Q1Can you supply the ABB PSR16-600-11?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the ABB PSR16-600-11 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
PSR16-600-11
Material Number
1SFA896107R1100
Manufacturer
ABB
Product ID
76618

Get a Free Quote

Request pricing and availability for PSR16-600-11.

More parts to source? Send your whole list in one enquiry

Key specifications

Product Net Weight
0.4 kg
Rated Operational Voltage
208 ... 600 V AC
Rated Control Supply Voltage (Us)
24 V AC/DC
Rated Frequency (f)
50/60 Hz Main Circuit 50 / 60 Hz
Rated Operational Power - In-Line Connection (Pe)
(230 V) 4 kW (400 V) 7.5 kW (500 V) 7.5 kW
Rated Operational Current - In-Line Connection (Ie)
16 A
See all specifications

Product Highlights

  1. Compact Dimensions: 45 mm depth, 114 mm width, 140 mm height, and 0.4 kg net weight
  2. Electrical Ratings: 208 to 600 V AC operational voltage, 16 A rated in-line current, and 50/60 Hz frequency
  3. Motor Power Ratings: 4 kW at 230 V, 7.5 kW at 400 V and 500 V, and UL/CSA ratings of 3 Hp at 200 to 208 V, 5 Hp at 220 to 240 V, and 10 Hp at 440 to 480 V and 550 to 600 V
  4. Starting Performance: 4x rated current for 6 seconds, ramp time 0 to 20 seconds or 1 to 10 seconds, initial voltage 40 to 70 percent, and step-down voltage 100 to 60 percent
  5. Control and Protection: 24 V AC/DC control supply, run signal relay, screw terminals, and recommended MS132 10 to 16 A overload protection with no integrated electronic overload
  6. Operating Conditions: -25 to +60 °C ambient operation, -40 to +70 °C storage, and IP20 main terminal protection
PSR16-600-11

Product Information

Technical Specifications

Specifications for PSR16-600-11

ParameterValue
Product Net Width114 mm
Product Net Height140 mm
Product Net Depth / Length45 mm
Product Net Weight0.4 kg
Rated Operational Voltage208 ... 600 V AC
Rated Control Supply Voltage (Us)24 V AC/DC
Rated Control Circuit Voltage (Uc)24 V DC
Rated Frequency (f)50/60 Hz Main Circuit 50 / 60 Hz
Rated Operational Power - In-Line Connection (Pe)(230 V) 4 kW (400 V) 7.5 kW (500 V) 7.5 kW
Rated Operational Current - In-Line Connection (Ie)16 A
Service Factor Percentage100 %
Overload ProtectionRecommended MS132 10.00 ... 16.00
Integrated Electronic OverloadNo
Adjustable Rated Motor Current IeNo
Starting Capacity at Maximum Rated Current Ie4xIe for 6s
Ramp Time0 ... 20 second [unit of time] 1 ... 10 second [unit of time]
Initial Voltage During Start40 ... 70 %
Step Down Voltage Special Ramp100 ... 60 %
Current Limit FunctionNo
Switch for Inside Delta ConnectionNo
Run Signal RelayYes
By-pass Signal RelayNo
Fault Signal RelayNo
Overload Signal RelayNo
Signal Indication Completed Start Ramp (LED)Green
ParameterValue
Signal Indication Ready to Start/Standby ON (LED)Green
Signal Indication Running R (LED)Green
Signal Indication Ramping Up/Down (LED)Green
Number of Starts Per Hour at 3.5*Ie for 7 sec. 50% ON Time 50% OFF Time10
CommunicationFiledBusPlug(Optional)
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Terminal TypeScrew Terminals
Connecting Capacity Main CircuitRigid 1/2 x 0.75 ... 2.5 mm²
Connecting Capacity Control Circuit1 x 0.75 ... 2.5 2 x 0.75 ... 2.5 mm² Rigid 1/2 x 0.75 ... 2.5 mm²
Connecting Capacity Supply CircuitRigid 1/2 x 0.75 ... 2.5 mm²
Tightening TorqueControl Circuit 1 N·m Main Circuit 1 N·m Supply Circuit 1 N·m
Product Main TypePSR16
FunctionSoft start with voltage ramp Soft stop with voltage ramp
Horsepower Rating UL/CSA(200 ... 208 V AC) Three Phase 3 Hp (220 ... 240 V AC) Three Phase 5 Hp (440 ... 480 V AC) Three Phase 10 Hp (550 ... 600 V AC) Three Phase 10 Hp
Maximum Operating Voltage UL/CSAMain Circuit 600 V
Tightening Torque UL/CSAControl Circuit 8.9 in·lb Main Circuit 8.9 Supply Circuit 8.9 in·lb
Ambient Air TemperatureOperation -25 ... +60 °C Storage -40 ... +70 °C
Object Classification CodeQ
ETIM 7EC000640 - Soft starter
ETIM 8EC000640 - Soft starter
ETIM 9EC000640 - Soft starter
eClassV11.0 : 27370907
UNSPSC39121521
IDEA Granular Category Code (IGCC)4740 >> Soft starter
Manufacturer ID1SFA896107R1100

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp