- OS400D40F
ABB OS400D40F fuse switch disconnector, 4-pole, front-operated, base mounting. Rated current 400 A; rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV. Conventional free-air thermal current 400 A at 40 °C; conventional thermal current fully enclosed 400 A. Rated conditional short-circuit current 80 kA at 690 V. Rated short-time withstand current 14 kA rms for 1 s. Power loss 30 W per pole at rated operating conditions. DIN fuse system, fuse sizes NH0, NH1, NH2. Fourth pole switched-fusible. Lug terminals, 25 mm terminal width, tightening torque 30 to 44 N·m. Standards: IEC 60947-3. Pollution degree 3. Dimensions 319 mm width, 230 mm height, 193 mm depth; net weight 7.99 kg. Handle and shaft not included.
- OS400D40FP
The ABB OS400D40FP is a four-pole fuse switch disconnector with a rated current of 400 A in the main circuit and a rated operational voltage of 690 V AC. It accepts NH0, NH1, and NH2 fuses in a DIN fuse system and is front operated via an included pistol handle and shaft. The fourth pole is a switched, fusible pole. Line terminals can be configured top in/bottom out or bottom in/top out. Rated insulation voltage is 1000 V, rated impulse withstand voltage is 12 kV, and rated conditional short-circuit current is 80 kA at 690 V. It complies with IEC 60947-3. Dimensions are 319 mm wide, 230 mm high, and 193 mm deep, with a net weight of 8.41 kg.
- OS400D40N1
ABB OS400D40N1 fuse protector, a four-pole front-operated fuse switch disconnector for base mounting. Main circuit rated 690 V AC, 400 A, with rated insulation voltage 1000 V and rated impulse withstand voltage 12 kV. Conventional free-air thermal current 400 A at 40 °C; enclosed thermal current 400 A. Rated conditional short-circuit current 80 kA at 690 V; short-time withstand current 14 kA rms for 1 s. Fuse system DIN, fuse sizes NH0, NH1 and NH2. Lug terminals, 25 mm terminal width, tightening torque 30 to 44 N·m. Power loss 30 W per pole at rated operating conditions. Pollution degree 3. Standards: IEC 60947-3. Handle and shaft not included. Net dimensions 319 mm width, 230 mm height, 193 mm depth; net weight 7.99 kg.
- OS400D40N1P
The ABB OS400D40N1P is a four-pole fuse switch disconnector for base mounting, front operated via an included pistol handle and shaft. It accepts NH0, NH1, and NH2 fuses in a DIN fuse system. Rated current is 400 A in the main circuit, with conventional free-air thermal current 400 A at 40 °C and fully enclosed thermal current 400 A. Rated operational voltage is 690 V AC; rated insulation voltage is 1000 V and rated impulse withstand voltage is 12 kV. Rated conditional short-circuit current is 80 kA at 690 V, and rated short-time withstand current is 14 kA rms for 1 s. Power loss is 30 W per pole at rated operating conditions. Dimensions are 319 mm wide, 230 mm high, and 193 mm deep; net weight is 8.41 kg. Standards: IEC 60947-3.
- OS400DS03
ABB OS400DS03 is a 3-pole fuse protector for base mounting, side operated, with fuse sizes NH0, NH1, and NH2 in the DIN fuse system. The main circuit rated current is 400 A. Conventional free-air thermal current Ith is 400 A at 40 °C; conventional thermal current Ithe is 400 A fully enclosed. Rated insulation voltage Ui is 1000 V, rated impulse withstand voltage Uimp is 12 kV, and rated conditional short-circuit current Inc is 80 kA at 690 V. Power loss is 30 W per pole at rated operating conditions. Line terminals may be top in - bottom out or bottom in - top out. Pollution degree 3. Dimensions are 288 mm width, 230 mm height, and 193 mm depth; net weight is 6.675 kg. Handle and shaft are not included. Manufacturer ID: 1SCA022860R3480.
- OS400DS03K
ABB OS400DS03K fuse protector, three-pole, side-operated with direct-mounted handle included. Rated current 400 A in the main circuit; conventional free-air thermal current 400 A at 40 °C and conventional thermal current 400 A fully enclosed. Rated operational voltage 690 V AC, rated insulation voltage 1000 V, rated impulse withstand voltage 12 kV. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 14 kA rms for 1 s. Accepts NH0, NH1 and NH2 DIN fuse sizes. Lug terminals, 25 mm wide, tightening torque 30 to 44 N·m. Power loss 30 W per pole at rated operating conditions. Dimensions 288 mm wide, 230 mm high, 193 mm deep; net weight 6.82 kg. Base mounting, pollution degree 3, conforms to IEC 60947-3.
- OS400DS04F
The ABB OS400DS04F is a 4-pole fuse switch disconnector with side operation and base mounting. It accepts NH0, NH1, and NH2 DIN fuse links, with the fourth pole configured as a switched-fusible pole. The main circuit is rated 400 A at 690 V AC, with a rated insulation voltage of 1000 V and a rated impulse withstand voltage of 12 kV. Conventional free-air thermal current is 400 A at 40 °C; enclosed thermal current is 400 A. Rated conditional short-circuit current is 80 kA at 690 V, and short-time withstand current is 14 kA rms for 1 s. Power loss is 30 W per pole at rated operating conditions. Lug terminals are 25 mm wide, tightened to 30 to 44 N·m. Pollution degree 3. IEC 60947-3. Handle and shaft are not included.
- OS400DS04FK
ABB OS400DS04FK fuse switch disconnector, four-pole, side-operated with direct-mounted handle included. Rated current 400 A; rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV. Conventional free-air thermal current 400 A at 40 °C; fully enclosed thermal current 400 A. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 14 kA rms for 1 s. Accepts DIN fuse sizes NH0, NH1, NH2. Fourth pole is switched-fusible. Lug terminals, 25 mm wide, tightening torque 30 to 44 N·m. Power loss 30 W per pole at rated operating conditions. Pollution degree 3. Dimensions 352 x 230 x 193 mm; net weight 8.595 kg. Standards: IEC 60947-3.