The ABB OS250D04FK is a four-pole fuse switch disconnector with a switched-fusible fourth pole, a direct mounted handle, and base mounting. It is front operated with a left-side 04 mechanism and accepts NH0 and NH1 DIN fuse sizes. Rated values include 250 A main circuit current, 690 V AC operational voltage, 1000 V insulation voltage, and 12 kV impulse withstand voltage. Rated conditional short-circuit current is 80 kA at 690 V, and short-time withstand current is 8 kA rms for 1 s. Power loss is 13 W per pole at rated operating conditions. Lug terminals are 25 mm wide with 30 to 44 N·m tightening torque. Dimensions are 220 mm wide, 199 mm high, and 154 mm deep; net weight is 4.9 kg. It conforms to IEC 60947-3.
- OS250D04N1
The ABB OS250D04N1 is a four-pole fuse protector with base mounting and front operation. It is rated 250 A in the main circuit and 690 V AC, with a rated insulation voltage of 1000 V and a rated impulse withstand voltage of 12 kV. Conventional free-air thermal current is 250 A at 40 °C; conventional thermal current fully enclosed is 250 A. Rated conditional short-circuit current is 80 kA at 690 V, and rated short-time withstand current is 8 kA rms for 1 s. It accepts NH0 and NH1 DIN fuses, uses lug terminals 25 mm wide with tightening torque 30 to 44 N·m, and conforms to IEC 60947-3. Dimensions are 206 mm wide, 199 mm high, and 154 mm deep; net weight is 4.2 kg. Handle and shaft are not included.
- OS250D04N1K
The ABB OS250D04N1K is a four-pole front-operated fuse protector with a direct-mounted handle and base mounting. It accepts NH0 and NH1 DIN fuse sizes. The fourth pole, on the left side, is switched with a solid link. Rated current is 250 A in the main circuit; conventional free-air thermal current is 250 A at 40 °C, and fully enclosed conventional thermal current is 250 A. Rated operational voltage is 690 V AC, rated insulation voltage 1000 V, and rated impulse withstand voltage 12 kV. Rated conditional short-circuit current is 80 kA at 690 V. Power loss is 13 W per pole at rated operating conditions. Dimensions are 220 mm wide, 199 mm high, and 154 mm deep; net weight is 4.8 kg. It conforms to IEC 60947-3.
- OS250D04N1P
The ABB OS250D04N1P is a four-pole fuse protector with a front-operated mechanism and base mounting. It accepts NH0 and NH1 DIN fuses and is rated 250 A, with conventional free-air thermal current (Ith) of 250 A at 40 °C and conventional thermal current (Ithe) of 250 A fully enclosed. Rated operational voltage is 690 V AC; rated insulation voltage (Ui) is 1000 V and rated impulse withstand voltage (Uimp) is 12 kV. Rated conditional short-circuit current (Inc) is 80 kA at 690 V, and rated short-time withstand current (Icw) is 8 kA rms for 1 s. Power loss is 13 W per pole at rated operating conditions. It conforms to IEC 60947-3. Dimensions are 262 mm wide, 199 mm high, and 154 mm deep; net weight is 4.8 kg.
- OS250D04N2
The ABB OS250D04N2 is a front-operated, 4-pole DIN fuse switch disconnector with base mounting. It accepts NH0 and NH1 fuse sizes, and the fourth pole is switched with a solid link on the right side. Rated current is 250 A in the main circuit, with a rated operational voltage of 690 V AC and a rated insulation voltage of 1000 V. Conventional free-air thermal current is 250 A at 40 °C. Rated conditional short-circuit current is 80 kA at 690 V, and rated short-time withstand current is 8 kA rms for 1 s. The unit measures 262 mm wide, 199 mm high, and 154 mm deep, weighs 4.2 kg, and conforms to IEC 60947-3. Handle and shaft are not included.
- OS250D04N2-60
ABB fuse protector, model OS250D04N2-60, manufacturer ID 1SCA022845R3570. This four-pole fuse switch disconnector is front operated and base mounted, with lug terminals. It accepts NH0 and NH1 fuses in the DIN fuse system. The main circuit is rated 690 V AC, and power loss is 13 W per pole at rated operating conditions. Terminal tightening torque is 30 to 44 N·m. Dimensions are 310 mm wide, 270 mm high, and 200 mm deep; net weight is 4.3 kg (9.5 lb). It is designed to IEC 60947-3. ETIM 8 and ETIM 9 classify it as EC001040 fuse switch disconnector. WEEE category 5 applies.
- OS250D11
ABB OS250D11 fuse switch disconnector, 2-pole, front-operated, base mounting. Rated current 250 A in the main circuit; conventional free-air thermal current 250 A at 40 °C; fully enclosed thermal current 250 A. Rated operational voltage 690 V AC, rated insulation voltage 1000 V, rated impulse withstand voltage 12 kV. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 8 kA rms for 1 s. Accepts NH0 and NH1 fuses in DIN fuse system. Lug terminals, 25 mm terminal width, tightening torque 30 to 44 N·m. Power loss 13 W per pole at rated operating conditions. Pollution degree 3. Dimensions 152 mm wide, 199 mm high, 154 mm deep; net weight 2.6 kg. Conforms to IEC 60947-3. Handle and shaft not included.
- OS250D12/B60
ABB OS250D12/B60 is a base-mounted fuse switch disconnector with three poles, front operation, and lug terminals. It accepts NH0 and NH1 fuse sizes in the DIN fuse system. The main circuit is rated 690 V AC, with power loss at rated operating conditions of 13 W per pole. Tightening torque for the terminals is 30 to 44 N·m. The device is classified under IEC 60947-3 and carries ETIM 8 and ETIM 9 category EC001040, UNSPSC 39122233, and IGCC 5291. Product net weight is 234 kg. Manufacturer ID 1SCA156571R1001. WEEE category 5 covers small equipment with no external dimension more than 50 cm.