- OS63GD02K
ABB OS63GD02K fuse protector, identified by manufacturer ID 1SCA122906R1001. It is a two-pole, front-operated fuse switch disconnector for base mounting, using NH000 fuses in the DIN fuse system. The main circuit is rated 690 V AC, with a power loss of 4 W per pole at rated operating conditions. Connections are made via screw terminals accepting stranded or flexible conductors from 2.5 to 25 mm², with a tightening torque of 3 N·m to 4 N·m and a main-circuit wire stripping length of 12 mm (0.47 in). Dimensions are 190 mm wide, 170 mm high, and 210 mm deep; net weight is 0.88 kg. It is designed to IEC 60947-3.
- OS63GD03
ABB OS63GD03 is a front-operated, 3-pole fuse protector for base mounting, identified by manufacturer ID 1SCA115206R1001. It accepts NH000 DIN fuse links. Rated current (In) is 63 A in the main circuit; conventional free-air thermal current (Ith) is 63 A at 40 °C, and conventional thermal current (Ithe) is 63 A fully enclosed. Rated conditional short-circuit current (Inc) is 80 kA at 690 V. Power loss is 4 W per pole at rated operating conditions. Cable cross-section and connecting capacity are 2.5 to 25 mm² for stranded and flexible conductors. Line terminals may be top in, bottom out, or bottom in, top out. Pollution degree is 3. Dimensions are 112 mm wide, 112 mm high, and 121 mm deep; net weight is 0.99 kg. Handle and shaft are not included.
- OS63GD04FK
ABB fuse switch disconnector, model OS63GD04FK. Four-pole, front-operated unit with a direct-mounted handle included and base mounting. It accepts NH000 DIN fuse links; the fourth pole is switched-fusible. Rated current is 63 A in the main circuit, with conventional free-air thermal current 63 A at 40 °C and fully enclosed thermal current 63 A. Rated operational voltage is 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV. Rated conditional short-circuit current is 80 kA at 690 V. Power loss is 4 W per pole at rated operating conditions. Screw terminals accept 2.5 to 25 mm² cable, tightening torque 3 to 4 N·m, stripping length 12 mm. Dimensions: 136 mm width, 112 mm height, 165 mm depth; net weight 1.38 kg. Standards: IEC 60947-3.
- OS63GD04N1
The ABB OS63GD04N1 is a four-pole fuse protector for base mounting with front operation. It accepts NH000 DIN fuses and has a rated current of 63 A in the main circuit, a rated operational voltage of 690 V AC, and a rated insulation voltage of 1000 V. Conventional free-air thermal current is 63 A at 40 °C; enclosed thermal current is 63 A. Rated conditional short-circuit current is 80 kA at 690 V, and rated impulse withstand voltage is 12 kV. The fourth pole is on the left side, switched with a solid link. Screw terminals accept 2.5 to 25 mm² cable, with 12 mm stripping length and 3 to 4 N·m tightening torque. It conforms to IEC 60947-3. Handle and shaft are not included.
- OS63GD04N1P
The ABB OS63GD04N1P is a four-pole front-operated fuse switch disconnector for base mounting. It uses NH000 fuses in the DIN system and includes a pistol handle and shaft. The fourth pole is on the left side and is switched with a solid link. Rated current is 63 A in the main circuit, with conventional free-air thermal current 63 A at 40 °C and fully enclosed thermal current 63 A. Rated operational voltage is 690 V AC; rated insulation voltage is 1000 V and rated impulse withstand voltage is 12 kV. Rated conditional short-circuit current is 80 kA at 690 V, and rated short-time withstand current is 2.5 kA rms for 1 s. It conforms to IEC 60947-3. Dimensions are 136 mm wide, 125 mm high, and 121 mm deep; net weight is 1.4 kg.
- OS63GD04N2
The ABB OS63GD04N2 is a 4-pole, front-operated fuse switch disconnector for DIN fuse systems, using NH000 fuse size and base mounting. It is rated 63 A and 690 V AC, with rated insulation voltage 1000 V and rated impulse withstand voltage 12 kV. The fourth pole is switched with a solid link, positioned on the right side. Terminals are screw type, accepting stranded or flexible cable of 2.5 to 25 mm², with 12 mm stripping length and tightening torque of 3 N·m or 4 N·m. Power loss is 4 W per pole at rated operating conditions. Rated conditional short-circuit current is 80 kA at 690 V. It conforms to IEC 60947-3. Handle and shaft are not included.
- OS63GD10
The ABB OS63GD10 is a single-pole fuse protector for DIN NH000 fuse systems, rated 63 A in the main circuit and 690 V AC. It is front operated with base mounting and screw terminals. Conventional free-air thermal current is 63 A at 40 °C; conventional thermal current fully enclosed is 63 A. Rated insulation voltage is 1000 V and rated impulse withstand voltage is 12 kV. Rated conditional short-circuit current is 80 kA at 690 V, and rated short-time withstand current is 2.5 kA rms for 1 s. Cable cross-section is 2.5 to 25 mm² for stranded and flexible conductors. Dimensions are 121 mm wide, 66 mm high and 112 mm deep; net weight 0.5 kg. Pollution degree 3. Standards: IEC 60947-3. Handle and shaft not included.
- OS63GD11K
The ABB OS63GD11K is a two-pole fuse protector for DIN NH000 fuses, front operated and base mounted. It measures 165 mm wide, 91 mm high, and 112 mm deep, and weighs 0.88 kg. Connecting capacity is 2.5 to 25 mm² for stranded and flexible conductors. Power loss is 4 W per pole at rated operating conditions. The main circuit rated operational voltage is 690 V AC.