- OS1250D11
The ABB OS1250D11 is a two-pole fuse switch disconnector for base mounting, front operated, with line terminals configurable as top in/bottom out or bottom in/top out. It accepts NH4 DIN fuse systems. Rated current for the main circuit is 1250 A, with conventional free-air thermal current Ith of 1250 A at 40 °C and conventional thermal current Ithe of 1000 A fully enclosed. Rated operational voltage is 690 V AC; rated insulation voltage is 1000 V and rated impulse withstand voltage is 12 kV. Rated conditional short-circuit current is 80 kA at 690 V, and rated short-time withstand current Icw is 40 kA rms for 1 s. It conforms to IEC 60947-3. Net dimensions are 294 mm wide, 319 mm high, and 356 mm deep; net weight is 19.3 kg. Handle and shaft are not included.
- OS1250D11K
ABB OS1250D11K fuse switch disconnector, manufacturer ID 1SCA143375R1001. Two-pole, front-operated unit with direct-mounted handle and base mounting, accepting NH4 DIN fuse links. Main circuit rated 1250 A at 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV. Conventional free-air thermal current 1250 A at 40 °C; fully enclosed conventional thermal current 1000 A. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 40 kA rms for 1 s. Power loss 75 W per pole at rated operating conditions. Lug terminals, 50 mm terminal width, tightening torque 50 to 75 N·m. Pollution degree 3. Dimensions 365 mm wide, 322 mm high, 356 mm deep; net weight 21.1 kg. Conforms to IEC 60947-3.
- OS1250D12-3
The ABB OS1250D12-3 is a 3-pole DIN fuse switch disconnector for base mounting with front-operated actuation and lug terminals. It accepts NH4 fuse size and has a rated operational voltage of 690 V AC for the main circuit. Power loss is 75 W per pole at rated operating conditions. Terminal tightening torque is 50 to 75 N·m. It is classified under IEC 60947-3. The product net weight is 26.73 kg. ETIM 8 and ETIM 9 classification is EC001040, fuse switch disconnector. The manufacturer ID is 1SCA106303R1001. WEEE category 5 covers small equipment with no external dimension more than 50 cm.
- OS1250D12K
ABB OS1250D12K fuse protector, identified by manufacturer ID 1SCA149908R1001. It is a three-pole, front-operated fuse switch disconnector for base mounting with lug terminals. It accepts NH4 fuses in the DIN fuse system. The main circuit is rated 690 V AC, and power loss is 75 W per pole at rated operating conditions. Terminal tightening torque is 50 to 75 N·m. Dimensions are 365 mm wide, 429 mm high, and 356 mm deep; net weight is 29.2 kg. It is built to IEC 60947-3. Classification: ETIM EC001040 fuse switch disconnector.
- OS1250D22N1
ABB OS1250D22N1 fuse protector, manufacturer ID 1SCA141979R1001. Four-pole, front-operated fuse switch disconnector for DIN NH4 fuses, base mounting, with the fourth pole on the left side, switched with solid link. Rated current 1250 A; conventional free-air thermal current 1250 A at 40 °C; conventional thermal current 1000 A fully enclosed. Rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV; rated conditional short-circuit current 80 kA at 690 V; short-time withstand current 40 kA rms for 1 s. Power loss 75 W per pole at rated operating conditions. Pollution degree 3. Dimensions 294 mm wide, 542 mm high, 356 mm deep; 34.5 kg. Lug terminals, 50 mm wide, tightening torque 50 to 75 N·m. Standards: IEC 60947-3. Handle and shaft not included.
- OS1250D30
The ABB OS1250D30 is a three-pole fuse protector for base mounting, front operated, with NH4 fuses in a DIN fuse system. It measures 294 mm wide, 429 mm high, and 356 mm deep, and weighs 27.4 kg. The main circuit is rated 690 V AC, with power loss of 75 W per pole at rated operating conditions. It is manufactured to IEC 60947-3. Manufacturer ID: 1SCA125987R1001.
- OS1250D30K
The ABB OS1250D30K is a three-pole fuse switch disconnector with a direct-mounted, front-operated handle and base mounting. It accepts NH4 fuses in the DIN system and uses lug terminals with a 50 mm terminal width and 50 to 75 N·m tightening torque. Rated current is 1250 A in the main circuit, with conventional free-air thermal current 1250 A at 40 °C and fully enclosed thermal current 1000 A. Rated operational voltage is 690 V AC, rated insulation voltage 1000 V, rated impulse withstand voltage 12 kV, and rated conditional short-circuit current 80 kA at 690 V. It conforms to IEC 60947-3. Dimensions are 429 mm wide, 356 mm high, and 294 mm deep; net weight is 26.4 kg.
- OS1250D40FK
The ABB OS1250D40FK is a four-pole fuse switch disconnector with a direct-mounted, front-operated handle and base mounting. It is rated 1250 A in the main circuit at 690 V AC, with a conventional free-air thermal current of 1250 A at 40 °C and 1000 A fully enclosed. It accepts NH4 fuses in the DIN system and has lug terminals, 50 mm wide, tightened to 50 to 75 N·m. Rated insulation voltage is 1000 V, rated impulse withstand voltage is 12 kV, and rated conditional short-circuit current is 80 kA at 690 V. It conforms to IEC 60947-3. Dimensions are 539 mm wide, 356 mm high, and 294 mm deep; net weight is 36.495 kg.