- OS400DS30
ABB OS400DS30 is a 3-pole fuse protector for DIN fuse systems, accepting NH0, NH1, and NH2 fuse sizes. It is base mounted and side operated; handle and shaft are not included. The main circuit rated current is 400 A, with conventional free-air thermal current Ith of 400 A at 40 °C and conventional thermal current Ithe of 400 A fully enclosed. Rated insulation voltage is 1000 V, rated impulse withstand voltage is 12 kV, and rated conditional short-circuit current is 80 kA at 690 V. Power loss is 30 W per pole at rated operating conditions. Line terminals may be top in, bottom out or bottom in, top out. Pollution degree 3. Dimensions are 288 mm wide, 230 mm high, and 193 mm deep; net weight is 6.675 kg. Manufacturer ID: 1SCA022871R2850.
- OS400DS30K
ABB OS400DS30K is a 3-pole fuse protector for base mounting with side operation and a direct mounted handle included. It accepts DIN fuse system sizes NH0, NH1, and NH2. The main circuit rated current is 400 A, with conventional free-air thermal current Ith 400 A at 40 °C and conventional thermal current Ithe 400 A fully enclosed. Rated insulation voltage is 1000 V and rated impulse withstand voltage is 12 kV. Rated conditional short-circuit current is 80 kA at 690 V. Power loss is 30 W per pole at rated operating conditions. Line terminals may be configured top in - bottom out or bottom in - top out. Dimensions are 288 mm wide, 230 mm high, and 193 mm deep; net weight is 6.82 kg. Pollution degree 3. Manufacturer ID 1SCA022871R2930.
- OS400DS40F
The ABB OS400DS40F is a four-pole fuse switch disconnector for base mounting with side operation. It is rated 400 A and 690 V AC in the main circuit, with a rated insulation voltage of 1000 V and a rated impulse withstand voltage of 12 kV. Conventional free-air thermal current is 400 A at 40 °C; enclosed thermal current is 400 A. It accepts NH0, NH1, and NH2 DIN fuses, and the fourth pole is switched and fusible. Terminal type is lug terminals, 25 mm wide, with tightening torque 30 to 44 N·m. Power loss is 30 W per pole at rated operating conditions. It conforms to IEC 60947-3. Handle and shaft are not included.
- OS400DS40FK
ABB OS400DS40FK fuse switch disconnector, four-pole, side-operated, base mounting, with direct-mounted handle included. Rated current 400 A; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV; rated operational voltage 690 V AC. Conventional free-air thermal current 400 A at 40 °C; conventional thermal current 400 A fully enclosed. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 14 kA rms for 1 s. Accepts NH0, NH1, and NH2 fuses in DIN fuse system. Lug terminals, 25 mm terminal width, tightening torque 30 to 44 N·m. Power loss 30 W per pole at rated operating conditions. Pollution degree 3. Standards: IEC 60947-3. Dimensions 352 mm wide, 230 mm high, 193 mm deep; net weight 8.595 kg.
- OS400DS40N2
The ABB OS400DS40N2 is a four-pole fuse switch disconnector for base mounting, side operated, with line terminals configurable as top in/bottom out or bottom in/top out. It accepts NH0, NH1, and NH2 fuses in the DIN fuse system. Rated current is 400 A in the main circuit; conventional free-air thermal current Ith is 400 A at 40 °C, and conventional thermal current Ithe is 400 A fully enclosed. Rated operational voltage is 690 V AC, rated insulation voltage Ui is 1000 V, rated impulse withstand voltage Uimp is 12 kV, and rated conditional short-circuit current Inc is 80 kA at 690 V. It conforms to IEC 60947-3. Net dimensions are 352 mm wide, 230 mm high, and 193 mm deep; net weight is 8.655 kg. Handle and shaft are not included.
- OS400J02
The ABB OS400J02 is a 2-pole fuse protector for base mounting with front operation. It uses Class J fuses rated 400 A and accepts lug terminals 25 mm wide, tightened to 30 to 44 N·m. Rated operational voltage is 600 V AC; rated insulation voltage is 1000 V and rated impulse withstand voltage is 12 kV. Conventional free-air thermal current is 400 A at 40 °C, and enclosed thermal current is 400 A. Rated conditional short-circuit current is 80 kA at 690 V, and rated short-time withstand current is 14 kA rms for 1 s. Power loss is 30 W per pole at rated operating conditions. Standards: UL98, IEC 60947-3. Dimensions are 191 mm wide, 230 mm high, 176 mm deep; net weight 5.6 kg. Handle and shaft are not included.
- OS400J03K
ABB OS400J03K fuse protector, identified by manufacturer ID 1SCA117773R1001. It is a three-pole, front-operated fusible switch disconnector for base mounting with lug terminals. The main circuit is rated 400 A at 600 V AC, with a rated impulse withstand voltage of 12 kV and a rated conditional short-circuit current of 80 kA at 690 V AC. It accepts Class J fuses rated 400 A. Power loss is 30 W per pole at rated operating conditions. Tightening torque is 30 to 44 N·m. Dimensions are 360 mm wide, 365 mm high, and 175 mm deep; net weight is 6.55 kg. Standards: UL98 and IEC 60947-3.
- OS400J12
ABB OS400J12 is a 3-pole fuse protector for Class J fuses rated 400 A, intended for base mounting with front operation. It has a rated current (In) of 400 A in the main circuit, a conventional free-air thermal current (Ith) of 400 A at 40 °C, and a conventional thermal current (Ithe) of 400 A fully enclosed. Rated insulation voltage (Ui) is 1000 V and rated impulse withstand voltage (Uimp) is 12 kV. Rated conditional short-circuit current (Inc) is 80 kA at 690 V. Power loss is 30 W per pole at rated operating conditions. Dimensions are 254 mm wide, 230 mm high, and 176 mm deep; net weight is 6.4 kg. Pollution degree 3. Line terminals may be top in/bottom out or bottom in/top out. Handle and shaft are not included. Manufacturer ID 1SCA022755R3150.