- OS250D40N2
ABB OS250D40N2 is a four-pole fuse protector for base mounting, front operated, with line terminals configurable top in - bottom out or bottom in - top out. It accepts NH0 and NH1 fuses in the DIN fuse system. Rated current is 250 A in the main circuit; conventional free-air thermal current is 250 A at 40 °C, and conventional thermal current fully enclosed is 250 A. Rated operational voltage is 690 V AC, rated insulation voltage 1000 V, rated impulse withstand voltage 12 kV, and rated conditional short-circuit current at 690 V is 80 kA. It complies with IEC 60947-3. Dimensions are 206 mm width, 199 mm height, 154 mm depth; net weight 4.2 kg. Handle and shaft are not included.
- OS250D40N2-3
ABB fuse protector, model OS250D40N2-3, manufacturer ID 1SCA022756R3620. Four-pole, front-operated unit for base mounting with lug terminals. It accepts NH0 and NH1 fuses in the DIN fuse system. Rated operational voltage of the main circuit is 690 V AC, and power loss is 13 W per pole at rated operating conditions. Tightening torque for the terminals is 30 to 44 N·m. Product net weight is 4.65 kg. The unit is classified under IEC 60947-3. ETIM 8 and ETIM 9 classification is EC001040, fuse switch disconnector; UNSPSC code 39122233; IGCC 5291, fuse switch disconnector. WEEE Category 5, small equipment with no external dimension more than 50 cm.
- OS250DS03
ABB OS250DS03 is a 3-pole fuse protector, manufacturer ID 1SCA022860R3050, for base mounting with side operation. It accepts NH0 and NH1 fuses in the DIN system. Rated current of the main circuit is 250 A. Conventional free-air thermal current Ith is 250 A at 40 °C; conventional thermal current Ithe is 250 A fully enclosed. Rated insulation voltage Ui is 1000 V, rated impulse withstand voltage Uimp is 12 kV, and rated conditional short-circuit current Inc is 80 kA at 690 V. Power loss is 13 W per pole at rated operating conditions. Pollution degree is 3. Line terminals may be top in - bottom out or bottom in - top out. Net dimensions are 240 mm width, 199 mm height, and 154 mm depth; net weight is 3.7 kg. Handle and shaft are not included.
- OS250DS03K
ABB OS250DS03K fuse protector, manufacturer ID 1SCA022860R3130. Three-pole, side-operated switch fuse with a direct-mounted handle included and base mounting. Rated current of the main circuit is 250 A; conventional free-air thermal current is 250 A at 40 °C, and conventional thermal current fully enclosed is 250 A. Rated conditional short-circuit current is 80 kA at 690 V. Rated insulation voltage is 1000 V and rated impulse withstand voltage is 12 kV. Power loss is 13 W per pole at rated operating conditions. Fuse system is DIN, accepting NH0 and NH1 fuse sizes. Line terminals may be configured top in, bottom out or bottom in, top out. Dimensions are 240 mm wide, 199 mm high, and 154 mm deep; net weight is 3.8 kg. Pollution degree 3.
- OS250DS04F
The ABB OS250DS04F is a four-pole fuse switch disconnector for base mounting, side operated from the left. It accepts NH0 and NH1 DIN fuse links. Rated current for the main circuit is 250 A, with conventional free-air thermal current 250 A at 40 °C and fully enclosed thermal current 250 A. Rated operational voltage is 690 V AC; rated insulation voltage is 1000 V and rated impulse withstand voltage is 12 kV. Rated conditional short-circuit current is 80 kA at 690 V, and rated short-time withstand current is 8 kA rms for 1 s. Power loss is 13 W per pole at rated operating conditions. Terminals are lug type, 25 mm wide, tightened to 30 to 44 N·m. Pollution degree 3. Standards: IEC 60947-3. Dimensions: 294 mm width, 199 mm height, 154 mm depth; net weight 4.6 kg. Handle and shaft are not included.
- OS250DS04FK
ABB OS250DS04FK fuse switch disconnector, four-pole, side-operated with direct-mounted handle included. Rated current 250 A in the main circuit; conventional free-air thermal current 250 A at 40 °C and conventional thermal current 250 A fully enclosed. Rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 8 kA rms for 1 s. Accepts NH0 and NH1 DIN fuse sizes; fourth pole is switched-fusible. Lug terminals, 25 mm wide, tightened to 30 to 44 N·m. Power loss 13 W per pole at rated operating conditions. Pollution degree 3. Dimensions 294 mm wide, 199 mm high, 154 mm deep; net weight 4.7 kg. Conforms to IEC 60947-3.
- OS250DS04N2
ABB OS250DS04N2 is a four-pole fuse switch disconnector with side operation and a switched fourth pole on the right side using a solid link. It is rated 250 A in the main circuit, with conventional free-air thermal current 250 A at 40 °C and enclosed thermal current 250 A. Rated operational voltage is 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV. It accepts NH0 and NH1 fuses in the DIN system and is base mounted. Terminals are lug type, 25 mm wide, tightened to 30 to 44 N·m. Power loss is 13 W per pole at rated operating conditions. Handle and shaft are not included. Standards: IEC 60947-3.
- OS250DS20K
The ABB OS250DS20K is a two-pole fuse switch disconnector for base mounting, with side-operated actuation and lug terminals. It accepts NH0 and NH1 fuse sizes in the DIN fuse system. The main circuit is rated 690 V AC, and power loss is 13 W per pole at rated operating conditions. Terminal tightening torque is 30 to 44 N·m. Dimensions are 310 mm wide, 270 mm high, and 200 mm deep; net weight is 2.08 kg. The device is manufactured to IEC 60947-3. Manufacturer ID 1SCA143959R1001. Classification codes include ETIM EC001040 and UNSPSC 39122233.