- AF1350-30-11-70 CT19001
The ABB AF1350-30-11-70 CT19001 is a three-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It is rated 1140 V in the main circuit at 50/60 Hz, with a conventional free-air thermal current of 1350 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 1350 A at 1000 V and 40 °C, and AC-3 is 860 A at 220/230/240 V and 55 °C. Rated insulation voltage is 1140 V to IEC 60947-4-1 and VDE 0110 (Gr. C), and 1000 V to UL/CSA. Rated impulse withstand voltage is 8 kV. Dimensions are 438 mm wide, 244 mm deep, and 392 mm high; net weight is 32 kg. Mechanical durability is 0.5 million operations.
- AF1350-30-22 100-250V a.c./d.c
The ABB AF1350-30-22 100-250V a.c./d.c is a 3-pole AC contactor with three normally open main contacts and no normally closed main contacts. It has two normally open and two normally closed auxiliary contacts. The main circuit is rated 1000 V, and the rated operational current AC-1 (Ie) is 1350 A at 1000 V and 40 °C, 1150 A at 55 °C, and 1000 A at 70 °C. Rated operational current AC-3 (Ie) is 860 A at 220/230/240 V and 55 °C. The rated control circuit voltage is 100 to 250 V at 50 Hz. Main circuit terminals are bars. Net dimensions are 438 mm wide, 244 mm deep, and 392 mm high; net weight is 32 kg.
- AF1350-30-22-70
The ABB AF1350-30-22-70 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It operates on a main circuit rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 1350 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 1350 A at 40 °C and 1000 A at 70 °C at both 690 V and 1000 V. Rated operational power AC-3 includes 475 kW at 380/400 V and 800 kW at 690 V. Dimensions are 438 mm wide, 244 mm deep, and 392 mm high, with a net weight of 32 kg.
- AF1350-30-22-70 CT19001
ABB AF1350-30-22-70 CT19001 is a 3-pole AC contactor, manufacturer ID 1SFL657033R7022. It has 3 normally open main contacts, no normally closed main contacts, and 2 NO plus 2 NC auxiliary contacts. The main circuit is rated 1140 V at 50/60 Hz, with conventional free-air thermal current 1350 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 1350 A at 40 °C and 1000 A at 70 °C; AC-3 is 860 A at 220/230/240 V and 55 °C. Rated insulation voltage is 1140 V per IEC 60947-4-1 and VDE 0110 (Gr. C), 1000 V per UL/CSA. Rated impulse withstand voltage is 8 kV. Dimensions are 438 mm wide, 244 mm deep, 392 mm high; weight 32 kg.
- AF1350B-30-22-70
ABB AF1350B-30-22-70 is a 3-pole non-reversing AC contactor, manufacturer ID 1SFL657063R7022. It is rated 1350 A AC1 and 960 A AC3, with 400 HP at 240 V and 800 HP at 480 V. The coil operates over 100-250 V AC/DC. Coil consumption is 48 V·A holding and 2450 V·A pull-in at maximum rated control circuit voltage, 50 Hz. Ambient air temperature limits are -25 to 50 °C with a thermal overload relay fitted and -40 to 70 °C without one, both at 0.85 to 1.1 Uc. Dimensions are 438 mm width, 244 mm depth, and 392 mm height; net weight is 32 kg. Termination is by screw. ETIM class EC000066.
- AF1350T-30-11 230-240V 50/60Hz
The ABB AF1350T-30-11 230-240V 50/60Hz is an AC contactor with three main normally open contacts and no main normally closed contacts, plus two auxiliary normally open and two auxiliary normally closed contacts. The main circuit is rated 1000 V at 50/60 Hz, with conventional free-air thermal current of 1350 A according to IEC 60947-4-1 at 40 °C for open contactors. Rated operational current AC-1 is 1350 A at 1000 V and 40 °C, 1150 A at 55 °C, and 1000 A at 70 °C. AC-3 rated operational power includes 475 kW at 380/400 V and 257 kW at 220/230/240 V. The coil is rated 230 to 240 V at 50 Hz, 60 Hz, and DC operation. Dimensions are 438 mm wide, 244 mm deep, and 392 mm high, with a net weight of 32 kg.
- AF140
ABB AF140 is an industrial catalog item. Key specifications include Number of Batteries: 0, Product Net Width: 86 mm, Product Net Height: 38 mm, and Product Net Depth / Length: 86 mm. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- AF140-30-00-11
The ABB AF140-30-00-11 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main circuit of 690 V at 50/60 Hz. Conventional free-air thermal current is 200 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 140 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, 130 A at 500 V, and 80 A at 690 V, all at 55 °C. Rated operational power AC-3 is 75 kW at 415 V, 90 kW at 440 V and 500 V, 75 kW at 690 V and 380/400 V, and 37 kW at 220/230/240 V. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high; net weight is 1.55 kg.