- KC6-31Z-P-04
ABB KC6-31Z-P-04 mini contactor relay, 4-pole, with 3 NO and 1 NC auxiliary contacts. Rated control circuit voltage 110 to 125 V DC; average pull-in and holding coil consumption 3.5 W DC. Coil operating limits per IEC 60947-5-1 for DC supply are 0.85 to 1.1 x Uc at ambient temperatures up to 55 °C. Auxiliary circuit ratings include 6 A conventional free-air thermal current, 690 V AC rated operational voltage, 6 kV rated impulse withstand voltage, and AC-15 4 A at 24, 120, and 240 V and 3 A at 400 V. Terminals are soldering pins, IP20. DIN-rail mounting per IEC 60715 for TH35-15 and TH35-7.5 rail. Dimensions 47.5 x 51.5 x 45.5 mm, 0.17 kg. Operating ambient -25 to +55 °C.
- KC6-31Z-P-1.4-81
ABB KC6-31Z-P-1.4-81 is an interface mini contactor relay with four poles, three auxiliary NO contacts and one auxiliary NC contact. The coil is rated 24 V DC with average pull-in and holding consumption of 1.4 W; coil operating limits are 0.85 to 1.1 x Uc for DC supply at temperatures up to 55 °C. Terminals are soldering pins, and mounting is DIN-rail or PCB, compatible with TH35-15 and TH35-7.5 rails per IEC 60715. Rated insulation voltage is 690 V, rated impulse withstand voltage 6 kV, and conventional free-air thermal current 6 A. Mechanical durability is 10,000,000 cycles. Dimensions are 47.5 mm width, 51.5 mm depth and 45.5 mm height, weight 0.17 kg. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1 and UL 60947-4-1.
- KC6-40E-01
ABB KC6-40E-01 mini contactor relay with 4 poles and 4 NO auxiliary contacts, no NC contacts. Coil rated 24 V DC, with average pull-in and holding consumption of 3.5 W. Coil operating limits per IEC 60947-5-1 for DC supply are 0.85 to 1.1 x Uc at up to 55 °C. Dimensions are 52.5 mm W x 46.5 mm D x 57.5 mm H, net weight 0.175 kg. DIN-rail mounting on TH35-15 or TH35-7.5 rail per IEC 60715, or screw mounting. Screw terminals accept rigid 1 to 4 mm² and flexible 1 to 2.5 mm² conductors. Ambient operating temperature -25 to +55 °C, storage -40 to +80 °C. Mechanical durability 10,000,000 cycles. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.
- KC6-40E-03
The ABB KC6-40E-03 is a 4-pole mini contactor relay with four normally open auxiliary contacts and no normally closed contacts. It has a rated control circuit voltage of 60 V DC and average pull-in and holding coil consumption of 3.5 W DC. Coil operating limits are 0.85 to 1.1 x Uc for DC supply according to IEC 60947-5-1 at temperatures up to 55 °C. Rated operational current is 4 A at 24, 120, and 240 V AC-15, 3 A at 400 V AC-15, and 2.5 A at 24 V DC-13. Mechanical durability is 10,000,000 cycles. The relay measures 52.5 mm wide, 46.5 mm deep, and 57.5 mm high, weighs 0.175 kg, and mounts on DIN rail per IEC 60715.
- KC6-40E-04
ABB KC6-40E-04 mini contactor relay, 4-pole, with 4 NO auxiliary contacts and no NC contacts. Coil rated 110 to 125 V DC; average pull-in and holding values are 3.5 W DC. Coil operating limits per IEC 60947-5-1 for DC supply are 0.85 to 1.1 x Uc at temperatures up to 55 °C. Screw terminals accept rigid conductors 1 to 4 mm² and flexible conductors 1 to 2.5 mm². Dimensions are 52.5 mm wide, 46.5 mm deep, and 57.5 mm high; net weight 0.175 kg. DIN-rail mounting per IEC 60715 (TH35-15 or TH35-7.5). Mechanical durability is 10,000,000 cycles. Ambient operating temperature -25 to +55 °C. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.
- KC6-40E-05
ABB KC6-40E-05 mini contactor relay with 4 poles and 4 NO auxiliary contacts, no NC contacts. Coil rated 220 to 240 V DC; average pull-in and holding consumption 3.5 W DC. Coil operating limits per IEC 60947-5-1 for DC supply are 0.85 to 1.1 x Uc at ambient temperatures up to 55 °C. Rated operational current AC-15 is 4 A at 24 V, 120 V and 240 V, 3 A at 400 V, and 2 A at 500 V; DC-13 is 2.5 A at 24 V, 0.7 A at 110 V, and 0.4 A at 220/240 V. Screw terminals accept rigid conductors 1 to 4 mm² and flexible conductors 1 to 2.5 mm². DIN-rail mounting per IEC 60715. Dimensions 52.5 x 46.5 x 57.5 mm, 0.175 kg. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1 and UL 60947-4-1.
- KC6-40E-06
ABB intermediate relay KC6-40E-06, mini contactor relay with four poles and four normally open auxiliary contacts, no normally closed contacts. Coil rated 6 V DC, average pull-in and holding consumption 3.5 W; operating limits 0.85 to 1.1 x Uc for DC supply at temperatures up to 55 °C. Rated operational current AC-15: 4 A at 24 V, 120 V and 240 V, 3 A at 400 V, 2 A at 500 V; DC-13: 2.5 A at 24 V, 0.7 A at 110 V, 0.4 A at 220/240 V. Mechanical durability 10,000,000 cycles. Screw terminals, DIN-rail mounting per IEC 60715, dimensions 52.5 x 46.5 x 57.5 mm, weight 0.175 kg. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1 and UL 60947-4-1.
- KC6-40E-07
The ABB KC6-40E-07 is a 4-pole mini contactor relay with four normally open auxiliary contacts and no normally closed contacts. It has a rated control circuit voltage of 12 V DC and average coil consumption of 3.5 W for both pull-in and holding. Coil operating limits are 0.85 to 1.1 x Uc for DC supply at temperatures up to 55 °C, per IEC 60947-5-1. Screw terminals accept rigid conductors from 1 to 4 mm² and flexible conductors from 1 to 2.5 mm². Dimensions are 52.5 mm wide, 46.5 mm deep, and 57.5 mm high, with a net weight of 0.175 kg. It mounts on TH35-15 or TH35-7.5 DIN rails per IEC 60715 and operates from -25 to +55 °C.