ABB OS400D31N2 fuse protector, category fuse switch disconnector. Four-pole, front-operated, base-mounting unit with switched fourth pole on the right side including solid link. Rated current 400 A; rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV. Conventional free-air thermal current 400 A at 40 °C; conventional thermal current 400 A fully enclosed. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 14 kA rms for 1 s. Power loss 30 W per pole at rated operating conditions. Accepts NH0, NH1 and NH2 fuses in DIN fuse system. Lug terminals, 25 mm terminal width, tightening torque 30 to 44 N·m. Pollution degree 3. Dimensions 193 mm wide, 319 mm high, 230 mm deep; net weight 8.0 kg. Conforms to IEC 60947-3. Handle and shaft not included.
- OS400D40F
ABB OS400D40F fuse switch disconnector, 4-pole, front-operated, base mounting. Rated current 400 A; rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV. Conventional free-air thermal current 400 A at 40 °C; conventional thermal current fully enclosed 400 A. Rated conditional short-circuit current 80 kA at 690 V. Rated short-time withstand current 14 kA rms for 1 s. Power loss 30 W per pole at rated operating conditions. DIN fuse system, fuse sizes NH0, NH1, NH2. Fourth pole switched-fusible. Lug terminals, 25 mm terminal width, tightening torque 30 to 44 N·m. Standards: IEC 60947-3. Pollution degree 3. Dimensions 319 mm width, 230 mm height, 193 mm depth; net weight 7.99 kg. Handle and shaft not included.
- OS400D40FP
The ABB OS400D40FP is a four-pole fuse switch disconnector with a rated current of 400 A in the main circuit and a rated operational voltage of 690 V AC. It accepts NH0, NH1, and NH2 fuses in a DIN fuse system and is front operated via an included pistol handle and shaft. The fourth pole is a switched, fusible pole. Line terminals can be configured top in/bottom out or bottom in/top out. Rated insulation voltage is 1000 V, rated impulse withstand voltage is 12 kV, and rated conditional short-circuit current is 80 kA at 690 V. It complies with IEC 60947-3. Dimensions are 319 mm wide, 230 mm high, and 193 mm deep, with a net weight of 8.41 kg.
- OS400D40N1
ABB OS400D40N1 fuse protector, a four-pole front-operated fuse switch disconnector for base mounting. Main circuit rated 690 V AC, 400 A, with rated insulation voltage 1000 V and rated impulse withstand voltage 12 kV. Conventional free-air thermal current 400 A at 40 °C; enclosed thermal current 400 A. Rated conditional short-circuit current 80 kA at 690 V; short-time withstand current 14 kA rms for 1 s. Fuse system DIN, fuse sizes NH0, NH1 and NH2. Lug terminals, 25 mm terminal width, tightening torque 30 to 44 N·m. Power loss 30 W per pole at rated operating conditions. Pollution degree 3. Standards: IEC 60947-3. Handle and shaft not included. Net dimensions 319 mm width, 230 mm height, 193 mm depth; net weight 7.99 kg.
- OS400D40N1P
The ABB OS400D40N1P is a four-pole fuse switch disconnector for base mounting, front operated via an included pistol handle and shaft. It accepts NH0, NH1, and NH2 fuses in a DIN fuse system. Rated current is 400 A in the main circuit, with conventional free-air thermal current 400 A at 40 °C and fully enclosed thermal current 400 A. Rated operational voltage is 690 V AC; rated insulation voltage is 1000 V and rated impulse withstand voltage is 12 kV. Rated conditional short-circuit current is 80 kA at 690 V, and rated short-time withstand current is 14 kA rms for 1 s. Power loss is 30 W per pole at rated operating conditions. Dimensions are 319 mm wide, 230 mm high, and 193 mm deep; net weight is 8.41 kg. Standards: IEC 60947-3.
- OS400DS03
ABB OS400DS03 is a 3-pole fuse protector for base mounting, side operated, with fuse sizes NH0, NH1, and NH2 in the DIN fuse system. The main circuit rated current is 400 A. Conventional free-air thermal current Ith is 400 A at 40 °C; conventional thermal current Ithe is 400 A fully enclosed. Rated insulation voltage Ui is 1000 V, rated impulse withstand voltage Uimp is 12 kV, and rated conditional short-circuit current Inc is 80 kA at 690 V. Power loss is 30 W per pole at rated operating conditions. Line terminals may be top in - bottom out or bottom in - top out. Pollution degree 3. Dimensions are 288 mm width, 230 mm height, and 193 mm depth; net weight is 6.675 kg. Handle and shaft are not included. Manufacturer ID: 1SCA022860R3480.
- OS400DS03K
ABB OS400DS03K fuse protector, three-pole, side-operated with direct-mounted handle included. Rated current 400 A in the main circuit; conventional free-air thermal current 400 A at 40 °C and conventional thermal current 400 A fully enclosed. Rated operational voltage 690 V AC, rated insulation voltage 1000 V, rated impulse withstand voltage 12 kV. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 14 kA rms for 1 s. Accepts NH0, NH1 and NH2 DIN fuse sizes. Lug terminals, 25 mm wide, tightening torque 30 to 44 N·m. Power loss 30 W per pole at rated operating conditions. Dimensions 288 mm wide, 230 mm high, 193 mm deep; net weight 6.82 kg. Base mounting, pollution degree 3, conforms to IEC 60947-3.
- OS400DS04F
The ABB OS400DS04F is a 4-pole fuse switch disconnector with side operation and base mounting. It accepts NH0, NH1, and NH2 DIN fuse links, with the fourth pole configured as a switched-fusible pole. The main circuit is rated 400 A at 690 V AC, with a rated insulation voltage of 1000 V and a rated impulse withstand voltage of 12 kV. Conventional free-air thermal current is 400 A at 40 °C; enclosed thermal current is 400 A. Rated conditional short-circuit current is 80 kA at 690 V, and short-time withstand current is 14 kA rms for 1 s. Power loss is 30 W per pole at rated operating conditions. Lug terminals are 25 mm wide, tightened to 30 to 44 N·m. Pollution degree 3. IEC 60947-3. Handle and shaft are not included.