Product Model
AX50-30-11-84
Material Number
1SBL351074R8411
Manufacturer
ABB
Product ID
74282

Get a Free Quote

Request pricing and availability for AX50-30-11-84.

More parts to source? Send your whole list in one enquiry

Key specifications

Product Net Weight
1.05 kg
Rated Operational Voltage
Auxiliary Circuit 690 V Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz Main Circuit 50 / 60 Hz
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 55 °C 85 A (690 V) 40 °C 100 A (690 V) 70 °C 70 A
Rated Operational Power AC-3 (Pe)
(415 V) 25 kW (440 V) 25 kW (500 V) 30 kW (690 V) 30 kW (380 / 400 V) 22 kW (220 / 230 / 240 V) 15 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 650 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 370 A
See all specifications

Product Highlights

  1. Contact Configuration: 3 normally open main contacts, plus 1 normally open and 1 normally closed auxiliary contact
  2. Coil and Switching: AC-operated control circuit with 110 V at 50 Hz or 110 to 120 V at 60 Hz, maximum mechanical switching frequency 3600 cycles per hour and maximum electrical switching frequency 600 cycles per hour for AC-1 and AC-3
  3. Power and Current Ratings: Rated operational voltage 690 V AC for main and auxiliary circuits, AC-3 rated operational power from 15 kW at 220 to 240 V up to 30 kW at 500 to 690 V, and UL/CSA horsepower ratings from 3 hp single-phase at 120 V to 50 hp three-phase at 550 to 600 V
  4. Short-Time Withstand and Insulation: Rated short-time withstand current 650 A for 10 s and 1000 A for 1 s at 40 °C in free air, rated insulation voltage 690 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), rated impulse withstand voltage 6 kV for the auxiliary circuit
  5. Terminations and Ambient Range: Screw terminals with tightening torque 35 in·lb for the main circuit and 9 in·lb for auxiliary and control circuits, operating ambient air temperature -40 to 70 °C without a thermal overload relay and -25 to 55 °C with one, maximum operating altitude 3000 m without derating
AX50-30-11-84

Product Information

Technical Specifications

Specifications for AX50-30-11-84

ParameterValue
Product Net Width82 mm
Product Net Depth / Length110 mm
Product Net Height108 mm
Product Net Weight1.05 kg
Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO1
Number of Auxiliary Contacts NC1
Rated Operational VoltageAuxiliary Circuit 690 V Main Circuit 690 V
Rated Frequency (f)Auxiliary Circuit 5060 Hz Main Circuit 5060 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 100 A
Rated Operational Current AC-1 (Ie)(220 / 240 V) 55 °C 85 A (690 V) 40 °C 100 A (690 V) 70 °C 70 A
Rated Operational Current AC-3 (Ie)(415 V) 55 °C 50 A (440 V) 55 °C 45 A (500 V) 55 °C 45 A (690 V) 55 °C 35 A (380400 V) 55 °C 50 A (220230240 V) 55 °C 53 A
Rated Operational Power AC-3 (Pe)(415 V) 25 kW (440 V) 25 kW (500 V) 30 kW (690 V) 30 kW (380400 V) 22 kW (220230240 V) 15 kW
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 650 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 370 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 630 A
Maximum Electrical Switching Frequency(AC-1) 600 cycles per hour (AC-3) 600 cycles per hour
ParameterValue
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)Auxiliary Circuit 6 kV
Maximum Mechanical Switching Frequency3600 cycles per hour
Rated Control Circuit Voltage (Uc)50 Hz 110 V 60 Hz 110 ... 120 V
Operate TimeBetween Coil De-energization and NC Contact Closing 7 ... 14 ms Between Coil De-energization and NO Contact Opening 4 ... 11 ms Between Coil Energization and NC Contact Opening 7 ... 22 ms Between Coil Energization and NO Contact Closing 8 ... 27 ms
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Terminal TypeScrew Terminals
General Use Rating UL/CSA(600 V AC) 80 A
Horsepower Rating UL/CSA(120 V AC) Single Phase 3 hp (200 ... 208 V AC) Three Phase 15 hp (220 ... 240 V AC) Three Phase 20 hp (240 V AC) Single Phase 10 hp (440 ... 480 V AC) Three Phase 40 hp (550 ... 600 V AC) Three Phase 50 hp
Tightening Torque UL/CSAAuxiliary Circuit 9 in·lb Control Circuit 9 in·lb Main Circuit 35 in·lb
Ambient Air TemperatureClose to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C Close to Contactor without Thermal O/L Relay -40 ... 70 °C Close to Contactor for Storage -60 ... +80 °C Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstandacc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Object Classification CodeQ
ETIM 7EC000066 - Power contactor, AC switching
ETIM 8EC000066 - Power contactor, AC switching
ETIM 9EC000066 - Power contactor, AC switching
eClassV11.0 : 27371003
UNSPSC39121529
IDEA Granular Category Code (IGCC)4755 >> Contactors
Manufacturer ID1SBL351074R8411

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?