- OS400DS40N2
The ABB OS400DS40N2 is a four-pole fuse switch disconnector for base mounting, side operated, with line terminals configurable as top in/bottom out or bottom in/top out. It accepts NH0, NH1, and NH2 fuses in the DIN fuse system. Rated current is 400 A in the main circuit; conventional free-air thermal current Ith is 400 A at 40 °C, and conventional thermal current Ithe is 400 A fully enclosed. Rated operational voltage is 690 V AC, rated insulation voltage Ui is 1000 V, rated impulse withstand voltage Uimp is 12 kV, and rated conditional short-circuit current Inc is 80 kA at 690 V. It conforms to IEC 60947-3. Net dimensions are 352 mm wide, 230 mm high, and 193 mm deep; net weight is 8.655 kg. Handle and shaft are not included.
- OS400J02
The ABB OS400J02 is a 2-pole fuse protector for base mounting with front operation. It uses Class J fuses rated 400 A and accepts lug terminals 25 mm wide, tightened to 30 to 44 N·m. Rated operational voltage is 600 V AC; rated insulation voltage is 1000 V and rated impulse withstand voltage is 12 kV. Conventional free-air thermal current is 400 A at 40 °C, and enclosed thermal current is 400 A. Rated conditional short-circuit current is 80 kA at 690 V, and rated short-time withstand current is 14 kA rms for 1 s. Power loss is 30 W per pole at rated operating conditions. Standards: UL98, IEC 60947-3. Dimensions are 191 mm wide, 230 mm high, 176 mm deep; net weight 5.6 kg. Handle and shaft are not included.
- OS400J03K
ABB OS400J03K fuse protector, identified by manufacturer ID 1SCA117773R1001. It is a three-pole, front-operated fusible switch disconnector for base mounting with lug terminals. The main circuit is rated 400 A at 600 V AC, with a rated impulse withstand voltage of 12 kV and a rated conditional short-circuit current of 80 kA at 690 V AC. It accepts Class J fuses rated 400 A. Power loss is 30 W per pole at rated operating conditions. Tightening torque is 30 to 44 N·m. Dimensions are 360 mm wide, 365 mm high, and 175 mm deep; net weight is 6.55 kg. Standards: UL98 and IEC 60947-3.
- OS400J12
ABB OS400J12 is a 3-pole fuse protector for Class J fuses rated 400 A, intended for base mounting with front operation. It has a rated current (In) of 400 A in the main circuit, a conventional free-air thermal current (Ith) of 400 A at 40 °C, and a conventional thermal current (Ithe) of 400 A fully enclosed. Rated insulation voltage (Ui) is 1000 V and rated impulse withstand voltage (Uimp) is 12 kV. Rated conditional short-circuit current (Inc) is 80 kA at 690 V. Power loss is 30 W per pole at rated operating conditions. Dimensions are 254 mm wide, 230 mm high, and 176 mm deep; net weight is 6.4 kg. Pollution degree 3. Line terminals may be top in/bottom out or bottom in/top out. Handle and shaft are not included. Manufacturer ID 1SCA022755R3150.
- OS400J12P
ABB OS400J12P fuse protector, a three-pole Class J fusible disconnect switch. Rated current 400 A in the main circuit; rated operational voltage 600 V AC. Conventional free-air thermal current 400 A at 40 °C; fully enclosed thermal current 400 A. Rated insulation voltage 1000 V, rated impulse withstand voltage 12 kV, rated conditional short-circuit current 80 kA at 690 V, and short-time withstand current 14 kA rms for 1 s. Power loss 30 W per pole at rated operating conditions. Horsepower ratings per UL: 125 Hp at 240 V, 250 Hp at 480 V, 350 Hp at 600 V. Standards: UL98, IEC 60947-3. Dimensions 254 mm wide, 230 mm high, 176 mm deep; net weight 7.3 kg. Base mounting, front-operated pistol handle and shaft included, lug terminals, 25 mm terminal width, tightening torque 30 to 44 N·m.
- OS400J21
The ABB OS400J21 is a 3-pole, front-operated switch fuse for base mounting. It has a rated current (In) of 400 A in the main circuit, a conventional free-air thermal current (Ith) of 400 A at 40 °C, and a conventional thermal current (Ithe) of 400 A fully enclosed. It uses a Class J fuse system with a 400 A fuse size. Rated insulation voltage (Ui) is 1000 V, rated impulse withstand voltage (Uimp) is 12 kV, and rated conditional short-circuit current (Inc) is 80 kA at 690 V. Power loss is 30 W per pole at rated operating conditions. Pollution degree is 3. Dimensions are 254 mm wide, 230 mm high, and 176 mm deep; net weight is 6.4 kg. Line terminals may be top in/bottom out or bottom in/top out. Handle and shaft are not included.
- OS400J21P
ABB OS400J21P fuse switch disconnector, three-pole, front-operated, base mounting. Rated current 400 A in the main circuit; fuse size 400 A, Class J fuse system. Conventional free-air thermal current Ith 400 A at 40 °C; conventional thermal current Ithe 400 A fully enclosed. Rated insulation voltage Ui 1000 V; rated impulse withstand voltage Uimp 12 kV; rated operational voltage 600 V AC. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 14 kA rms for 1 s. Power loss 30 W per pole at rated operating conditions. Lug terminals, 25 mm terminal width, tightening torque 30 to 44 N·m. Pollution degree 3. Dimensions 254 mm wide, 230 mm high, 176 mm deep; net weight 7.3 kg. Standards UL98, IEC 60947-3.
- OS400J22F
The ABB OS400J22F is a four-pole fuse switch disconnector for base mounting, front operated, with a switched-fusible fourth pole. It accepts Class J fuses rated 400 A. Rated current (In) is 400 A in the main circuit; conventional free-air thermal current (Ith) is 400 A at 40 °C, and conventional thermal current (Ithe) is 400 A fully enclosed. Rated insulation voltage (Ui) is 1000 V, rated impulse withstand voltage (Uimp) is 12 kV, and rated conditional short-circuit current (Inc) is 80 kA at 690 V. It is rated 600 V AC, with AC-23A operational power of 400 kW at 690 V. Standards: UL98 and IEC 60947-3. Dimensions are 318 mm wide, 230 mm high, and 176 mm deep; net weight is 7.99 kg. Handle and shaft are not included.