- AX50-30-11-75
ABB AX50-30-11-75 AC contactor, manufacturer ID 1SBL351074R7511, is a block-type contactor with three main poles (3 NO, 0 NC) and one auxiliary NO plus one auxiliary NC contact. Main and auxiliary circuits are rated 690 V at 50/60 Hz. Conventional free-air thermal current is 100 A at 40 °C per IEC 60947-4-1 for open contactors. AC-3 ratings include 50 A at 380/400 V and 415 V, 45 A at 440 V and 500 V, and 35 A at 690 V, all at 55 °C. Dimensions are 82 mm wide, 110 mm deep, and 108 mm high; net weight 1.05 kg.
- AX50-30-11-80
The ABB AX50-30-11-80 is a block-type AC contactor with three main poles (3 NO, 0 NC) and one auxiliary contact each NO and NC. It is rated 690 V for both main and auxiliary circuits at 50/60 Hz, with a conventional free-air thermal current of 100 A per IEC 60947-4-1 at 40 °C. AC-3 ratings include 50 A at 380/400 V and 415 V (55 °C), 45 A at 440 V and 500 V, 35 A at 690 V, and 53 A at 220/230/240 V, corresponding to 22 kW at 380/400 V and 30 kW at 500 V and 690 V. The coil operates at 220 to 230 V 50 Hz or 230 to 240 V 60 Hz. Dimensions are 82 mm wide, 110 mm deep, and 108 mm high; weight 1.05 kg.
- AX50-30-11-81
ABB AX50-30-11-81 is a 3-pole AC contactor with three normally open main contacts and one NO plus one NC auxiliary contact. Main and auxiliary circuits are rated 690 V at 50/60 Hz. The control circuit is rated 24 V at 50 Hz and 24 V at 60 Hz. Rated operational current AC-3 is 50 A at 415 V and 55 °C, 50 A at 380/400 V and 55 °C, and 35 A at 690 V and 55 °C. Rated operational power AC-3 is 22 kW at 380/400 V and 30 kW at 690 V. Dimensions are 82 mm wide, 110 mm deep, and 108 mm high; net weight is 1.05 kg. Terminals are screw type.
- AX50-30-11-83
The ABB AX50-30-11-83 is an AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. Main and auxiliary circuits are rated 690 V at 50/60 Hz. Conventional free-air thermal current is 100 A according to IEC 60947-4-1 at 40 °C. Rated operational current AC-3 is 50 A at 380/400 V and 415 V, 45 A at 440 V and 500 V, 35 A at 690 V, and 53 A at 220/230/240 V, all at 55 °C. Rated operational power AC-3 is 22 kW at 380/400 V, 25 kW at 415 V and 440 V, and 30 kW at 500 V and 690 V. Coil voltage is 48 V at 50 Hz and 60 Hz. Dimensions are 82 mm width, 110 mm depth, and 108 mm height, with 1.05 kg net weight. Screw terminals are used.
- AX50-30-11-84
The ABB AX50-30-11-84 is a block-type AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It is rated 690 V for both main and auxiliary circuits at 50/60 Hz, with a rated insulation voltage of 690 V according to IEC 60947-4-1 and VDE 0110 (Gr. C). The control circuit is rated 110 V at 50 Hz and 110 to 120 V at 60 Hz. AC-3 ratings include 50 A at 415 V and 22 kW at 380/400 V, both at 55 °C. Maximum mechanical switching frequency is 3600 cycles per hour; maximum electrical switching frequency is 600 cycles per hour for AC-1 and AC-3. Dimensions are 82 mm wide, 110 mm deep, and 108 mm high, weighing 1.05 kg.
- AX50-30-11-85
The ABB AX50-30-11-85 is a block-type AC contactor with three main poles (3 NO, 0 NC) and one auxiliary NO plus one auxiliary NC contact. Main and auxiliary circuits are rated 690 V at 50/60 Hz. Conventional free-air thermal current is 100 A at 40 °C per IEC 60947-4-1. Rated operational current AC-3 is 50 A at 415 V and 55 °C, 45 A at 440 V and 55 °C, and 35 A at 690 V and 55 °C; corresponding AC-3 power ratings are 25 kW at 415 V, 30 kW at 690 V, and 22 kW at 380/400 V. The coil operates at 380 to 400 V, 50 Hz, or 400 to 415 V, 60 Hz. Dimensions are 82 mm wide, 110 mm deep, and 108 mm high; weight is 1.05 kg.
- AX50-30-11-86
The ABB AX50-30-11-86 is a 3-pole AC contactor with three normally open main contacts and one NO plus one NC auxiliary contact. Main and auxiliary circuits are rated 690 V at 50/60 Hz. Conventional free-air thermal current is 100 A per IEC 60947-4-1 at 40 °C. Rated operational current AC-3 is 50 A at 415 V and 55 °C, and 35 A at 690 V and 55 °C. Rated operational power AC-3 is 22 kW at 380/400 V and 30 kW at 690 V. The control circuit is rated 400 to 415 V at 50 Hz and 415 to 440 V at 60 Hz. Dimensions are 82 mm wide, 110 mm deep, and 108 mm high, with a net weight of 1.05 kg. Terminals are screw type.
- AX50-30-11-88
ABB AX50-30-11-88 AC contactor, manufacturer ID 1SBL351074R8811. It has 3 main contacts NO and 0 main contacts NC, plus 1 auxiliary contact NO and 1 auxiliary contact NC. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 50 A at 380/400 V and 415 V, 45 A at 440 V and 500 V, 35 A at 690 V, and 53 A at 220/230/240 V, all at 55 °C. Rated operational power AC-3 is 22 kW at 380/400 V, 25 kW at 415 V and 440 V, 30 kW at 500 V and 690 V, and 15 kW at 220/230/240 V. Coil voltage is 230 to 240 V at 50 Hz and 240 to 260 V at 60 Hz. Screw terminals. Dimensions are 82 mm width, 110 mm depth, 108 mm height; weight 1.05 kg.