- OS1250DA03N3P
ABB fuse protector, model OS1250DA03N3P, manufacturer ID 1SCA107934R1001. Three-pole plus detachable neutral link integrated into the mechanism (3+N), front-operated, base mounting, with handle and shaft included. Rated current 1250 A in the main circuit; conventional free-air thermal current 1250 A at 40 °C; conventional thermal current 1000 A fully enclosed. Rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV. Rated conditional short-circuit current 80 kA at 690 V. Rated short-time withstand current 40 kA rms for 1 s. NH4a DIN fuse size, lug terminals 50 mm wide, tightening torque 50 to 75 N·m. Pollution degree 3. Standards: IEC 60947-3. Net dimensions 429 x 356 x 366 mm; net weight 46 kg.
- OS1250DA04F
ABB fuse switch disconnector, model OS1250DA04F, manufacturer ID 1SCA105239R1001. Four-pole, front-operated unit with base mounting and a switched-fusible fourth pole. It accepts NH4a DIN fuse links. Rated current is 1250 A for the main circuit; conventional free-air thermal current is 1250 A at 40 °C, and conventional thermal current in a fully enclosed installation is 1000 A. Rated operational voltage is 690 V AC, rated insulation voltage 1000 V, and rated impulse withstand voltage 12 kV. Rated conditional short-circuit current is 80 kA at 690 V. Power loss is 75 W per pole at rated operating conditions. Dimensions are 539 mm wide, 356 mm high, and 294 mm deep; net weight is 35 kg. Handle and shaft are not included.
- OS1250DA04FP
ABB OS1250DA04FP fuse protector, four-pole, front-operated, base mounting, with switched fusible fourth pole. Rated current 1250 A in the main circuit; conventional free-air thermal current 1250 A at 40 °C and conventional thermal current 1000 A fully enclosed. Rated operational voltage 690 V AC, rated insulation voltage 1000 V, rated impulse withstand voltage 12 kV, pollution degree 3. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 40 kA rms for 1 s. Fuse size NH4a, DIN fuse system. Lug terminals, 50 mm terminal width, tightening torque 50 to 75 N·m. Pistol handle and shaft included. Dimensions 539 mm wide, 356 mm high, 366 mm deep; net weight 35.96 kg. Standards: IEC 60947-3.
- OS1250DA04N2
ABB fuse switch disconnector OS1250DA04N2, four-pole, base mounting, front operated. Main circuit rated current 1250 A at rated operational voltage 690 V AC; conventional free-air thermal current 1250 A at 40 °C, and 1000 A fully enclosed. Rated insulation voltage 1000 V, rated impulse withstand voltage 12 kV, rated conditional short-circuit current 80 kA at 690 V, and short-time withstand current 40 kA rms for 1 s. Fuse system DIN, fuse size NH4a. Fourth pole is switched with solid link, right side. Lug terminals, 50 mm terminal width, tightening torque 50 to 75 N·m. Power loss 75 W per pole at rated operating conditions. Pollution degree 3. Dimensions 539 mm wide, 356 mm high, 294 mm deep; net weight 34 kg. Standards: IEC 60947-3. Handle and shaft not included.
- OS1250DA11
The ABB OS1250DA11 is a two-pole fuse protector for base mounting with front operation and an 11-position operating mechanism between the poles. It accepts NH4a DIN fuses and provides lug terminals 50 mm wide with a tightening torque of 50 to 75 N·m. Rated insulation voltage is 1000 V, rated impulse withstand voltage is 12 kV, and the main circuit is rated 690 V AC at 1250 A. Conventional free-air thermal current is 1250 A at 40 °C; fully enclosed conventional thermal current is 1000 A. Rated conditional short-circuit current is 80 kA at 690 V, and rated short-time withstand current is 40 kA rms for 1 s. Power loss is 75 W per pole at rated operating conditions. Pollution degree 3. Complies with IEC 60947-3. Handle and shaft not included. Net dimensions 294 x 322 x 356 mm; net weight 20.1 kg.
- OS1250DA11K
ABB OS1250DA11K fuse switch disconnector, 2-pole, front-operated with direct-mounted handle, base mounting. Rated current 1250 A in the main circuit; rated operational voltage 690 V AC. Conventional free-air thermal current 1250 A at 40 °C; fully enclosed thermal current 1000 A. Rated insulation voltage 1000 V, rated impulse withstand voltage 12 kV, rated conditional short-circuit current 80 kA at 690 V, and short-time withstand current 40 kA rms for 1 s. Accepts NH4a DIN fuse links. Lug terminals, 50 mm terminal width, tightening torque 50 to 75 N·m. Pollution degree 3. Power loss 75 W per pole at rated operating conditions. Dimensions 365 mm width, 322 mm height, 356 mm depth; net weight 21.9 kg. Conforms to IEC 60947-3.
- OS1250DA12-3
The ABB OS1250DA12-3 is a three-pole fuse switch disconnector for base mounting with front operation. It accepts NH4a fuses in the DIN system and uses lug terminals tightened to 50 ... 75 N·m. The main circuit is rated 690 V AC, and power loss at rated operating conditions is 75 W per pole. The product net weight is 26.725 kg. It is classified under IEC 60947-3 and carries ETIM 8 and ETIM 9 category EC001040, UNSPSC 39122233, and IGCC 5291. The manufacturer identifier is 1SCA105771R1001. WEEE category 5 covers small equipment with no external dimension more than 50 cm.
- OS1250DA21
ABB OS1250DA21 fuse switch disconnector, 3-pole, front-operated, base mounting, for DIN fuse system with NH4a fuse size. Rated current 1250 A in the main circuit; conventional free-air thermal current 1250 A at 40 °C and conventional thermal current 1000 A fully enclosed. Rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 40 kA rms for 1 s. Cable cross-section 2.5 to 25 mm²; lug terminals 50 mm wide; tightening torque 50 to 75 N·m. Pollution degree 3. Dimensions 432 x 356 x 294 mm; net weight 27.02 kg. Handle and shaft not included. Conforms to IEC 60947-3.