- OS250D04BBN2P
ABB OS250D04BBN2P fuse switch disconnector, 4-pole, front-operated, base mounting. Rated current 250 A at 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV; rated conditional short-circuit current 80 kA at 690 V. Conventional free-air thermal current 250 A at 40 °C; enclosed thermal current 250 A. Rated operational power AC-23A: 75 kW at 220–240 V, 140 kW at 400 V, 145 kW at 415 V, 170 kW at 500 V, 250 kW at 690 V. Short-time withstand current 8 kA rms for 1 s. Power loss 13 W per pole at rated operating conditions. DIN fuse system, NH0/NH1 fuse size. Lug terminals, 25 mm width, tightening torque 30–44 N·m. Pollution degree 3. Fourth pole switched with solid link, right side. Pistol handle and shaft included. Dimensions 262 × 149 × 203 mm; 3.5 kg. Standards: IEC 60947-3.
- OS250D04F
ABB OS250D04F is a four-pole fuse switch disconnector for base mounting, front operated, with a switched fusible fourth pole. It accepts NH0 and NH1 DIN fuse sizes. Rated current is 250 A in the main circuit, with conventional free-air thermal current 250 A at 40 °C and fully enclosed thermal current 250 A. Rated operational voltage is 690 V AC; rated insulation voltage is 1000 V and rated impulse withstand voltage is 12 kV. Rated conditional short-circuit current is 80 kA at 690 V. Power loss is 13 W per pole at rated operating conditions. Terminal type is lug, terminal width 25 mm, tightening torque 30 to 44 N·m. Pollution degree 3. Standards: IEC 60947-3. Handle and shaft are not included. Dimensions: 206 mm width, 199 mm height, 154 mm depth; net weight 4.7 kg.
- OS250D04F-3
The ABB OS250D04F-3 is a four-pole fuse protector for base mounting, front operated, with lug terminals. It accepts NH0 and NH1 DIN fuse sizes. The main circuit is rated 690 V AC, with power loss of 13 W per pole at rated operating conditions. Tightening torque is 30 to 44 N·m. It conforms to IEC 60947-3. Net weight is 4.65 kg. Manufacturer ID: 1SCA022725R1650.
- OS250D04F-60
ABB fuse switch disconnector, model OS250D04F-60, manufacturer ID 1SCA124519R1001. It has four poles, front operation, base mounting, and lug terminals. The main circuit is rated 690 V AC, and the device is built to IEC 60947-3. It accepts DIN fuse systems in NH0 and NH1 sizes. Power loss is 13 W per pole at rated operating conditions. Terminal tightening torque is 30 to 44 N·m. Net weight is 4.65 kg. ETIM classes list it as EC001040 fuse switch disconnector; UNSPSC is 39122233. WEEE category 5 covers small equipment with no external dimension over 50 cm.
- OS250D04FK
The ABB OS250D04FK is a four-pole fuse switch disconnector with a switched-fusible fourth pole, a direct mounted handle, and base mounting. It is front operated with a left-side 04 mechanism and accepts NH0 and NH1 DIN fuse sizes. Rated values include 250 A main circuit current, 690 V AC operational voltage, 1000 V insulation voltage, and 12 kV impulse withstand voltage. Rated conditional short-circuit current is 80 kA at 690 V, and short-time withstand current is 8 kA rms for 1 s. Power loss is 13 W per pole at rated operating conditions. Lug terminals are 25 mm wide with 30 to 44 N·m tightening torque. Dimensions are 220 mm wide, 199 mm high, and 154 mm deep; net weight is 4.9 kg. It conforms to IEC 60947-3.
- OS250D04N1
The ABB OS250D04N1 is a four-pole fuse protector with base mounting and front operation. It is rated 250 A in the main circuit and 690 V AC, with a rated insulation voltage of 1000 V and a rated impulse withstand voltage of 12 kV. Conventional free-air thermal current is 250 A at 40 °C; conventional thermal current fully enclosed is 250 A. Rated conditional short-circuit current is 80 kA at 690 V, and rated short-time withstand current is 8 kA rms for 1 s. It accepts NH0 and NH1 DIN fuses, uses lug terminals 25 mm wide with tightening torque 30 to 44 N·m, and conforms to IEC 60947-3. Dimensions are 206 mm wide, 199 mm high, and 154 mm deep; net weight is 4.2 kg. Handle and shaft are not included.
- OS250D04N1K
The ABB OS250D04N1K is a four-pole front-operated fuse protector with a direct-mounted handle and base mounting. It accepts NH0 and NH1 DIN fuse sizes. The fourth pole, on the left side, is switched with a solid link. Rated current is 250 A in the main circuit; conventional free-air thermal current is 250 A at 40 °C, and fully enclosed conventional thermal current is 250 A. Rated operational voltage is 690 V AC, rated insulation voltage 1000 V, and rated impulse withstand voltage 12 kV. Rated conditional short-circuit current is 80 kA at 690 V. Power loss is 13 W per pole at rated operating conditions. Dimensions are 220 mm wide, 199 mm high, and 154 mm deep; net weight is 4.8 kg. It conforms to IEC 60947-3.
- OS250D04N1P
The ABB OS250D04N1P is a four-pole fuse protector with a front-operated mechanism and base mounting. It accepts NH0 and NH1 DIN fuses and is rated 250 A, with conventional free-air thermal current (Ith) of 250 A at 40 °C and conventional thermal current (Ithe) of 250 A fully enclosed. Rated operational voltage is 690 V AC; rated insulation voltage (Ui) is 1000 V and rated impulse withstand voltage (Uimp) is 12 kV. Rated conditional short-circuit current (Inc) is 80 kA at 690 V, and rated short-time withstand current (Icw) is 8 kA rms for 1 s. Power loss is 13 W per pole at rated operating conditions. It conforms to IEC 60947-3. Dimensions are 262 mm wide, 199 mm high, and 154 mm deep; net weight is 4.8 kg.