- OS250D22N2-60
The ABB OS250D22N2-60 is a 4-pole fuse protector for NH0 and NH1 DIN fuses, front operated and base mounted. The main circuit is rated 690 V AC, with a power loss of 13 W per pole at rated operating conditions. It uses lug terminals with a tightening torque of 30 to 44 N·m. Dimensions are 310 mm wide, 270 mm high, and 200 mm deep; net weight is 4.3 kg (9.5 lb). The device is classified under IEC 60947-3. Manufacturer ID: 1SCA022845R3650. ETIM 8 and ETIM 9 classification: EC001040, fuse switch disconnector. UNSPSC: 39122233. WEEE category 5, small equipment with no external dimension more than 50 cm.
- OS250D30-3
The ABB OS250D30-3 is a three-pole fuse protector for base mounting, front operated, with lug terminals. It accepts NH0 and NH1 fuses in the DIN fuse system. The main circuit is rated 690 V AC. Power loss is 13 W per pole at rated operating conditions. Terminal tightening torque is 30 to 44 N·m. Dimensions are 270 mm width, 230 mm height, and 170 mm depth; net weight is 3.5 kg (7.8 lb). The product is classified under IEC 60947-3. Manufacturer ID: 1SCA022745R8320. ETIM 8 and ETIM 9 classification is EC001040, fuse switch disconnector. UNSPSC is 39122233. WEEE category 5 covers small equipment with no external dimension more than 50 cm.
- OS250D30K
ABB fuse protector, display model OS250D30K, manufacturer ID 1SCA113110R1001. This is a front-operated, 3-pole fuse switch disconnector for base mounting, with DIN fuse system and NH0/NH1 fuse sizes. Rated operational voltage is 690 V AC for the main circuit. Power loss is 13 W per pole at rated operating conditions. Dimensions are 154 mm wide, 208 mm high, and 193 mm deep; net weight is 4.0 kg. Lug terminals accept a tightening torque of 30 to 44 N·m. The device is designed to IEC 60947-3. ETIM 8 and ETIM 9 classification is EC001040, fuse switch disconnector.
- OS250D30N3
ABB OS250D30N3 fuse protector, a 3+N pole front-operated switch fuse for base mounting. Rated current is 250 A in the main circuit, with rated operational voltage 690 V AC. Conventional free-air thermal current is 250 A at 40 °C, and conventional thermal current is 250 A fully enclosed. Rated insulation voltage is 1000 V, rated impulse withstand voltage is 12 kV, and rated conditional short-circuit current is 80 kA at 690 V. Rated short-time withstand current is 8 kA rms for 1 s. It accepts NH0 and NH1 DIN fuse sizes and uses lug terminals, 25 mm wide, tightened to 30 to 44 N·m. The fourth pole is a detachable neutral link integrated into the mechanism. Standards: IEC 60947-3. Handle and shaft are not included.
- OS250D40F
ABB OS250D40F fuse protector, four-pole, front-operated, base mounting. Rated current 250 A in the main circuit; rated operational voltage 690 V AC. Conventional free-air thermal current 250 A at 40 °C; conventional thermal current 250 A fully enclosed. Rated insulation voltage 1000 V, rated impulse withstand voltage 12 kV, rated conditional short-circuit current 80 kA at 690 V, and rated short-time withstand current 8 kA rms for 1 s. Accepts NH0 and NH1 DIN fuses; fourth pole is switched-fusible. Terminals are lug type, 25 mm wide, tightened to 30 to 44 N·m. Line terminals may be top-in/bottom-out or bottom-in/top-out. Dimensions 208 mm wide, 199 mm high, 154 mm deep; net weight 4.7 kg. Pollution degree 3. Conforms to IEC 60947-3. Handle and shaft not included.
- OS250D40FP
ABB OS250D40FP fuse protector, 4-pole, front-operated, base mounting, with pistol handle and shaft included. Rated current 250 A; rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV. Conventional free-air thermal current 250 A at 40 °C; conventional thermal current 250 A fully enclosed. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 8 kA rms for 1 s. Power loss 13 W per pole at rated operating conditions. Fuse system DIN, fuse sizes NH0 and NH1. Fourth pole switched-fusible. Lug terminals, 25 mm wide, tightening torque 30 to 44 N·m. Pollution degree 3. Dimensions 262 mm wide, 199 mm high, 154 mm deep; net weight 4.8 kg. Standards: IEC 60947-3.
- OS250D40N1
ABB fuse protector, model OS250D40N1, manufacturer ID 1SCA022726R9860. Four-pole, front-operated fuse switch disconnector for base mounting, rated 250 A in the main circuit and 690 V AC, with a rated insulation voltage of 1000 V and rated impulse withstand voltage of 12 kV. Conventional free-air thermal current is 250 A at 40 °C; enclosed thermal current is 250 A. Rated conditional short-circuit current is 80 kA at 690 V, and rated short-time withstand current is 8 kA rms for 1 s. Accepts NH0 and NH1 DIN fuses. Lug terminals, 25 mm wide, tightened to 30 to 44 N·m. Dimensions 262 mm wide, 199 mm high, 154 mm deep; 4.2 kg. Standards: IEC 60947-3. Handle and shaft not included.
- OS250D40N1P
ABB OS250D40N1P fuse protector, manufacturer ID 1SCA022726R8110. Four-pole front-operated fuse switch disconnector for base mounting, with pistol handle and shaft included. Rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV. Rated current 250 A in the main circuit, with conventional free-air thermal current 250 A at 40 °C and conventional thermal current 250 A fully enclosed. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 8 kA rms for 1 s. Fuse system DIN, fuse sizes NH0 and NH1. Lug terminals, 25 mm wide, tightening torque 30 to 44 N·m. Power loss 13 W per pole at rated operating conditions. Standards: IEC 60947-3.