- OS125GD13FP
The ABB OS125GD13FP is a four-pole fuse switch disconnector for base mounting with front operation. It accepts NH000 and NH00 DIN fuse links and includes a handle and shaft. Rated current is 125 A in the main circuit, with conventional free-air thermal current 125 A at 40 °C and enclosed thermal current 125 A. Rated operational voltage is 690 V AC; rated insulation voltage is 1000 V and rated impulse withstand voltage is 8 kV. Rated conditional short-circuit current is 80 kA at 690 V, and rated short-time withstand current is 5 kA rms for 1 s. Power loss is 4 W per pole at rated operating conditions. Dimensions are 130 mm wide, 183 mm high, and 140 mm deep; net weight is 2.6 kg. It conforms to IEC 60947-3.
- OS125GD13N1
The ABB OS125GD13N1 is a front-operated fuse switch disconnector supplied as a base-mounting unit. It has four poles and accepts NH000 or NH00 fuses in the DIN fuse system. The main circuit is rated 690 V AC, with a power loss of 4 W per pole at rated operating conditions. Lug terminals are provided, with a tightening torque of 15 to 22 N·m. Dimensions are 130 mm wide, 183 mm high, and 140 mm deep; net weight is 2.4 kg. The device is classified under IEC 60947-3. Manufacturer ID 1SCA149783R1001. The neutral pole is positioned on the left side. It is classified as ETIM EC001040 fuse switch disconnector.
- OS125GD13N2
The ABB OS125GD13N2 is a four-pole fuse protector with a front-operated mechanism and base mounting. It accepts NH000 and NH00 fuses in the DIN fuse system and uses lug terminals with a tightening torque of 15 to 22 N·m. The main circuit is rated for 690 V AC operation, and power loss is 4 W per pole at rated operating conditions. Dimensions are 130 mm wide, 183 mm high, and 140 mm deep, with a net weight of 2.4 kg. The product is classified under IEC 60947-3. Manufacturer ID: 1SCA123066R1001. ETIM 8 and ETIM 9 classification is EC001040, fuse switch disconnector.
- OS125GD13N2P
ABB OS125GD13N2P fuse switch disconnector, 4-pole, front-operated, base mounting. Rated current 125 A; rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 8 kV. Conventional free-air thermal current 125 A at 40 °C; enclosed thermal current 125 A. Rated conditional short-circuit current 80 kA at 690 V. Rated short-time withstand current 5 kA rms for 1 s. Power loss 4 W per pole at rated operating conditions. Fuse size NH000/NH00, DIN fuse system. Fourth pole switched with solid link, right side. Lug terminals, 20 mm width, tightening torque 15 to 22 N·m. Pistol handle and shaft included. Dimensions 183 x 140 x 130 mm; net weight 2.6 kg. Pollution degree 3. IEC 60947-3.
- OS125GD21
The ABB OS125GD21 is a 3-pole fuse switch disconnector for DIN fuse systems, accepting NH000 and NH00 fuse sizes. It is rated 125 A in the main circuit and 690 V AC, with a rated insulation voltage of 1000 V and a rated impulse withstand voltage of 8 kV. Rated conditional short-circuit current is 80 kA at 690 V, and rated short-time withstand current is 5 kA rms for 1 s. It is front operated with base mounting and lug terminals, 20 mm wide, tightened to 15 to 22 N·m. Power loss is 4 W per pole at rated operating conditions. Dimensions are 147 mm wide, 112 mm high, and 130 mm deep; net weight is 1.845 kg. Pollution degree is 3, conforming to IEC 60947-3. Handle and shaft are not included.
- OS125GD21-3
The ABB OS125GD21-3 is a front-operated, 3-pole fuse switch disconnector for base mounting. It accepts NH000 and NH00 fuses in a DIN fuse system and uses lug terminals with a tightening torque of 15 to 22 N·m. The main circuit is rated 690 V AC, and power loss is 4 W per pole at rated operating conditions. Dimensions are 220 mm wide, 170 mm high, and 150 mm deep; net weight is 1.675 kg. The device is classified under IEC 60947-3. Manufacturer ID: 1SCA122399R1001. ETIM 8 and ETIM 9 classification: EC001040 - Fuse switch disconnector.
- OS125GD21LR
ABB OS125GD21LR fuse switch disconnector, 3-pole, front-operated, base mounting. Rated current 125 A in the main circuit; conventional free-air thermal current 125 A at 40 °C and conventional thermal current 125 A fully enclosed. Rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 8 kV. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 5 kA rms for 1 s. Accepts NH000 and NH00 fuses in the DIN system. Line terminals left in, right out; lug terminals 20 mm wide; tightening torque 15 to 22 N·m. Power loss 12 W per pole at rated operating conditions. Pollution degree 3. Dimensions 242 x 122 x 156 mm; net weight 2.4 kg. Handle and shaft not included. Standards: IEC 60947-3.
- OS125GD21LRP
ABB OS125GD21LRP fuse switch disconnector, 3-pole, front-operated, base mounting. Rated current 125 A; rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 8 kV. Conventional free-air thermal current 125 A at 40 °C; conventional thermal current 125 A fully enclosed. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 5 kA rms for 1 s. Accepts NH000/NH00 DIN fuses. Lug terminals, 20 mm terminal width, tightening torque 15 to 22 N·m. Power loss 12 W per pole at rated operating conditions. Dimensions 242 mm width, 122 mm height, 156 mm depth; 2.9 kg. Pistol handle and shaft included. Pollution degree 3. Conforms to IEC 60947-3.