- BC6-30-10-07
ABB BC6-30-10-07 miniature contactor, manufacturer ID GJL1213001R0107. Three-pole (3 NO main contacts, 0 NC) with one NO auxiliary contact and 0 NC auxiliary contacts. Rated control circuit voltage 12 V DC; coil operating limits 0.85 to 1.1 x Uc for DC supply at temperatures up to 55 °C. Main circuit rated operational voltage 690 V AC and 220 V DC; rated insulation voltage 690 V. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 690 V. Rated operational power AC-3 is 4 kW at 400 V and 500 V three-phase. Mechanical durability 10,000,000 cycles. Dimensions 52.5 mm width, 57.5 mm height, 46.7 mm depth; net weight 0.175 kg. Terminal protection IP20; ambient operation -25 to +55 °C.
- BC6-30-10-1.4-81
The ABB BC6-30-10-1.4-81 is an interface mini contactor with three normally open main contacts and one normally open auxiliary contact. Its 24 V DC control coil operates within 0.85 to 1.1 x Uc at ambient temperatures up to 55 °C, per IEC 60947-4-1. Main circuit ratings include 690 V AC, 20 A AC-1 at 40 °C, and AC-3 motor power of 2.2 kW at 230 V and 4 kW at 400 V. Dimensions are 52.5 mm wide, 57.5 mm high, and 46.7 mm deep, weighing 0.175 kg. Mechanical durability is 10,000,000 cycles. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1. CA6 or CAF6 accessories cannot be mounted.
- BC6-30-10-13
The ABB BC6-30-10-13 is a mini contactor with three normally open main contacts and one normally open auxiliary contact. The control circuit is rated 30 V DC, with coil operating limits of 0.85 to 1.1 x Uc according to IEC 60947-4-1 for DC supply at ambient temperatures up to 55 °C. Main circuit rated operational voltage is 690 V AC; rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V. Rated operational power AC-3 is 4 kW at 400 V and 500 V three-phase. Mechanical durability is 10,000,000 cycles. Dimensions are 52.5 mm width, 57.5 mm height, and 46.7 mm depth, with a net weight of 0.175 kg.
- BC6-30-10-2.4-51
The ABB BC6-30-10-2.4-51 is a 3-pole interface mini contactor with three normally open main contacts and one normally open auxiliary contact. The control circuit is rated 17 to 32 V DC, and the coil operating limits follow IEC 60947-4-1 for DC supply at ambient temperatures up to 55 °C. Main and auxiliary circuits are rated 690 V AC and 220 V DC, with a rated impulse withstand voltage of 6 kV. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V; AC-3 rated power is 4 kW at 400 V and 500 V. Dimensions are 52.5 mm wide, 57.5 mm high, and 46.7 mm deep, weighing 0.175 kg. Mechanical durability is 10,000,000 cycles. Terminals are IP20. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.
- BC6-30-10-2.4-54
The ABB BC6-30-10-2.4-54 is a 3-pole interface mini contactor with three normally open main contacts and one normally open auxiliary contact. It measures 52.5 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.175 kg. The control circuit is rated 36 to 65 V DC. Main circuit ratings include 690 V AC and 220 V DC, with a rated impulse withstand voltage of 6 kV and rated insulation voltage of 690 V. Rated operational power AC-3 is 4 kW at 400 V three-phase. Mechanical durability is 10,000,000 cycles. Terminals accept rigid conductors from 1 to 4 mm² and are IP20 rated. DIN rail mounting is per IEC 60715. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, and IEC/EN 60947-5-1.
- BC6-30-10-F-01
The ABB BC6-30-10-F-01 is a 3-pole mini contactor with three normally open main contacts and one normally open auxiliary contact. Its 24 V DC control coil operates within 0.85 to 1.1 times the control voltage at ambient temperatures up to 55 °C. Rated operational voltage is 690 V AC for the main and auxiliary circuits, and rated insulation voltage is 690 V. AC-1 rated operational current is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 690 V. AC-3 rated operational power is 4 kW at 400 V and 500 V. Mechanical durability is 10,000,000 cycles. Dimensions are 52.5 mm wide, 57.5 mm high, and 46.7 mm deep, weighing 0.17 kg.
- BC6-30-10-F-07
The ABB BC6-30-10-F-07 is a 3-pole mini contactor with three normally open main contacts and one normally open auxiliary contact. It measures 52.5 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.17 kg. The control circuit is rated 12 V DC, with coil operating limits of 0.85 to 1.1 x Uc according to IEC 60947-4-1 for DC supply at ambient temperatures up to 55 °C. Main circuit ratings include 690 V AC and 220 V DC, with 50 Hz, 60 Hz, and DC main circuit frequencies. Rated operational current AC-1 is 20 A at 40 °C for 220/240 V and 380/440 V, and 6 A at 690 V. Rated operational power AC-3 is 4 kW at 400 V and 500 V. Terminal protection is IP20.
- BC6-30-10-F-1.4-81
ABB mini contactor BC6-30-10-F-1.4-81, an interface mini contactor with three poles, three main contacts NO and one auxiliary contact NO. The control circuit is 24 V DC; coil operating limits are 0.85 to 1.1 x Uc at up to 55 °C per IEC 60947-4-1. Main circuit rated operational voltage is 690 V AC and 220 V DC, with rated insulation voltage 690 V and impulse withstand voltage 6 kV. AC-3 rated operational power is 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V three phase. Dimensions are 52.5 mm wide, 57.5 mm high, 46.7 mm deep; weight 0.17 kg. Mechanical durability is 10000000 cycles. Mounting is on TH35-15 or TH35-7.5 DIN rail per IEC 60715.