- OS400D22F
The ABB OS400D22F is a four-pole fuse protector with a rated current of 400 A in the main circuit and a rated operational voltage of 690 V AC. It is a front-operated, base-mounting device with DIN fuse system support for NH0, NH1, and NH2 fuse sizes. Terminal type is lug terminals, 25 mm wide, with a tightening torque of 30 to 44 N·m. Rated insulation voltage is 1000 V and rated impulse withstand voltage is 12 kV. The rated conditional short-circuit current is 80 kA at 690 V, and the rated short-time withstand current is 14 kA rms for 1 s. It conforms to IEC 60947-3. Handle and shaft are not included. Net dimensions are 319 mm width, 230 mm height, and 193 mm depth; net weight is 7.99 kg.
- OS400D22FP
ABB OS400D22FP fuse protector, four-pole, front-operated, base mounting. Rated current 400 A; rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV. Conventional free-air thermal current 400 A at 40 °C; conventional thermal current 400 A fully enclosed. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 14 kA rms for 1 s. DIN fuse system, fuse sizes NH0, NH1, NH2. Fourth pole switched-fusible. Lug terminals, 25 mm width, tightening torque 30 to 44 N·m. Pistol handle and shaft included. Pollution degree 3. Power loss 30 W per pole at rated operating conditions. Dimensions 318 mm width, 230 mm height, 193 mm depth; net weight 8.41 kg. Standard IEC 60947-3.
- OS400D22LR
ABB OS400D22LR fuse switch disconnector, four-pole, front-operated, base mounting. Rated current 400 A; rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV. Conventional free-air thermal current 400 A at 40 °C; conventional thermal current 630 A fully enclosed. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 14 kA rms for 1 s. Accepts NH0, NH1 and NH2 DIN fuses. Lug terminals, 25 mm wide, tightening torque 30 to 44 N·m. Power loss 40 W per pole at rated operating conditions. Pollution degree 3. Dimensions 407 x 200 x 255 mm; weight 12.8 kg. Complies with IEC 60947-3. Handle and shaft not included.
- OS400D22LRP
The ABB OS400D22LRP is a four-pole fuse switch disconnector for base mounting, front operated, with line terminals left in and right out. It accepts DIN fuse sizes NH0, NH1 and NH2, and the fourth pole is switched-fusible. Rated current is 400 A; rated operational voltage is 690 V AC. Conventional free-air thermal current is 400 A at 40 °C, and conventional thermal current fully enclosed is 400 A. Rated conditional short-circuit current is 80 kA at 690 V, rated impulse withstand voltage is 12 kV, and rated insulation voltage is 1000 V. It conforms to IEC 60947-3. Net dimensions are 463 mm wide, 194 mm high and 201 mm deep; net weight is 12.42 kg. A pistol handle and shaft are included.
- OS400D22N1P
The ABB OS400D22N1P is a four-pole front-operated fuse switch disconnector for DIN fuse systems, accepting NH0, NH1, and NH2 fuse sizes. It is rated 400 A at 690 V AC and complies with IEC 60947-3. The fourth pole is switched with a solid link and positioned on the left side. A pistol handle and shaft are included. Line terminals can be configured top-in/bottom-out or bottom-in/top-out. The unit has a rated insulation voltage of 1000 V, a rated impulse withstand voltage of 12 kV, and a rated conditional short-circuit current of 80 kA at 690 V. Power loss is 30 W per pole at rated operating conditions. Dimensions are 318 mm wide, 230 mm high, and 193 mm deep, with a net weight of 8.41 kg.
- OS400D30-3
The ABB OS400D30-3 is a front-operated fuse switch disconnector for DIN fuse systems. It has three poles, base mounting, and lug terminals. It accepts NH0, NH1, and NH2 fuse sizes. The main circuit is rated 690 V AC, and power loss is 30 W per pole at rated operating conditions. Terminal tightening torque is 30 to 44 N·m. Dimensions are 270 mm width, 240 mm height, and 206 mm depth; net weight is 5.865 kg. The device is classified under IEC 60947-3. Manufacturer ID: 1SCA022780R3870. ETIM 8 and ETIM 9 classify it as EC001040 fuse switch disconnector.
- OS400D30N3
ABB OS400D30N3 fuse switch disconnector, 3-pole, front-operated, base mounting. Rated current 400 A; rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV. Conventional free-air thermal current 400 A at 40 °C; enclosed thermal current 400 A. Rated conditional short-circuit current 80 kA at 690 V; short-time withstand current 14 kA rms for 1 s. Power loss 30 W per pole at rated operating conditions. Accepts NH0, NH1, and NH2 fuses in a DIN fuse system. Fourth pole is a detachable neutral link integrated into the mechanism. Lug terminals, 25 mm wide, tightened to 30 to 44 N·m. Pollution degree 3. Complies with IEC 60947-3. Handle and shaft not included. Dimensions 255 mm wide, 230 mm high, 193 mm deep; 6.78 kg.
- OS400D30P
The ABB OS400D30P is a front-operated, 3-pole fuse switch disconnector for base mounting, with a pistol handle and shaft included. It accepts NH0, NH1, and NH2 fuses in a DIN fuse system. The main circuit is rated 400 A and 690 V AC, with a rated insulation voltage of 1000 V and a rated impulse withstand voltage of 12 kV. Conventional free-air thermal current is 400 A at 40 °C; enclosed thermal current is 400 A. Rated conditional short-circuit current is 80 kA at 690 V, and rated short-time withstand current is 14 kA rms for 1 s. Line terminals can be top-in/bottom-out or bottom-in/top-out. Dimensions are 255 mm wide, 230 mm high, and 193 mm deep; net weight is 6.72 kg. Power loss is 30 W per pole at rated operating conditions. It conforms to IEC 60947-3.