- AX50-30-00-86
ABB AX50-30-00-86 AC contactor, manufacturer ID 1SBL351074R8600. Three-pole (3 NO main contacts, 0 NC), block-type, screw terminals. Rated operational voltage 690 V for main and auxiliary circuits at 50/60 Hz. Rated control circuit voltage: 400 to 415 V at 50 Hz, 415 to 440 V at 60 Hz. Conventional free-air thermal current 100 A per IEC 60947-4-1 at 40 °C, open contactors. AC-3 ratings include 50 A at 415 V and 35 A at 690 V, both at 55 °C, with corresponding rated operational power of 25 kW at 415 V and 30 kW at 690 V. Dimensions 70 mm wide, 110 mm deep, 108 mm high; net weight 1.01 kg. Coil terminals IP20, main terminals IP10 per IEC 60529.
- AX50-30-00-88
The ABB AX50-30-00-88 is an AC contactor with three main contacts, normally open, and no auxiliary contacts. It measures 70 mm wide, 110 mm deep, and 108 mm high, and weighs 1.01 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50 or 60 Hz. Rated control circuit voltage is 230 to 240 V at 50 Hz and 240 to 260 V at 60 Hz. Conventional free-air thermal current is 100 A according to IEC 60947-4-1 at 40 degrees C. Rated operational current AC-3 is 50 A at 415 V and 55 degrees C. Screw terminals are used, with main terminals rated IP10 and coil terminals IP20 according to IEC 60529.
- AX50-30-11-26
The ABB AX50-30-11-26 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 82 mm wide, 110 mm deep, and 108 mm high, and weighs 1.05 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Conventional free-air thermal current is 100 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 50 A at 415 V and 55 °C, and rated operational power AC-3 is 25 kW at 415 V. Rated insulation voltage is 690 V according to IEC 60947-4-1 and VDE 0110 (Gr. C). Maximum mechanical switching frequency is 3600 cycles per hour.
- AX50-30-11-36
The ABB AX50-30-11-36 is a block-type AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. Main and auxiliary circuits are rated 690 V at 50/60 Hz. Conventional free-air thermal current is 100 A at 40 °C per IEC 60947-4-1. Rated operational current AC-3 is 50 A at 380/400 V and 415 V, 45 A at 440 V and 500 V, and 35 A at 690 V, all at 55 °C. Rated operational power AC-3 is 22 kW at 380/400 V and 25 kW at 415 V and 440 V. Control circuit voltage is 190 V at 50 Hz and 220 V at 60 Hz. Screw terminals; dimensions 82 x 110 x 108 mm; weight 1.05 kg. Manufacturer ID 1SBL351074R3611.
- AX50-30-11-75
ABB AX50-30-11-75 AC contactor, manufacturer ID 1SBL351074R7511, is a block-type contactor with three main poles (3 NO, 0 NC) and one auxiliary NO plus one auxiliary NC contact. Main and auxiliary circuits are rated 690 V at 50/60 Hz. Conventional free-air thermal current is 100 A at 40 °C per IEC 60947-4-1 for open contactors. AC-3 ratings include 50 A at 380/400 V and 415 V, 45 A at 440 V and 500 V, and 35 A at 690 V, all at 55 °C. Dimensions are 82 mm wide, 110 mm deep, and 108 mm high; net weight 1.05 kg.
- AX50-30-11-80
The ABB AX50-30-11-80 is a block-type AC contactor with three main poles (3 NO, 0 NC) and one auxiliary contact each NO and NC. It is rated 690 V for both main and auxiliary circuits at 50/60 Hz, with a conventional free-air thermal current of 100 A per IEC 60947-4-1 at 40 °C. AC-3 ratings include 50 A at 380/400 V and 415 V (55 °C), 45 A at 440 V and 500 V, 35 A at 690 V, and 53 A at 220/230/240 V, corresponding to 22 kW at 380/400 V and 30 kW at 500 V and 690 V. The coil operates at 220 to 230 V 50 Hz or 230 to 240 V 60 Hz. Dimensions are 82 mm wide, 110 mm deep, and 108 mm high; weight 1.05 kg.
- AX50-30-11-81
ABB AX50-30-11-81 is a 3-pole AC contactor with three normally open main contacts and one NO plus one NC auxiliary contact. Main and auxiliary circuits are rated 690 V at 50/60 Hz. The control circuit is rated 24 V at 50 Hz and 24 V at 60 Hz. Rated operational current AC-3 is 50 A at 415 V and 55 °C, 50 A at 380/400 V and 55 °C, and 35 A at 690 V and 55 °C. Rated operational power AC-3 is 22 kW at 380/400 V and 30 kW at 690 V. Dimensions are 82 mm wide, 110 mm deep, and 108 mm high; net weight is 1.05 kg. Terminals are screw type.
- AX50-30-11-83
The ABB AX50-30-11-83 is an AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. Main and auxiliary circuits are rated 690 V at 50/60 Hz. Conventional free-air thermal current is 100 A according to IEC 60947-4-1 at 40 °C. Rated operational current AC-3 is 50 A at 380/400 V and 415 V, 45 A at 440 V and 500 V, 35 A at 690 V, and 53 A at 220/230/240 V, all at 55 °C. Rated operational power AC-3 is 22 kW at 380/400 V, 25 kW at 415 V and 440 V, and 30 kW at 500 V and 690 V. Coil voltage is 48 V at 50 Hz and 60 Hz. Dimensions are 82 mm width, 110 mm depth, and 108 mm height, with 1.05 kg net weight. Screw terminals are used.