- OS1250DA21P
The ABB OS1250DA21P is a 3-pole, front-operated fuse switch disconnector for DIN fuse systems, using NH4a fuse size. It is rated 1250 A in the main circuit and 690 V AC, with conventional free-air thermal current 1250 A at 40 °C and fully enclosed thermal current 1000 A. Rated insulation voltage is 1000 V and rated impulse withstand voltage is 12 kV. Rated conditional short-circuit current is 80 kA at 690 V; rated short-time withstand current is 40 kA rms for 1 s. Power loss is 75 W per pole at rated operating conditions. It uses lug terminals with 50 mm terminal width, accepts cable cross-sections from 2.5 to 25 mm², and requires tightening torque of 50 to 75 N·m. Pollution degree 3. Standards: IEC 60947-3. Dimensions are 432 mm wide, 356 mm high, and 294 mm deep; net weight is 27.98 kg.
- OS125BS40N1W
ABB OS125BS40N1W fuse protector, manufacturer ID 1SCA022552R4220. Four-pole, side-operated switch fuse disconnector for British Standard fuse systems, accepting A2, A3, and A4 fuse sizes. Rated operational voltage is 690 V AC. Conventional free-air thermal current Ith is 125 A at 40 °C; conventional thermal current Ithe is 125 A fully enclosed. Rated operational current is 125 A at 380 to 415 V, 500 V, and 690 V for AC-21A, AC-22A, AC-23B, and at 380 to 415 V and 500 V for AC-23A. Rated operational power AC-23A is 37 kW at 220 to 240 V, 55 kW at 400 V, 415 V, and 500 V, and 110 kW at 690 V. Power loss is 5 W per pole at rated operating conditions. Dimensions are 229 mm width, 144 mm height, 113 mm depth, 1.80 kg. Handle not included.
- OS125F22FW
ABB OS125F22FW is a four-pole fuse protector with a 22x58 fuse size and NFC fuse system. It is front operated, with line terminals configurable as top in/bottom out or bottom in/top out. The handle is not included. Conventional free-air thermal current Ith is 125 A at 40 °C; conventional thermal current Ithe is 125 A fully enclosed. Rated operational current is 125 A at 380–415 V, 500 V, and 690 V for AC-21A, AC-22A, and AC-23B, and at 380–415 V and 500 V for AC-23A. Rated operational power AC-23A is 37 kW at 220–240 V, 55 kW at 400 V, 415 V, and 500 V, and 110 kW at 690 V. Power loss is 5 W per pole at rated operating conditions. Dimensions are 215 mm wide, 144 mm high, and 113 mm deep; net weight is 1.80 kg. Manufacturer ID: 1SCA022552R2360.
- OS125GB02
The ABB OS125GB02 is a two-pole fuse protector with base mounting and front operation. It accepts British Standard fuses in sizes A2-A4 and uses lug terminals 20 mm wide, tightened to 15 to 22 N·m. Rated current is 125 A in the main circuit, with conventional free-air thermal current 125 A at 40 °C and conventional thermal current 125 A fully enclosed. Rated operational voltage is 690 V AC; rated insulation voltage is 1000 V and rated impulse withstand voltage is 8 kV. Rated conditional short-circuit current is 80 kA at 690 V, and rated short-time withstand current is 5 kA rms for 1 s. Power loss is 4 W per pole at rated operating conditions. Pollution degree 3. Dimensions are 112 mm wide, 140 mm high, and 115 mm deep; net weight 1.36 kg. Standards: IEC 60947-3. Handle and shaft are not included.
- OS125GB02P
The ABB OS125GB02P is a base-mounted fuse switch disconnector with two poles, front-operated via an included pistol handle and shaft. It is rated 125 A in the main circuit, with conventional free-air thermal current 125 A at 40 °C and enclosed thermal current 125 A. Rated operational voltage is 690 V AC; rated insulation voltage is 1000 V and rated impulse withstand voltage is 8 kV. It accepts British Standard fuses in sizes A2-A4 and uses lug terminals 20 mm wide, tightened to 15 to 22 N·m. Power loss is 4 W per pole at rated operating conditions. The unit measures 112 mm wide, 140 mm high and 115 mm deep, weighs 1.56 kg, and is rated to IEC 60947-3.
- OS125GB03
The ABB OS125GB03 is a three-pole fuse switch disconnector with a rated current of 125 A in the main circuit and a rated operational voltage of 690 V AC. It is designed for base mounting with front operation and accepts British Standard fuses in sizes A2-A4. Lug terminals accommodate cable cross-sections from 2.5 to 25 mm², with a tightening torque of 15 to 22 N·m. The rated insulation voltage is 1000 V, rated impulse withstand voltage is 8 kV, and rated conditional short-circuit current is 80 kA at 690 V. It conforms to IEC 60947-3. Dimensions are 147 mm wide, 140 mm high, and 115 mm deep, weighing 1.835 kg. Handle and shaft are not included.
- OS125GB03-42
ABB OS125GB03-42 fuse switch disconnector, 3-pole, front-operated, base mounting. Rated current 125 A; rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 8 kV. Conventional free-air thermal current 125 A at 40 °C; fully enclosed thermal current 125 A. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 5 kA rms for 1 s. Rated operational power AC-23A: 37 kW at 220–240 V, 55 kW at 400 V and 415 V, 75 kW at 500 V, 110 kW at 690 V. Fuse system British Standard, fuse size A2–A4. Lug terminals, 20 mm width, tightening torque 15–22 N·m. Pollution degree 3. Standards: IEC 60947-3. Handle and shaft not included. Dimensions 146.5 mm wide, 172 mm high, 114.5 mm deep; net weight 1.87 kg.
- OS125GB03BB
ABB OS125GB03BB is a three-pole fuse switch disconnector for base mounting, front operated, with back-in/back-out line terminals. The main circuit is rated 690 V AC and 125 A, with a rated insulation voltage of 1000 V and rated impulse withstand voltage of 8 kV. Conventional free-air thermal current is 125 A at 40 °C; conventional thermal current fully enclosed is 125 A. Rated conditional short-circuit current is 80 kA at 690 V, and rated short-time withstand current is 5 kA rms for 1 s. Fuse system is British Standard, fuse size A2-A4. Power loss is 4 W per pole at rated operating conditions. Lug terminals are 20 mm wide, tightening torque 15 to 22 N·m. Pollution degree 3. Standards: IEC 60947-3. Handle and shaft not included. Net dimensions 137 mm x 151 mm x 118 mm; net weight 1.9 kg.