- DS201 B13 A30 UL
The ABB DS201 B13 A30 UL is a 1P+N leakage protection circuit breaker with a rated current of 13 A and a rated residual current of 30 mA. It has a B tripping characteristic and Type A residual current detection. Rated operational voltage is 240 V according to IEC 60898-1, rated frequency 50 to 60 Hz, and rated short-circuit capacity 6 kA. It is a 2-pole device with one protected pole, occupying two modular spacings on a DIN rail. Dimensions are 35 mm width, 85 mm height, and 69 mm depth, with a net weight of 200 g. Screw terminals accept rigid and flexible conductors up to 25 mm². Standards listed include IEC 61009-1, IEC 61009-2-1, UL 1053, UL 1077, and CSA C22.2 No. 235.
- DS201 B13 A300
The ABB DS201 B13 A300 is a 1P+N leakage protection circuit breaker with a B tripping characteristic and Type A residual current detection. It has a rated current of 13 A and a rated residual current of 300 mA. Rated short-circuit capacity is 6 kA, with a rated ultimate short-circuit breaking capacity (Icu) of 10 kA and a rated service short-circuit breaking capacity (Ics) of 7.5 kA. It operates at 50 to 60 Hz and is rated for 240 V AC according to IEC 60898-1. The device complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. It measures 35 mm wide, 85 mm high, and 69 mm deep, weighs 200 g, mounts on DIN rail, and has screw terminals.
- DS201 B13 AC100
ABB DS201 B13 AC100 is a 1P+N residual current circuit breaker (RCBO) with two poles and one protected pole. It is rated 13 A, 240 V AC according to IEC 60898-1, with Type AC residual current and 100 mA rated residual current. Tripping characteristic is B. Rated short-circuit capacity is 6 kA; rated ultimate short-circuit breaking capacity (Icu) is 10 kA; rated service short-circuit breaking capacity (Ics) is 7.5 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. Rated frequency is 50 to 60 Hz. Mechanical endurance is 20000 cycles and electrical endurance is 10000 cycles. It mounts on DIN rail, has screw terminals, 35 mm width, 85 mm height, 69 mm depth, and 200 g net weight.
- DS201 B13 AC30
The ABB DS201 B13 AC30 is a 1P+N leakage protection circuit breaker with a rated current of 13 A and a rated residual current of 30 mA. It has a B tripping characteristic and Type AC residual current. Rated operational voltage is 240 V AC according to IEC 60898-1, with a rated insulation voltage of 500 V according to IEC/EN 60664-1 and a rated impulse withstand voltage of 4 kV. Rated short-circuit capacity is 6 kA, rated ultimate short-circuit breaking capacity is 10 kA, and rated service short-circuit breaking capacity is 7.5 kA. It is rated 50 to 60 Hz, has two poles with one protected pole, mounts on DIN rail, and measures 35 mm wide, 85 mm high, and 69 mm deep. Standards: IEC/EN 61009-1 and IEC/EN 61009-2-1.
- DS201 B13 AC300
ABB DS201 B13 AC300 is a leakage protection circuit breaker (RCBO) with overcurrent protection, Type AC residual current, B tripping characteristic, 13 A rated current, and 300 mA rated residual current. It is a two-pole device with one protected pole, 2 modular spacings, and DIN-rail mounting. Rated operational voltage is 240 V AC according to IEC 60898-1; rated insulation voltage is 500 V according to IEC/EN 60664-1. Rated short-circuit capacity is 6 kA, rated ultimate short-circuit breaking capacity is 10 kA, and rated service short-circuit breaking capacity is 7.5 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. Electrical endurance is 10000 cycles and mechanical endurance is 20000 cycles. Terminal tightening torque is 2.8 N·m; wire stripping length is 12 mm. Operating ambient air temperature is -25 to 55 °C.
- DS201 B13 G30
The ABB DS201 B13 G30 is a 1P+N leakage protection circuit breaker with a B tripping characteristic and Type A/G residual current detection. It has a rated current of 13 A and a rated residual current of 30 mA. Rated operational voltage is 240 V AC according to IEC 60898-1; rated insulation voltage is 500 V according to IEC/EN 60664-1. Rated short-circuit capacity is 6 kA, rated ultimate short-circuit breaking capacity is 10 kA, and rated service short-circuit breaking capacity is 7.5 kA. It complies with IEC/EN 61009-1, IEC/EN 61009-2-1, and OVE E 8601. It mounts on DIN rail, occupies two modular spacings, and measures 35 mm wide, 85 mm high, and 69 mm deep.
- DS201 B16 A10
ABB DS201 B16 A10 is a 1P+N leakage protection circuit breaker with B tripping characteristic and Type A residual current. It has a rated current of 16 A, rated residual current of 10 mA, and rated operational voltage of 240 V AC according to IEC 60898-1. Rated ultimate short-circuit breaking capacity (Icu) is 10 kA; rated service short-circuit breaking capacity (Ics) is 7.5 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. It mounts on DIN rail, occupies two modular spacings, and measures 35 mm wide, 85 mm high, and 69 mm deep. Ambient air operating temperature range is -25 to 55 °C. Degree of protection is IP20/IP40.
- DS201 B16 A100
The ABB DS201 B16 A100 is a 1P+N residual current circuit breaker with overcurrent protection. It has a rated current of 16 A, a rated residual current of 100 mA, and Type A residual current sensitivity. The tripping characteristic is B. Rated operational voltage is 240 V AC according to IEC 60898-1. It is rated 6 kA short-circuit capacity and 10 kA ultimate short-circuit breaking capacity. It complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. It occupies two DIN-rail modules, with dimensions 35 mm wide, 85 mm high, and 69 mm deep. Screw terminals accept conductors from 0.75 to 25 mm². Operating ambient temperature range is -25 to 55 °C. Degree of protection is IP20.