- BC6-30-01-P-04
The ABB BC6-30-01-P-04 is a 3-pole mini contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 47.5 mm wide, 45.2 mm high, and 47.7 mm deep, and weighs 0.17 kg. The rated control circuit voltage is 110 to 125 V DC, with coil operating limits of 0.85 to 1.1 x Uc at ambient temperatures up to 55 °C per IEC 60947-4-1. Rated operational power AC-3 is 4 kW at 400 V and 500 V three-phase, and 2.2 kW at 230 V three-phase. Rated insulation voltage is 690 V, and rated impulse withstand voltage is 6 kV for main and auxiliary circuits. DIN-rail mounting is supported per IEC 60715. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.
- BC6-30-01-P-05
ABB BC6-30-01-P-05 mini contactor, 3-pole with 3 NO main contacts and 1 NC auxiliary contact. Rated operational voltage: main circuit 690 V AC / 220 V DC, auxiliary circuit 690 V AC / 250 V DC. Rated operational current AC-1: 12 A at 220/240 V and 380/440 V, 6 A at 690 V. Rated operational power AC-3: 2.2 kW at 230 V, 4 kW at 400 V and 500 V, 3 kW at 690 V, three-phase. Control circuit voltage 220 to 240 V DC. Dimensions 47.5 mm width, 45.2 mm height, 47.7 mm depth; net weight 0.17 kg. Mechanical durability 10,000,000 cycles. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L.
- BC6-30-01-P-07
ABB BC6-30-01-P-07 mini contactor, 3-pole, with three main contacts NO and one auxiliary contact NC. Control circuit voltage is 12 V DC; coil operating limits per IEC 60947-4-1 for DC supply are 0.85 to 1.1 x Uc at up to 55 °C. Rated operational voltage is 690 V AC for main and auxiliary circuits, 220 V DC main, 250 V DC auxiliary. Rated operational current AC-1 is 12 A at 220/240 V and 380/440 V, and 6 A at 690 V. Rated operational power AC-3 is 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V. Mechanical durability is 10,000,000 cycles. Dimensions are 47.5 x 45.2 x 47.7 mm; weight 0.17 kg. DIN-rail mounting per IEC 60715.
- BC6-30-01-P-1.4-81
ABB interface mini contactor, display model BC6-30-01-P-1.4-81, manufacturer ID GJL1213009R8011. Three-pole contactor with three normally open main contacts and one normally closed auxiliary contact. Rated control circuit voltage is 24 V DC; coil operating limits per IEC 60947-4-1 for DC supply are 0.85 to 1.1 x Uc at ambient temperatures up to 55 °C. Rated operational power AC-3 is 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V, three-phase. Dimensions are 47.5 mm wide, 45.2 mm high, and 47.7 mm deep, with a net weight of 0.17 kg. DIN-rail mounting is specified for TH35-15 and TH35-7.5 rails per IEC 60715. Ambient operating temperature range is -20 to +55 °C.
- BC6-30-01-P-16
The ABB BC6-30-01-P-16 is a compact 3-pole mini contactor with three normally open main contacts and one normally closed auxiliary contact. Its 48 V DC control coil operates within 0.85 to 1.1 times Uc for DC supply at ambient temperatures up to 55 °C, per IEC 60947-4-1. Rated operational current AC-1 is 12 A at 220/240 V and 380/440 V, and 6 A at 690 V, at both 40 °C and 55 °C. Rated operational power AC-3 is 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V for three-phase loads. Dimensions are 47.5 mm wide, 45.2 mm high, and 47.7 mm deep, weighing 0.17 kg. Mechanical durability is 10,000,000 cycles. Terminal degree of protection is IP20. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.
- BC6-30-01-P-2.4-51
ABB BC6-30-01-P-2.4-51 is a 3-pole interface mini contactor with 3 NO main contacts and 1 NC auxiliary contact. The control circuit is rated 17 to 32 V DC; the main circuit is rated 690 V AC and 220 V DC, with auxiliary circuit ratings of 690 V AC and 250 V DC. Rated operational current AC-1 is 12 A at 220/240 V and 380/440 V, and 6 A at 690 V. Rated operational power AC-3 is 4 kW at 400 V and 500 V, and 3 kW at 690 V. Dimensions are 47.5 mm width, 45.2 mm height, and 47.7 mm depth; net weight is 0.17 kg. Mechanical durability is 10,000,000 cycles. Terminal protection is IP20. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1. No CA6 or CAF6 mountable.
- BC6-30-10-02
The ABB BC6-30-10-02 is a 3-pole mini contactor with three normally open main contacts and one normally open auxiliary contact. It measures 52.5 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.175 kg. Main circuit rated operational voltage is 690 V AC or 220 V DC; auxiliary circuit ratings are 690 V AC and 250 V DC. Rated operational power AC-3 is 2.2 kW at 230 V three-phase, 4 kW at 400 V and 500 V three-phase, and 3 kW at 690 V three-phase. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 690 V for both temperatures. Conventional free-air thermal current is 20 A.
- BC6-30-10-07
ABB BC6-30-10-07 miniature contactor, manufacturer ID GJL1213001R0107. Three-pole (3 NO main contacts, 0 NC) with one NO auxiliary contact and 0 NC auxiliary contacts. Rated control circuit voltage 12 V DC; coil operating limits 0.85 to 1.1 x Uc for DC supply at temperatures up to 55 °C. Main circuit rated operational voltage 690 V AC and 220 V DC; rated insulation voltage 690 V. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 690 V. Rated operational power AC-3 is 4 kW at 400 V and 500 V three-phase. Mechanical durability 10,000,000 cycles. Dimensions 52.5 mm width, 57.5 mm height, 46.7 mm depth; net weight 0.175 kg. Terminal protection IP20; ambient operation -25 to +55 °C.