- OS125GD12/B126
The ABB OS125GD12/B126 is a three-pole fuse switch disconnector for base mounting, front operated, with lug terminals. It accepts NH000 and NH00 DIN fuse sizes. The main circuit is rated 690 V AC, and power loss is 4 W per pole at rated operating conditions. Tightening torque for the terminals is 15 to 22 N·m. The device is manufactured to IEC 60947-3. Product net weight is 232 kg. The manufacturer ID is 1SCA156570R1001. It is classified under ETIM EC001040 as a fuse switch disconnector, UNSPSC 39122233, and IGCC 5291. WEEE category 5 applies.
- OS125GD12K
The ABB OS125GD12K is a three-pole fuse protector with a front-operated, direct-mounted handle and base mounting. It accepts NH000 and NH00 DIN fuse systems and uses lug terminals with a 20 mm terminal width and a tightening torque of 15 to 22 N·m. Rated current is 125 A in the main circuit, with conventional free-air thermal current of 125 A at 40 °C and conventional thermal current of 125 A fully enclosed. Rated operational voltage is 690 V AC, rated insulation voltage is 1000 V, and rated impulse withstand voltage is 8 kV. Rated conditional short-circuit current is 80 kA at 690 V. Power loss is 4 W per pole at rated operating conditions. It conforms to IEC 60947-3. Net dimensions are 190 mm wide, 170 mm high, and 210 mm deep; net weight is 2.04 kg.
- OS125GD12LR
ABB OS125GD12LR fuse switch disconnector, 3-pole, front-operated, base mounting. Rated current 125 A in the main circuit; conventional free-air thermal current 125 A at 40 °C and conventional thermal current 125 A fully enclosed. Rated operational voltage 690 V AC, rated insulation voltage 1000 V, rated impulse withstand voltage 8 kV. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 5 kA rms for 1 s. Accepts NH000 and NH00 DIN fuse links. Lug terminals, 20 mm wide, tightened to 15 to 22 N·m. Power loss 12 W per pole at rated operating conditions. Pollution degree 3. Dimensions 242 mm wide, 122 mm high, 156 mm deep; 2.4 kg. Standards: IEC 60947-3. Handle and shaft not included.
- OS125GD12LRP
ABB fuse protector, model OS125GD12LRP, manufacturer ID 1SCA120062R1001. Three-pole, front-operated fuse switch disconnector for base mounting with lug terminals, 20 mm terminal width, and tightening torque 15 to 22 N·m. Rated current 125 A in the main circuit; conventional free-air thermal current 125 A at 40 °C; conventional thermal current 125 A fully enclosed. Rated operational voltage 690 V AC, rated insulation voltage 1000 V, rated impulse withstand voltage 8 kV, pollution degree 3. Accepts NH000 and NH00 DIN fuses. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 5 kA rms for 1 s. Power loss 12 W per pole at rated operating conditions. Dimensions 242 mm wide, 122 mm high, 156 mm deep; net weight 2.9 kg. Standards: IEC 60947-3. Pistol handle and shaft included.
- OS125GD12P13
The ABB OS125GD12P13 is a front-operated, 3-pole fuse switch disconnector for base mounting. It accepts NH000 and NH00 fuses in a DIN fuse system and includes a handle and shaft. Rated current is 125 A in the main circuit, with conventional free-air thermal current 125 A at 40 °C and conventional thermal current 125 A fully enclosed. Rated operational voltage is 690 V AC; rated insulation voltage is 1000 V and rated impulse withstand voltage is 8 kV. Rated conditional short-circuit current is 80 kA at 690 V, and rated short-time withstand current is 5 kA rms for 1 s. Power loss is 4 W per pole at rated operating conditions. Lug terminals are 20 mm wide with 15 to 22 N·m tightening torque. Pollution degree 3. Standards: IEC 60947-3. Dimensions: 148 mm width, 140 mm height, 130 mm depth; net weight 2.035 kg.
- OS125GD13F
ABB fuse protector, model OS125GD13F, manufacturer ID 1SCA129102R1001. This four-pole fuse switch disconnector is front operated and base mounted, accepting NH000 and NH00 fuses in the DIN fuse system. It uses lug terminals with a tightening torque of 15 ... 22 N·m. Rated operational voltage of the main circuit is 690 V AC, with power loss at rated operating conditions per pole of 4 W. Dimensions are 130 mm wide, 183 mm high, and 140 mm deep; net weight is 2.4 kg. It is classified under IEC 60947-3.
- OS125GD13FP
The ABB OS125GD13FP is a four-pole fuse switch disconnector for base mounting with front operation. It accepts NH000 and NH00 DIN fuse links and includes a handle and shaft. Rated current is 125 A in the main circuit, with conventional free-air thermal current 125 A at 40 °C and enclosed thermal current 125 A. Rated operational voltage is 690 V AC; rated insulation voltage is 1000 V and rated impulse withstand voltage is 8 kV. Rated conditional short-circuit current is 80 kA at 690 V, and rated short-time withstand current is 5 kA rms for 1 s. Power loss is 4 W per pole at rated operating conditions. Dimensions are 130 mm wide, 183 mm high, and 140 mm deep; net weight is 2.6 kg. It conforms to IEC 60947-3.
- OS125GD13N1
The ABB OS125GD13N1 is a front-operated fuse switch disconnector supplied as a base-mounting unit. It has four poles and accepts NH000 or NH00 fuses in the DIN fuse system. The main circuit is rated 690 V AC, with a power loss of 4 W per pole at rated operating conditions. Lug terminals are provided, with a tightening torque of 15 to 22 N·m. Dimensions are 130 mm wide, 183 mm high, and 140 mm deep; net weight is 2.4 kg. The device is classified under IEC 60947-3. Manufacturer ID 1SCA149783R1001. The neutral pole is positioned on the left side. It is classified as ETIM EC001040 fuse switch disconnector.