- KC6-40E-07
The ABB KC6-40E-07 is a 4-pole mini contactor relay with four normally open auxiliary contacts and no normally closed contacts. It has a rated control circuit voltage of 12 V DC and average coil consumption of 3.5 W for both pull-in and holding. Coil operating limits are 0.85 to 1.1 x Uc for DC supply at temperatures up to 55 °C, per IEC 60947-5-1. Screw terminals accept rigid conductors from 1 to 4 mm² and flexible conductors from 1 to 2.5 mm². Dimensions are 52.5 mm wide, 46.5 mm deep, and 57.5 mm high, with a net weight of 0.175 kg. It mounts on TH35-15 or TH35-7.5 DIN rails per IEC 60715 and operates from -25 to +55 °C.
- KC6-40E-1.4-81
ABB KC6-40E-1.4-81 interface mini contactor relay with 24 V DC coil, four poles, and four NO auxiliary contacts (no NC contacts). Average pull-in and holding coil consumption is 1.4 W DC. Coil operating limits per IEC 60947-5-1 for DC supply are 0.85 to 1.1 x Uc at ambient temperature up to 55 °C. Rated operational current AC-15 is 4 A at 24, 120, and 240 V, 3 A at 400 V, and 2 A at 500 V; DC-13 is 2.5 A at 24 V, 0.7 A at 110 V, and 0.4 A at 220/240 V. Screw terminals accept rigid 1 to 4 mm² and flexible 1 to 2.5 mm² conductors, tightening torque 0.8 to 1.1 N·m. DIN-rail mounting per IEC 60715. Dimensions 52.5 x 46.5 x 57.5 mm, 0.175 kg. Operating temperature -25 to +55 °C.
- KC6-40E-13
The ABB KC6-40E-13 is a mini contactor relay with four poles and four normally open auxiliary contacts. It uses screw terminals and mounts on DIN rail per IEC 60715, TH35-15 or TH35-7.5. The rated control circuit voltage is 30 V DC, with average pull-in and holding coil consumption of 3.5 W DC. Coil operating limits are 0.85 to 1.1 x Uc for DC supply at ambient temperatures up to 55 °C. Auxiliary circuit rated insulation voltage is 690 V, rated impulse withstand voltage 6 kV, and conventional free-air thermal current 6 A. Dimensions are 52.5 mm wide, 46.5 mm deep, and 57.5 mm high, weighing 0.175 kg. Mechanical durability is 10,000,000 cycles.
- KC6-40E-16
ABB KC6-40E-16 mini contactor relay, 4-pole, with four normally open auxiliary contacts and no normally closed contacts. Rated control circuit voltage is 48 V DC; average pull-in and holding coil consumption is 3.5 W DC. Coil operating limits per IEC 60947-5-1 for DC supply are 0.85 to 1.1 x Uc at ambient temperatures up to 55 °C. Rated insulation voltage is 690 V, rated impulse withstand voltage of the auxiliary circuit is 6 kV, and conventional free-air thermal current is 6 A. Screw terminals accept rigid conductors from 1 to 4 mm² and flexible conductors from 1 to 2.5 mm², with 0.8 to 1.1 N·m tightening torque. Dimensions are 52.5 mm wide, 46.5 mm deep, and 57.5 mm high; net weight 0.175 kg. DIN-rail mounting per IEC 60715. Mechanical durability is 10,000,000 cycles.
- KC6-40E-F-04
ABB KC6-40E-F-04 mini contactor relay with flat-pin connections, 4 poles and 4 NO auxiliary contacts (0 NC). Coil rated control circuit voltage 110 to 125 V DC; average pull-in and holding value DC 3.5 W. Coil operating limits per IEC 60947-5-1 for DC supply are 0.85 to 1.1 x Uc at ambient temperature up to 55 °C. Rated insulation voltage 690 V, rated impulse withstand voltage of the auxiliary circuit 6 kV. Dimensions: 52.5 mm width, 46.5 mm depth, 57.5 mm height; net weight 0.17 kg. DIN-rail or screw mounting on TH35-15 or TH35-7.5 rail per IEC 60715. Mechanical durability 10,000,000 cycles. Ambient operating temperature -25 to +55 °C.
- KC6-40E-F-05
The ABB KC6-40E-F-05 is a 4-pole mini contactor relay with flat-pin connections and four normally open auxiliary contacts. Its rated control circuit voltage is 220 to 240 V DC, with average pull-in and holding coil consumption of 3.5 W DC. Coil operating limits are 0.85 to 1.1 x Uc for DC supply at ambient temperatures up to 55 °C, per IEC 60947-5-1. Rated operational current is 4 A at 24 V, 120 V and 240 V, 3 A at 400 V, and 2 A at 500 V for AC-15; 2.5 A at 24 V, 0.7 A at 110 V, and 0.4 A at 220/240 V for DC-13. Dimensions are 52.5 mm wide, 46.5 mm deep, and 57.5 mm high, weighing 0.17 kg. It mounts on DIN rail per IEC 60715 and operates from -25 to +55 °C.
- KC6-40E-F-1.4-81
ABB mini contactor relay KC6-40E-F-1.4-81, manufacturer ID GJH1213003R8401. Four-pole relay with four NO auxiliary contacts and no NC contacts. Coil rated 24 V DC; average pull-in and holding consumption 1.4 W each. Coil operating limits per IEC 60947-5-1 for DC supply are 0.85 to 1.1 x Uc at up to 55 °C. Auxiliary circuit rated operational voltage 690 V AC and 250 V DC; rated insulation voltage 690 V. AC-15 ratings: 4 A at 24, 120, and 240 V, 3 A at 400 V, 2 A at 500 V. DC-13 ratings: 2.5 A at 24 V, 0.7 A at 110 V, 0.4 A at 220/240 V. Flat-pin terminals, IP20. Dimensions 52.5 x 46.5 x 57.5 mm, 0.17 kg. DIN-rail mounting per IEC 60715. Mechanical durability 10,000,000 cycles.
- KC6-40E-P-01
ABB KC6-40E-P-01 mini contactor relay with 4 poles and 4 NO auxiliary contacts, no NC contacts. Coil rated 24 V DC; average pull-in and holding consumption 3.5 W DC. Coil operating limits for DC supply are 0.85 to 1.1 x Uc at up to 55 °C, per IEC 60947-5-1. Rated operational currents: AC-15 4 A at 24, 120 and 240 V, 3 A at 400 V, 2 A at 500 V; DC-13 2.5 A at 24 V, 0.7 A at 110 V, 0.4 A at 220/240 V. Dimensions 47.5 x 51.5 x 45.5 mm, 0.17 kg. DIN-rail mounting per IEC 60715 (TH35-15, TH35-7.5) or PCB soldering pins. Mechanical durability 10,000,000 cycles. Ambient operation -25 to +55 °C.