- OS1250D22N1
ABB OS1250D22N1 fuse protector, manufacturer ID 1SCA141979R1001. Four-pole, front-operated fuse switch disconnector for DIN NH4 fuses, base mounting, with the fourth pole on the left side, switched with solid link. Rated current 1250 A; conventional free-air thermal current 1250 A at 40 °C; conventional thermal current 1000 A fully enclosed. Rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV; rated conditional short-circuit current 80 kA at 690 V; short-time withstand current 40 kA rms for 1 s. Power loss 75 W per pole at rated operating conditions. Pollution degree 3. Dimensions 294 mm wide, 542 mm high, 356 mm deep; 34.5 kg. Lug terminals, 50 mm wide, tightening torque 50 to 75 N·m. Standards: IEC 60947-3. Handle and shaft not included.
- OS1250D30
The ABB OS1250D30 is a three-pole fuse protector for base mounting, front operated, with NH4 fuses in a DIN fuse system. It measures 294 mm wide, 429 mm high, and 356 mm deep, and weighs 27.4 kg. The main circuit is rated 690 V AC, with power loss of 75 W per pole at rated operating conditions. It is manufactured to IEC 60947-3. Manufacturer ID: 1SCA125987R1001.
- OS1250D30K
The ABB OS1250D30K is a three-pole fuse switch disconnector with a direct-mounted, front-operated handle and base mounting. It accepts NH4 fuses in the DIN system and uses lug terminals with a 50 mm terminal width and 50 to 75 N·m tightening torque. Rated current is 1250 A in the main circuit, with conventional free-air thermal current 1250 A at 40 °C and fully enclosed thermal current 1000 A. Rated operational voltage is 690 V AC, rated insulation voltage 1000 V, rated impulse withstand voltage 12 kV, and rated conditional short-circuit current 80 kA at 690 V. It conforms to IEC 60947-3. Dimensions are 429 mm wide, 356 mm high, and 294 mm deep; net weight is 26.4 kg.
- OS1250D40FK
The ABB OS1250D40FK is a four-pole fuse switch disconnector with a direct-mounted, front-operated handle and base mounting. It is rated 1250 A in the main circuit at 690 V AC, with a conventional free-air thermal current of 1250 A at 40 °C and 1000 A fully enclosed. It accepts NH4 fuses in the DIN system and has lug terminals, 50 mm wide, tightened to 50 to 75 N·m. Rated insulation voltage is 1000 V, rated impulse withstand voltage is 12 kV, and rated conditional short-circuit current is 80 kA at 690 V. It conforms to IEC 60947-3. Dimensions are 539 mm wide, 356 mm high, and 294 mm deep; net weight is 36.495 kg.
- OS1250DA01
The ABB OS1250DA01 is a front-operated, single-pole fuse protector for base mounting, using DIN fuse system size NH4a with lug terminals. It is rated 1250 A in the main circuit and 690 V AC, with conventional free-air thermal current 1250 A at 40 °C and fully enclosed thermal current 1000 A. Rated insulation voltage is 1000 V and rated impulse withstand voltage is 12 kV. Rated conditional short-circuit current is 80 kA at 690 V, and rated short-time withstand current is 40 kA rms for 1 s. Cable cross-section is 2.5 to 25 mm², tightening torque 50 to 75 N·m, power loss 75 W per pole at rated operating conditions, pollution degree 3, and IEC 60947-3. Handle and shaft are not included. Dimensions are 294 mm wide, 209 mm high, and 356 mm deep; net weight 10.9 kg.
- OS1250DA01P
ABB OS1250DA01P is a 1-pole DIN fuse switch disconnector for base mounting with front operation and a left-side 01 operating mechanism. It accepts NH4a fuse links and uses lug terminals 50 mm wide with a tightening torque of 50 to 75 N·m. Rated current is 1250 A in the main circuit; conventional free-air thermal current Ith is 1250 A at 40 °C, and fully enclosed thermal current Ithe is 1000 A. Rated operational voltage is 690 V AC, rated insulation voltage 1000 V, rated impulse withstand voltage 12 kV, and rated conditional short-circuit current 80 kA at 690 V. It conforms to IEC 60947-3. Net dimensions are 294 mm wide, 209 mm high, and 356 mm deep; net weight is 11.9 kg. A handle and shaft are included.
- OS1250DA02
ABB OS1250DA02 fuse switch disconnector, category fuse protector, manufacturer ID 1SCA114058R1001. Two-pole, front-operated, base-mounting unit for NH4a DIN fuses, with line terminals configurable top-in/bottom-out or bottom-in/top-out. Rated current 1250 A; rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV. Conventional free-air thermal current 1250 A at 40 °C; conventional thermal current 1000 A fully enclosed. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 40 kA rms for 1 s. Power loss 75 W per pole at rated operating conditions. Lug terminals, 50 mm terminal width, cable cross-section 2.5 to 25 mm², tightening torque 50 to 75 N·m. Pollution degree 3. Standards: IEC 60947-3. Handle and shaft not included. Net dimensions 325 mm width, 356 mm height, 294 mm depth; net weight 19.04 kg.
- OS1250DA03N3P
ABB fuse protector, model OS1250DA03N3P, manufacturer ID 1SCA107934R1001. Three-pole plus detachable neutral link integrated into the mechanism (3+N), front-operated, base mounting, with handle and shaft included. Rated current 1250 A in the main circuit; conventional free-air thermal current 1250 A at 40 °C; conventional thermal current 1000 A fully enclosed. Rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV. Rated conditional short-circuit current 80 kA at 690 V. Rated short-time withstand current 40 kA rms for 1 s. NH4a DIN fuse size, lug terminals 50 mm wide, tightening torque 50 to 75 N·m. Pollution degree 3. Standards: IEC 60947-3. Net dimensions 429 x 356 x 366 mm; net weight 46 kg.