- OS63GB11
ABB OS63GB11 fuse protector, 2-pole, base mounting, front operated with the operating mechanism located between the poles. Rated current 63 A; rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV. Conventional free-air thermal current 63 A at 40 °C; conventional thermal current 63 A fully enclosed. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 2.5 kA rms for 1 s. Power loss 4 W per pole at rated operating conditions. Accepts British Standard A2-A3 fuses. Cable cross-section 2.5 to 25 mm², screw terminals, tightening torque 3 N·m to 4 N·m, wire stripping length 12 mm. Dimensions 91 mm wide, 112 mm high, 109 mm deep; net weight 0.74 kg. Pollution degree 3. Standards: IEC 60947-3. Handle and shaft not included.
- OS63GB11P
ABB OS63GB11P fuse switch disconnector, 2-pole, rated current 63 A in the main circuit. Rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV. Conventional free-air thermal current Ith 63 A at 40 °C; conventional thermal current Ithe 63 A fully enclosed. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 2.5 kA rms for 1 s. Rated operational power AC-23A: 18.5 kW at 220–240 V, 30 kW at 400 V and 415 V, 37 kW at 500 V, 55 kW at 690 V. Fuse system British Standard, fuse size A2-A3. Front-operated pistol handle and shaft included; base mounting. Screw terminals accept 2.5–25 mm² stranded or flexible cable; tightening torque 3 N·m or 4 N·m; stripping length 12 mm. Pollution degree 3. Standards: IEC 60947-3. Dimensions 91 mm × 112 mm × 109 mm; net weight 0.93 kg.
- OS63GB12
The ABB OS63GB12 is a three-pole fuse switch disconnector for base mounting with front operation. It is rated 63 A in the main circuit and 690 V AC, with a rated insulation voltage of 1000 V and a rated impulse withstand voltage of 12 kV. Conventional free-air thermal current is 63 A at 40 °C, and conventional thermal current fully enclosed is 63 A. Rated conditional short-circuit current is 80 kA at 690 V. It accepts A2-A3 British Standard fuses and cable cross-sections of 2.5 to 25 mm². Power loss is 4 W per pole at rated operating conditions. Dimensions are 112 mm wide, 112 mm high, and 109 mm deep; net weight is 0.99 kg. It conforms to IEC 60947-3. Handle and shaft are not included.
- OS63GB12P
ABB OS63GB12P is a 3-pole fuse switch disconnector for base mounting, front operated, with pistol handle and shaft included. It is rated 63 A at 690 V AC main circuit, with conventional free-air thermal current Ith 63 A at 40 °C and enclosed thermal current Ithe 63 A. Rated insulation voltage is 1000 V and rated impulse withstand voltage is 12 kV. It accepts British Standard fuse sizes A2-A3. Rated conditional short-circuit current is 80 kA at 690 V; rated short-time withstand current is 2.5 kA rms for 1 s. AC-23A rating is 63 A at 500 V and 690 V, with rated operational power 30 kW at 400 V and 55 kW at 690 V. Screw terminals accept 2.5 to 25 mm²; tightening torque 3 to 4 N·m. Standards: IEC 60947-3. Pollution degree 3. Dimensions: 112 mm width, 125 mm height, 109 mm depth; net weight 1.18 kg.
- OS63GB20P
The ABB OS63GB20P is a 2-pole front-operated fuse switch disconnector for British Standard fuse systems, size A2-A3. It is rated 63 A at 690 V AC, with a rated insulation voltage of 1000 V, rated impulse withstand voltage of 12 kV, and rated conditional short-circuit current of 80 kA at 690 V. Conventional free-air thermal current is 63 A at 40 °C; enclosed thermal current is 63 A. It accepts stranded or flexible cable of 2.5 to 25 mm² via screw terminals, with 12 mm stripping length and 3 to 4 N·m tightening torque. Power loss is 4 W per pole at rated operating conditions. It complies with IEC 60947-3, has pollution degree 3, and measures 190 mm wide, 170 mm high, and 145 mm deep, weighing 0.9 kg. A handle and shaft are included.
- OS63GB22N1
ABB OS63GB22N1 is a four-pole fuse switch disconnector for British Standard fuse systems, fuse size A2-A3. It is front-operated with base mounting and screw terminals. The fourth pole is on the left side, switched with a solid link. Rated current is 63 A in the main circuit; conventional free-air thermal current Ith is 63 A at 40 °C, and conventional thermal current Ithe is 63 A fully enclosed. Rated operational voltage is 690 V AC, rated insulation voltage 1000 V, rated impulse withstand voltage 12 kV, and rated conditional short-circuit current 80 kA at 690 V. It conforms to IEC 60947-3. Cable cross-section is 2.5 to 25 mm². Dimensions are 136 mm wide, 112 mm high, and 109 mm deep; net weight is 1.18 kg. Handle and shaft are not included.
- OS63GB22N1P
The ABB OS63GB22N1P is a four-pole fuse switch disconnector for base mounting, front operated, with a pistol handle and shaft included. It uses British Standard A2-A3 fuses and screw terminals. Rated values include 63 A main circuit current, 690 V AC operational voltage, 1000 V insulation voltage, and 12 kV impulse withstand voltage. Conventional free-air thermal current is 63 A at 40 °C; enclosed thermal current is 63 A. Rated conditional short-circuit current is 80 kA at 690 V, and short-time withstand current is 2.5 kA rms for 1 s. Power loss is 4 W per pole at rated operating conditions. Cable cross-section is 2.5 to 25 mm². Dimensions are 136 mm wide, 125 mm high, and 109 mm deep; net weight is 1.37 kg. It conforms to IEC 60947-3.
- OS63GBS30
The ABB OS63GBS30 is a three-pole fuse switch disconnector for base mounting, side operated from the right side. It uses British Standard fuse system A2-A3 fuses. Rated current is 63 A in the main circuit, with conventional free-air thermal current 63 A at 40 °C and fully enclosed thermal current 63 A. Rated operational voltage is 690 V AC; rated insulation voltage is 1000 V and rated impulse withstand voltage is 12 kV. Rated conditional short-circuit current is 80 kA at 690 V, and rated short-time withstand current is 2.5 kA rms for 1 s. Screw terminals accept stranded and flexible cable 2.5 to 25 mm², tightening torque 3 N·m or 4 N·m, stripping length 12 mm. Dimensions are 147 mm wide, 125 mm high, 109 mm deep; net weight 1.2 kg. Standards: IEC 60947-3. Handle and shaft are not included.