- TM-C 630/115-230
The ABB TM-C 630/115-230 is a single-phase control transformer. It has a 630 V·A power supply, a primary voltage of 230-400 V AC, and a secondary voltage of 115-230 V AC at 50/60 Hz. Rated insulation voltage is 3.5 kV, insulation class is F, and power loss is 47 W. The conductor material is copper with a 6 mm² cable cross-section, and the fuse type is aM. Maximum ambient temperature is 40 °C. It measures 154 mm wide, 122 mm high, and 126 mm deep. Standards: EN 61558-2-2, UL506, CSA C22-2-N66. Manufacturer ID: 2CSM207183R0801.
- TM-C 630/12-24
The ABB TM-C 630/12-24 is a one-phase control transformer (ETIM EC002486) with primary voltage 230-400 V AC and secondary voltage 12-24 V AC at 50/60 Hz. Rated power supply is 630 V·A, rated insulation voltage (Ui) is 3.5 kV, insulation class is F, and power loss is 47 W. The conductor material is copper with 6 mm² cable cross-section, and fuse type is aM. Maximum ambient temperature is 40 °C. Dimensions are 154 mm width, 165 mm height, and 126 mm depth. Applicable standards are EN 61558-2-2, UL506, and CSA C22-2-N66. Manufacturer ID 2CSM236813R0801. RoHS information is available separately.
- TM-C-DIN
ABB TM-C-DIN adapter plate, manufacturer ID 2CSM201033R0801, classified under transformer parts. The accessory type is an adapter plate; no accessories are available. Net dimensions are 100 mm width, 20 mm height, and 120 mm depth or length, with a net weight of 100 g. Environmental information is given as see RoHS information. ETIM 8 and ETIM 9 classification is EC002498, accessories or spare parts for low-voltage switch technology. eClass is V11.0: 27371390, and the object classification code is T. WEEE category is 5, small equipment with no external dimension more than 50 cm, business to business. CN8 is 85043190.
- TM-I 1000/115-230 P
The ABB TM-I 1000/115-230 P is a single-phase control and isolating transformer with a power supply of 1000 V·A. It has a primary voltage of 230-400 ±15 V AC and a secondary voltage of 115-230 V AC at a rated frequency of 50/60 Hz. The transformer is built with copper conductors and a cable cross-section of 6 mm². It has an insulation class of F and a rated insulation voltage (Ui) of 4.8 kV. Power loss is 60 W. The maximum ambient temperature is 40 °C. It measures 155 mm in width, 166 mm in height, and 168 mm in depth. Applicable standards are EN 61558-2-2, EN 61558-2-4, UL 506, and CSA C22-2-N66. Fuse type is aM.
- TM-I 160/115-230 P
ABB TM-I 160/115-230 P is a single-phase control transformer, classified under transformer parts. It has a power supply of 160 V·A, a primary voltage of 230-400 ±15 V AC, and a secondary voltage of 115-230 V AC at a rated frequency of 50/60 Hz. Rated insulation voltage (Ui) is 4.8 kV, insulation class is F, power loss is 19 W, and the conductor material is copper with a 6 mm² cable cross-section. The fuse type is aM. It conforms to EN 61558-2-2, EN 61558-2-4, UL 506, and CSA C22-2-N66. Maximum ambient temperature is 40 °C. Net dimensions are 100 mm width, 89 mm height, and 90 mm depth. Manufacturer ID: 2CSM204533R0801.
- TM-I 1600/115-230 P
ABB TM-I 1600/115-230 P transformer, manufacturer ID 2CSM204403R0801, classified as a one-phase control transformer (ETIM 8 and ETIM 9: EC002486). Primary voltage is 230-400 ±15 V AC; secondary voltage is 115-230 V AC at 50/60 Hz. Power supply is 1600 V·A, with power loss of 70 W. Rated insulation voltage (Ui) is 4.8 kV, insulation class F, copper conductor, cable cross-section 6 mm², and aM fuse type. Maximum ambient temperature is 40 °C. Dimensions are 200 mm width, 163 mm height, and 200 mm depth. Standards: EN 61558-2-2, EN 61558-2-4, UL 506, CSA C22-2-N66. RoHS information is available separately.
- TM-I 200/115-230 P
The ABB TM-I 200/115-230 P is a single-phase control and isolating transformer. Its primary voltage is 230-400 ±15 V AC and secondary voltage is 115-230 V AC at 50/60 Hz, with a power supply of 200 V·A and power loss of 21 W. Rated insulation voltage (Ui) is 4.8 kV and insulation class is F. The conductor material is copper with a 6 mm² cable cross-section, and the fuse type is aM. Maximum ambient temperature is 40 °C. Dimensions are 100 mm width, 89 mm height, and 90 mm depth. It is classified under ETIM 8 and ETIM 9 as EC002486, a one-phase control transformer.
- TM-I 2000/115-230 P
ABB TM-I 2000/115-230 P transformer, manufacturer ID 2CSM204383R0801. Primary voltage 230-400 ±15 V AC, secondary voltage 115-230 V AC, rated frequency 50/60 Hz, power supply 2000 V·A. Rated insulation voltage (Ui) 4.8 kV, insulation class F, power loss 85 W. Copper conductor, cable cross-section 6 mm², fuse type aM. Ambient temperature max. 40 °C. Dimensions: 200 mm width, 181 mm height, 230 mm depth. Standards: EN 61558-2-2, EN 61558-2-4, UL 506, CSA C22-2-N66. ETIM 8 and ETIM 9 classification EC002486, one-phase control transformer. Environmental information: see RoHS information.