- DS201 B10 G30
The ABB DS201 B10 G30 is a 1P+N residual current circuit breaker with overcurrent protection (RCBO) for single-phase circuits. It has a rated current of 10 A, B tripping characteristic, and 30 mA rated residual current, Type A/G. Rated operational voltage is 230 V AC per IEC 60898-1; rated frequency 50 to 60 Hz. Rated short-circuit capacity is 6 kA, rated ultimate short-circuit breaking capacity (Icu) 10 kA, and rated service short-circuit breaking capacity (Ics) 7.5 kA. It is rated to IEC/EN 61009-1, IEC/EN 61009-2-1, and OVE E 8601. It mounts on DIN rail with two module spacings, 35 mm wide, 85 mm high, 69 mm deep, and weighs 200 g. Operating ambient air temperature is -25 to 55 degrees C.
- DS201 B13 A10
ABB DS201 B13 A10 leakage protection circuit breaker, manufacturer ID 2CSR255180R0135. It has a B tripping characteristic, Type A residual current, 13 A rated current, and 10 mA rated residual current. Rated operational voltage is 240 V AC according to IEC 60898-1; rated insulation voltage is 500 V according to IEC/EN 60664-1. Rated short-circuit capacity is 6 kA, rated ultimate short-circuit breaking capacity is 10 kA, and rated service short-circuit breaking capacity is 7.5 kA. It has two poles, one protected pole, and two modular spacings. Standards: IEC/EN 61009-1 and IEC/EN 61009-2-1. Dimensions are 35 mm width, 85 mm height, 69 mm depth; weight 200 g. DIN-rail mounting, screw terminals, operating ambient air temperature -25 to 55 °C.
- DS201 B13 A100
The ABB DS201 B13 A100 is a 1P+N RCBO for single-phase circuits, combining overload and short-circuit protection with residual current detection. It has a rated current of 13 A, a rated residual current of 100 mA, Type A residual current, and B tripping characteristic. Rated operational voltage is 240 V AC according to IEC 60898-1; rated insulation voltage is 500 V according to IEC/EN 60664-1. Rated short-circuit capacity is 6 kA, rated ultimate short-circuit breaking capacity is 10 kA, and rated service short-circuit breaking capacity is 7.5 kA. It is rated 50 to 60 Hz and conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. It mounts on DIN rail, occupies two modular spacings, and measures 35 mm wide, 85 mm high, and 69 mm deep.
- DS201 B13 A30
The ABB DS201 B13 A30 is a 1P+N residual current circuit breaker with overcurrent protection. It has a rated current of 13 A, a rated residual current of 30 mA, Type A residual current, and B tripping characteristic. Rated short-circuit capacity is 6 kA; rated ultimate short-circuit breaking capacity (Icu) is 10 kA and rated service short-circuit breaking capacity (Ics) is 7.5 kA. Rated operational voltage is 240 V AC according to IEC 60898-1, rated frequency 50 to 60 Hz, and rated impulse withstand voltage 4 kV. It is a DIN-rail device, 2 modular spacings wide, 35 mm wide, 85 mm high, and 69 mm deep, with screw terminals and a tightening torque of 2.8 N·m. Standards: IEC 61009-1, EN 61009-1, IEC 61009-2-1, EN 61009-2-1.
- DS201 B13 A30 UL
The ABB DS201 B13 A30 UL is a 1P+N leakage protection circuit breaker with a rated current of 13 A and a rated residual current of 30 mA. It has a B tripping characteristic and Type A residual current detection. Rated operational voltage is 240 V according to IEC 60898-1, rated frequency 50 to 60 Hz, and rated short-circuit capacity 6 kA. It is a 2-pole device with one protected pole, occupying two modular spacings on a DIN rail. Dimensions are 35 mm width, 85 mm height, and 69 mm depth, with a net weight of 200 g. Screw terminals accept rigid and flexible conductors up to 25 mm². Standards listed include IEC 61009-1, IEC 61009-2-1, UL 1053, UL 1077, and CSA C22.2 No. 235.
- DS201 B13 A300
The ABB DS201 B13 A300 is a 1P+N leakage protection circuit breaker with a B tripping characteristic and Type A residual current detection. It has a rated current of 13 A and a rated residual current of 300 mA. Rated short-circuit capacity is 6 kA, with a rated ultimate short-circuit breaking capacity (Icu) of 10 kA and a rated service short-circuit breaking capacity (Ics) of 7.5 kA. It operates at 50 to 60 Hz and is rated for 240 V AC according to IEC 60898-1. The device complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. It measures 35 mm wide, 85 mm high, and 69 mm deep, weighs 200 g, mounts on DIN rail, and has screw terminals.
- DS201 B13 AC100
ABB DS201 B13 AC100 is a 1P+N residual current circuit breaker (RCBO) with two poles and one protected pole. It is rated 13 A, 240 V AC according to IEC 60898-1, with Type AC residual current and 100 mA rated residual current. Tripping characteristic is B. Rated short-circuit capacity is 6 kA; rated ultimate short-circuit breaking capacity (Icu) is 10 kA; rated service short-circuit breaking capacity (Ics) is 7.5 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. Rated frequency is 50 to 60 Hz. Mechanical endurance is 20000 cycles and electrical endurance is 10000 cycles. It mounts on DIN rail, has screw terminals, 35 mm width, 85 mm height, 69 mm depth, and 200 g net weight.
- DS201 B13 AC30
The ABB DS201 B13 AC30 is a 1P+N leakage protection circuit breaker with a rated current of 13 A and a rated residual current of 30 mA. It has a B tripping characteristic and Type AC residual current. Rated operational voltage is 240 V AC according to IEC 60898-1, with a rated insulation voltage of 500 V according to IEC/EN 60664-1 and a rated impulse withstand voltage of 4 kV. Rated short-circuit capacity is 6 kA, rated ultimate short-circuit breaking capacity is 10 kA, and rated service short-circuit breaking capacity is 7.5 kA. It is rated 50 to 60 Hz, has two poles with one protected pole, mounts on DIN rail, and measures 35 mm wide, 85 mm high, and 69 mm deep. Standards: IEC/EN 61009-1 and IEC/EN 61009-2-1.