- PSR45-MS450
ABB connection kit, product main type PSR45-MS450, manufacturer ID 1SFA896213R1001. It is classified as a spare part/accessory for low-voltage switch technology (ETIM 8 and ETIM 9: EC002498; eClass V11.0: 27371392; UNSPSC: 39121400; object classification code Q). Dimensions are 54 mm net width, 50 mm net height, and 25 mm net depth/length, with a net weight of 0.03 kg. The supplied data does not state a rated voltage, current, or short-circuit rating, nor any standard or certification. No compatibility with specific soft starter or manual motor starter series is confirmed by the authoritative parameters.
- PSR85-600-11
ABB PSR85-600-11 softstarter, manufacturer ID 1SFA896114R1100, rated 85 A at 208 to 600 V AC, 50/60 Hz. Rated operational power in in-line connection is 22 kW at 230 V, 45 kW at 400 V, and 55 kW at 500 V. Control supply voltage is 24 V AC/DC; control circuit voltage is 24 V DC. Starting capacity is 4xIe for 6 s, with ramp time 0 to 20 s and 1 to 10 s, initial voltage 40 to 70 percent, and step-down voltage 100 to 60 percent. Service factor is 100 percent. Recommended overload protection is MS495 70 to 90. Integrated electronic overload, adjustable rated motor current, current limit function, and inside-delta switch are not included. Dimensions are 180 mm wide, 220 mm high, 70 mm deep; net weight 2.1 kg.
- PSR85-600-70
ABB PSR85-600-70 softstarter, manufacturer ID 1SFA896114R7000. Rated operational voltage 208 to 600 V AC, rated operational current 85 A in-line connection, service factor 100%. Rated operational power in-line: 22 kW at 230 V, 45 kW at 400 V, 55 kW at 500 V. Rated control supply voltage 100 to 240 V AC; rated control circuit voltage 24 V DC; rated frequency 50/60 Hz. Starting capacity 4xIe for 6s. Ramp time 0 to 20 s and 1 to 10 s. Initial voltage during start 40 to 70%; step-down voltage special ramp 100 to 60%. No integrated electronic overload, no adjustable rated motor current, no current limit function, no inside-delta switch. Recommended overload protection MS495 70 to 90. Dimensions 180 x 220 x 70 mm; net weight 2.1 kg.
- PSRC12-600-70
The ABB PSRC12-600-70 soft starter (manufacturer ID 1SFA896206R7000) operates at 208 to 600 V AC with a rated operational current of 12 A and a service factor of 100%. Rated operational power is 3 kW at 230 V, 5.5 kW at 400 V, and 5.5 kW at 500 V for in-line connection. The main circuit rated frequency is 50/60 Hz. Control supply voltage is 100 to 240 V AC; control circuit voltage is 24 V DC. Starting capacity is 4xIe for 6s. Ramp time, initial voltage during start, and step-down voltage are fixed settings. Current limit and inside-delta connection switches are not provided. A run signal relay is included. Recommended overload protection is MS132 10.00 to 16.00. Dimensions are 114 mm width, 140 mm height, and 45 mm depth, with 0.4 kg net weight.
- PSRC25-600-70
ABB softstarter, product main type PSRC25, display model PSRC25-600-70, manufacturer ID 1SFA896208R7000. Rated operational current in-line connection is 25 A at a rated operational voltage of 208 to 600 V AC, 50/60 Hz. Rated operational power in-line connection is 5.5 kW at 230 V, 11 kW at 400 V, and 15 kW at 500 V. Rated control supply voltage is 100 to 240 V AC; rated control circuit voltage is 24 V DC. Starting capacity is 4xIe for 6 s, with 10 starts per hour at 3.5xIe for 7 s, 50% on time and 50% off time. Dimensions are 160 mm height, 128 mm width, and 45 mm depth; net weight is 0.6 kg. Main terminals are IP20 according to IEC 60529, IEC 60947-1, and EN 60529.
- PSRC3-600-70
ABB softstarter, product main type PSRC3, display model PSRC3-600-70, manufacturer ID 1SFA896203R7000. Rated operational voltage 208 ... 600 V AC, rated frequency 50/60 Hz main circuit. Rated operational current in-line connection 3.9 A; rated operational power in-line connection 0.75 kW at 230 V, 1.5 kW at 400 V, 2.2 kW at 500 V. Rated control supply voltage 100 ... 240 V AC; rated control circuit voltage 24 V DC. Function: soft start with voltage ramp and soft stop with voltage ramp; ramp time, initial voltage, and step-down voltage are fixed settings. No current limit function, no integrated electronic overload, no inside-delta switch. Starting capacity 4xIe for 6s. Screw terminals, main terminals IP20 per IEC 60529, IEC 60947-1, EN 60529. Dimensions 114 mm x 140 mm x 45 mm, 0.4 kg.
- PSRC30-600-70
ABB PSRC30-600-70 soft starter, manufacturer ID 1SFA896209R7000, product main type PSRC30. Rated operational voltage 208 to 600 V AC, rated control supply voltage 100 to 240 V AC, rated control circuit voltage 24 V DC, rated frequency 50/60 Hz main circuit. Rated operational current in-line connection 30 A; rated operational power in-line connection 7.5 kW at 230 V, 15 kW at 400 V, 18.5 kW at 500 V. Starting capacity 4xIe for 6s. Ramp time, initial voltage during start, and step-down voltage special ramp are fixed settings. No current limit function and no integrated electronic overload; recommended overload protection MS132 25 to 32. Function: soft start with voltage ramp and soft stop with voltage ramp. Dimensions 128 mm width, 160 mm height, 45 mm depth, 0.6 kg.
- PSRM1515
ABB PSRM1515 is an industrial catalog item. Key specifications include Sub-Function 3: Fastening profile, Suitable For: Modular boards - System pro E Power, Suitable for Product Class: Main Distribution Boards, and Product Type: 5P5P20P2090. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.