- OS400D13N2P
The ABB OS400D13N2P is a 4-pole fuse switch disconnector for DIN fuse systems, accepting NH0, NH1, and NH2 fuse sizes. It is rated 400 A at 690 V AC, with a rated insulation voltage of 1000 V and a rated impulse withstand voltage of 12 kV. Conventional free-air thermal current is 400 A at 40 °C; enclosed thermal current is 400 A. Rated conditional short-circuit current is 80 kA at 690 V, and short-time withstand current is 14 kA rms for 1 s. The fourth pole is switched with a solid link on the right side. It uses base mounting, front operation, a pistol handle and shaft, and 25 mm lug terminals tightened to 30 to 44 N·m. Standards: IEC 60947-3.
- OS400D21
The ABB OS400D21 is a three-pole fuse protector for base mounting with front operation. It accepts DIN fuse systems in sizes NH0, NH1, and NH2, and uses lug terminals with a tightening torque of 30 to 44 N·m. The main circuit is rated at 690 V AC. Power loss is 30 W per pole at rated operating conditions. Dimensions are 193 mm wide, 255 mm high, and 230 mm deep; net weight is 6.3 kg. The product is classified under IEC 60947-3. Manufacturer ID 1SCA150267R1001. ETIM 8 and ETIM 9 classification is EC001040, fuse switch disconnector.
- OS400D21LR
ABB OS400D21LR fuse protector, identified by manufacturer ID 1SCA022853R2100. Three-pole, front-operated fuse switch disconnector for base mounting with left line and right load terminals. Rated current 400 A; rated operational voltage 690 V AC. Conventional free-air thermal current 400 A at 40 °C; conventional thermal current 630 A fully enclosed. Rated insulation voltage 1000 V, rated impulse withstand voltage 12 kV, rated conditional short-circuit current 80 kA at 690 V, and short-time withstand current 14 kA rms for 1 s. Accepts NH0, NH1, and NH2 DIN fuses. Power loss 40 W per pole at rated operating conditions. Lug terminals, 25 mm wide, tightened to 30 to 44 N·m. Pollution degree 3. Dimensions 344 x 150 x 255 mm; 9.6 kg. Conforms to IEC 60947-3. Handle and shaft not included.
- OS400D21LRP
ABB OS400D21LRP fuse switch disconnector, 3-pole, front-operated, base mounting, with pistol handle and shaft included. Rated current 400 A; rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV. Conventional free-air thermal current 400 A at 40 °C; conventional thermal current 400 A fully enclosed. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 14 kA rms for 1 s. Accepts NH0, NH1 and NH2 DIN fuse sizes. Lug terminals, 25 mm terminal width, tightening torque 30 to 44 N·m. Power loss 40 W per pole at rated operating conditions. Pollution degree 3. Standards: IEC 60947-3. Dimensions 400 mm width, 194 mm height, 201 mm depth; weight 9.4 kg.
- OS400D21P
The ABB OS400D21P is a three-pole fuse protector for base mounting with front operation. It accepts DIN fuse sizes NH0, NH1, and NH2, and uses lug terminals with a tightening torque of 30 to 44 N·m. The main circuit is rated 690 V AC, and power loss is 30 W per pole at rated operating conditions. Dimensions are 193 mm wide, 255 mm high, and 230 mm deep, with a net weight of 6.7 kg. The product is classified under IEC 60947-3. Manufacturer ID 1SCA150268R1001. WEEE Category 5 applies. ETIM 8 and ETIM 9 classification is EC001040, fuse switch disconnector.
- OS400D22F
The ABB OS400D22F is a four-pole fuse protector with a rated current of 400 A in the main circuit and a rated operational voltage of 690 V AC. It is a front-operated, base-mounting device with DIN fuse system support for NH0, NH1, and NH2 fuse sizes. Terminal type is lug terminals, 25 mm wide, with a tightening torque of 30 to 44 N·m. Rated insulation voltage is 1000 V and rated impulse withstand voltage is 12 kV. The rated conditional short-circuit current is 80 kA at 690 V, and the rated short-time withstand current is 14 kA rms for 1 s. It conforms to IEC 60947-3. Handle and shaft are not included. Net dimensions are 319 mm width, 230 mm height, and 193 mm depth; net weight is 7.99 kg.
- OS400D22FP
ABB OS400D22FP fuse protector, four-pole, front-operated, base mounting. Rated current 400 A; rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV. Conventional free-air thermal current 400 A at 40 °C; conventional thermal current 400 A fully enclosed. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 14 kA rms for 1 s. DIN fuse system, fuse sizes NH0, NH1, NH2. Fourth pole switched-fusible. Lug terminals, 25 mm width, tightening torque 30 to 44 N·m. Pistol handle and shaft included. Pollution degree 3. Power loss 30 W per pole at rated operating conditions. Dimensions 318 mm width, 230 mm height, 193 mm depth; net weight 8.41 kg. Standard IEC 60947-3.
- OS400D22LR
ABB OS400D22LR fuse switch disconnector, four-pole, front-operated, base mounting. Rated current 400 A; rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV. Conventional free-air thermal current 400 A at 40 °C; conventional thermal current 630 A fully enclosed. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 14 kA rms for 1 s. Accepts NH0, NH1 and NH2 DIN fuses. Lug terminals, 25 mm wide, tightening torque 30 to 44 N·m. Power loss 40 W per pole at rated operating conditions. Pollution degree 3. Dimensions 407 x 200 x 255 mm; weight 12.8 kg. Complies with IEC 60947-3. Handle and shaft not included.