- OS400D03N3
ABB OS400D03N3 fuse switch disconnector, 3-pole, rated current 400 A, rated operational voltage 690 V AC, rated insulation voltage 1000 V, rated impulse withstand voltage 12 kV. Conventional free-air thermal current 400 A at 40 °C; conventional thermal current 400 A fully enclosed. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 14 kA rms for 1 s. Power loss 30 W per pole at rated operating conditions. Fuse system DIN, fuse sizes NH0, NH1, NH2. Fourth pole: detachable neutral link integrated into the mechanism. Front-operated, base mounting, 03 left-side operating mechanism, lug terminals 25 mm, tightening torque 30 to 44 N·m. Pollution degree 3. Standards: IEC 60947-3. Handle and shaft not included. Dimensions 255 mm wide, 230 mm high, 193 mm deep; net weight 6.78 kg.
- OS400D04BBN2
The ABB OS400D04BBN2 is a 4-pole fuse protector with base mounting and front-operated mechanism. It is rated 400 A in the main circuit, with conventional free-air thermal current 400 A at 40 °C and conventional thermal current 400 A fully enclosed. Rated operational voltage is 690 V AC; rated insulation voltage is 1000 V and rated impulse withstand voltage is 12 kV. It accepts NH0, NH1, and NH2 fuses in the DIN fuse system. The fourth pole is on the right side, switched with a solid link. Terminals are lug type, 25 mm wide, with tightening torque 30 to 44 N·m. Power loss is 30 W per pole at rated operating conditions. Handle and shaft are not included. Standards: IEC 60947-3.
- OS400D04FK
The ABB OS400D04FK is a four-pole fuse switch disconnector with a direct-mounted handle, front-operated, base mounting. It accepts NH0, NH1, and NH2 DIN fuse sizes; the fourth pole is switched-fusible. Rated current is 400 A for the main circuit, with conventional free-air thermal current 400 A at 40 °C and enclosed thermal current 400 A. Rated operational voltage is 690 V AC, rated insulation voltage 1000 V, and rated impulse withstand voltage 12 kV. Rated conditional short-circuit current is 80 kA at 690 V; short-time withstand current is 14 kA rms for 1 s. Power loss is 30 W per pole at rated operating conditions. Lug terminals are 25 mm wide, tightening torque 30 to 44 N·m. Pollution degree 3. Complies with IEC 60947-3. Dimensions: 319 mm wide, 230 mm high, 176 mm deep; 8.42 kg.
- OS400D04N1
The ABB OS400D04N1 is a front-operated, 4-pole fuse protector with a switched fourth pole on the left side using a solid link. It is rated 400 A at 690 V AC, with a rated insulation voltage of 1000 V and a rated impulse withstand voltage of 12 kV. Conventional free-air thermal current is 400 A at 40 °C; fully enclosed conventional thermal current is 400 A. Rated conditional short-circuit current is 80 kA at 690 V, and rated short-time withstand current is 14 kA rms for 1 s. It accepts NH0, NH1, and NH2 fuses in a DIN fuse system and uses lug terminals, 25 mm wide, tightened to 30 to 44 N·m. Mounting is base mounting; handle and shaft are not included. It conforms to IEC 60947-3.
- OS400D04N1P
ABB OS400D04N1P fuse protector, four-pole, front-operated, base mounting, with pistol handle and shaft included. Rated current 400 A; rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV. Conventional free-air thermal current 400 A at 40 °C; conventional thermal current 400 A fully enclosed. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 14 kA rms for 1 s. Fuse system DIN, fuse sizes NH0, NH1, NH2. Fourth pole switched with solid link, left side. Lug terminals, 25 mm wide, tightening torque 30 to 44 N·m. Power loss 30 W per pole at rated operating conditions. Pollution degree 3. Standards: IEC 60947-3. Net dimensions 319 x 230 x 193 mm; net weight 8.41 kg.
- OS400D11
The ABB OS400D11 is a two-pole fuse switch disconnector for base mounting with front operation. It accepts NH0, NH1, and NH2 fuse sizes in the DIN fuse system. The main circuit is rated 400 A at 690 V AC, with a rated insulation voltage of 1000 V and a rated impulse withstand voltage of 12 kV. Conventional free-air thermal current is 400 A at 40 °C; conventional thermal current fully enclosed is 400 A. Rated conditional short-circuit current is 80 kA at 690 V, and rated short-time withstand current is 14 kA rms for 1 s. Power loss is 30 W per pole at rated operating conditions. Cable cross-section is 2.5 to 25 mm², tightening torque 30 to 44 N·m, and terminal width 25 mm. Standards: IEC 60947-3. Handle and shaft are not included.
- OS400D12K
ABB OS400D12K is a 3-pole fuse switch disconnector for DIN fuse systems, accepting NH0, NH1, and NH2 fuse sizes. It is front-operated with a direct mounted handle and base mounting. The main circuit is rated 400 A at 690 V AC, with a rated insulation voltage of 1000 V and rated impulse withstand voltage of 12 kV. Conventional free-air thermal current is 400 A at 40 °C; enclosed thermal current is 400 A. Rated conditional short-circuit current is 80 kA at 690 V. Power loss is 30 W per pole at rated operating conditions. Terminals are lug type, 25 mm wide, tightened to 30 to 44 N·m. Dimensions are 360 mm wide, 365 mm high, and 175 mm deep; net weight 6.61 kg. Standards: IEC 60947-3.
- OS400D12LR
ABB OS400D12LR fuse protector, identified by manufacturer ID 1SCA022853R2010. Three-pole, front-operated, base-mounting fuse switch disconnector for DIN fuse systems in NH0, NH1, and NH2 sizes. Rated current 400 A in the main circuit; conventional free-air thermal current 400 A at 40 °C; conventional thermal current 630 A fully enclosed. Rated operational voltage 690 V AC, rated insulation voltage 1000 V, rated impulse withstand voltage 12 kV, pollution degree 3. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 14 kA rms for 1 s. Power loss 40 W per pole at rated operating conditions. Line terminals left in, right out; lug terminals 25 mm wide; tightening torque 30 to 44 N·m. Dimensions 344 mm wide, 150 mm high, 255 mm deep; net weight 9.6 kg. Conforms to IEC 60947-3. Handle and shaft not included.