69 mm depth; net weight 200 g.
- DS201 M C16 AC300
ABB DS201 M C16 AC300 is a 1P+N residual current circuit breaker with overcurrent protection (RCBO) for single-phase circuits. It provides a rated current of 16 A with C tripping characteristic, 300 mA rated residual current, Type AC residual current, and 10 kA rated short-circuit capacity. It complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. Rated operational voltage is 240 V according to IEC 60898-1; rated insulation voltage is 500 V according to IEC/EN 60664-1. Rated frequency is 50 to 60 Hz. The device occupies two DIN-rail module spacings, measures 35 mm wide, 85 mm high, and 69 mm deep, and weighs 200 g. Screw terminals accept conductors from 0.75 to 25 mm² depending on type, with 2.8 N·m tightening torque.
- DS201 M C16 APR100
The ABB DS201 M C16 APR100 is a leakage protection circuit breaker with a rated current of 16 A and a rated residual current of 100 mA. It is a Type A residual current device with tripping characteristic C and an instantaneous APR high-immunity operating characteristic. It complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. Rated operational voltage is 240 V AC according to IEC 60898-1; rated insulation voltage is 500 V according to IEC/EN 60664-1. Rated short-circuit capacity is 10 kA, rated ultimate short-circuit breaking capacity is 15 kA, and rated service short-circuit breaking capacity is 11.2 kA. It has two poles, one protected pole, and occupies two modular spacings. It mounts on DIN rail and has screw terminals with a tightening torque of 2.8 N·m. Operating ambient air temperature is -25 to 55 °C.
- DS201 M C16 APR30
ABB DS201 M C16 APR30 is a 1P+N leakage protection circuit breaker (RCBO) with 16 A rated current, C tripping characteristic, and 30 mA Type A residual current. It has two poles, one protected pole, and occupies two DIN-rail modular spacings. Rated operational voltage is 240 V AC according to IEC 60898-1; rated insulation voltage is 500 V according to IEC/EN 60664-1. Rated short-circuit capacity is 10 kA, rated ultimate short-circuit breaking capacity is 15 kA, and rated service short-circuit breaking capacity is 11.2 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. Rated frequency is 50 to 60 Hz. Operating ambient air temperature is -25 to 55 degrees C. Dimensions are 35 mm width, 85 mm height, and 69 mm depth; net weight is 200 g.
- DS201 M C16 APR300
ABB DS201 M C16 APR300 is a 1P+N leakage protection circuit breaker with a rated current of 16 A and rated residual current of 300 mA, Type A. Tripping characteristic C. Rated operational voltage 240 V AC per IEC 60898-1; rated insulation voltage 500 V per IEC/EN 60664-1; rated impulse withstand voltage 4 kV. Rated short-circuit capacity 10 kA; rated ultimate short-circuit breaking capacity 15 kA; rated service short-circuit breaking capacity 11.2 kA. Rated frequency 50 to 60 Hz. Two-module DIN-rail mounting, 35 mm wide, 85 mm high, 69 mm deep, 200 g. Screw terminals, tightening torque 2.8 N·m, wire stripping length 12 mm. Operating ambient air temperature -25 to 55 °C. Standards: IEC/EN 61009-1, IEC/EN 61009-2-1.