- OS630D04N1
The ABB OS630D04N1 is a four-pole fuse switch disconnector for base mounting, front operated, with a switched fourth pole on the left side using a solid link. It accepts NH3 DIN fuses. Rated current is 630 A; conventional free-air thermal current is 630 A at 40 °C, and fully enclosed conventional thermal current is 570 A. Rated operational voltage is 690 V AC, rated insulation voltage 1000 V, and rated impulse withstand voltage 12 kV. Rated conditional short-circuit current is 80 kA at 690 V. Power loss is 46 W per pole at rated operating conditions. Dimensions are 431 mm wide, 306 mm high, and 233 mm deep; net weight is 18.54 kg. Handle and shaft are not included. Standards: IEC 60947-3.
- OS630D04N1P
ABB fuse protector, model OS630D04N1P. Four-pole, front-operated fuse switch disconnector with base mounting, pistol handle and shaft included. Main circuit rated current 630 A at rated operational voltage 690 V AC. Conventional free-air thermal current 630 A at 40 °C; fully enclosed thermal current 570 A. Rated insulation voltage 1000 V, rated impulse withstand voltage 12 kV, rated conditional short-circuit current 80 kA at 690 V. Short-time withstand current 18 kA rms for 1 s. Fuse size NH3, DIN fuse system. Lug terminals, 39 mm wide, tightening torque 50 to 75 N·m. Dimensions 431 mm wide, 306 mm high, 233 mm deep; net weight 19.04 kg. Standards: IEC 60947-3.
- OS630D11
The ABB OS630D11 is a two-pole fuse protector with a front-operated mechanism and base mounting. It accepts NH3 fuses in the DIN fuse system and uses lug terminals with a terminal width of 39 mm and a tightening torque of 50 to 75 N·m. The main circuit is rated 630 A at 690 V AC, with a rated insulation voltage of 1000 V, a rated impulse withstand voltage of 12 kV, and a rated conditional short-circuit current of 80 kA at 690 V. Conventional free-air thermal current is 630 A at 40 °C; enclosed thermal current is 570 A. It conforms to IEC 60947-3. Dimensions are 253 mm wide, 306 mm high, and 233 mm deep; net weight is 10.06 kg. Handle and shaft are not included.
- OS630D11K
The ABB OS630D11K is a two-pole fuse switch disconnector for DIN NH3 fuse systems, front-operated with a direct-mounted handle and base mounting. The main circuit is rated 690 V AC, 630 A, with a rated insulation voltage of 1000 V and a rated impulse withstand voltage of 12 kV. Conventional free-air thermal current is 630 A at 40 °C; enclosed thermal current is 570 A. Rated conditional short-circuit current is 80 kA at 690 V, and short-time withstand current is 18 kA rms for 1 s. Power loss is 46 W per pole at rated operating conditions. Lug terminals accept 39 mm width and tighten to 50 to 75 N·m. Dimensions are 279 mm wide, 253 mm high, and 306 mm deep; weight is 10.6 kg. It conforms to IEC 60947-3.
- OS630D12-3
ABB fuse protector, display model OS630D12-3, manufacturer ID 1SCA101444R1001. This is a three-pole, front-operated fuse switch disconnector for base mounting with lug terminals. It accepts NH2 and NH3 fuses in a DIN fuse system. The main circuit is rated 690 V AC. Power loss is 46 W per pole at rated operating conditions. Terminal tightening torque is 50 to 75 N·m. The device conforms to IEC 60947-3. Product net weight is 13.63 kg. ETIM 8 and ETIM 9 classification is EC001040, fuse switch disconnector. UNSPSC code is 39122233; IDEA granular category code is 5291, fuse switch disconnector. WEEE category 5 applies.
- OS630D12-60
The ABB OS630D12-60 is a 3-pole fuse protector for base mounting with front operation. It accepts NH2 and NH3 fuses in a DIN fuse system and uses lug terminals. The main circuit is rated 690 V AC, with power loss of 46 W per pole at rated operating conditions. Dimensions are 365 mm wide, 328 mm high, and 260 mm deep; net weight is 13.445 kg. Terminal tightening torque is 50 to 75 N·m. The product is classified under IEC 60947-3. Manufacturer ID: 1SCA022864R9470. ETIM 8 and ETIM 9 classification is EC001040, fuse switch disconnector.
- OS630D13F
The ABB OS630D13F is a four-pole fuse protector with a switched-fusible fourth pole, rated 630 A in the main circuit and 690 V AC. It uses NH3 DIN fuses, base mounting, front operation, and lug terminals with 39 mm terminal width and 50 to 75 N·m tightening torque. Conventional free-air thermal current is 630 A at 40 °C; enclosed thermal current is 570 A. Rated conditional short-circuit current is 80 kA at 690 V, rated short-time withstand current is 18 kA rms for 1 s, rated impulse withstand voltage is 12 kV, and rated insulation voltage is 1000 V. Power loss is 46 W per pole at rated operating conditions. Pollution degree 3. Dimensions are 429 mm wide, 306 mm high, and 233 mm deep; net weight 19.154 kg. Standards: IEC 60947-3. Handle and shaft are not included.
- OS630D13FP
ABB OS630D13FP fuse protector, four-pole, front-operated, base mounting. Main circuit rated current 630 A; rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV. Conventional free-air thermal current 630 A at 40 °C; conventional thermal current 570 A fully enclosed. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 18 kA rms for 1 s. Fuse size NH3, DIN fuse system; fourth pole switched-fusible. Lug terminals, 39 mm terminal width, tightening torque 50 to 75 N·m. Pistol handle and shaft included. Pollution degree 3. Dimensions 429 mm wide, 306 mm high, 233 mm deep; net weight 19.654 kg. Standards: IEC 60947-3.