- OS63GB20P
The ABB OS63GB20P is a 2-pole front-operated fuse switch disconnector for British Standard fuse systems, size A2-A3. It is rated 63 A at 690 V AC, with a rated insulation voltage of 1000 V, rated impulse withstand voltage of 12 kV, and rated conditional short-circuit current of 80 kA at 690 V. Conventional free-air thermal current is 63 A at 40 °C; enclosed thermal current is 63 A. It accepts stranded or flexible cable of 2.5 to 25 mm² via screw terminals, with 12 mm stripping length and 3 to 4 N·m tightening torque. Power loss is 4 W per pole at rated operating conditions. It complies with IEC 60947-3, has pollution degree 3, and measures 190 mm wide, 170 mm high, and 145 mm deep, weighing 0.9 kg. A handle and shaft are included.
- OS63GB22N1
ABB OS63GB22N1 is a four-pole fuse switch disconnector for British Standard fuse systems, fuse size A2-A3. It is front-operated with base mounting and screw terminals. The fourth pole is on the left side, switched with a solid link. Rated current is 63 A in the main circuit; conventional free-air thermal current Ith is 63 A at 40 °C, and conventional thermal current Ithe is 63 A fully enclosed. Rated operational voltage is 690 V AC, rated insulation voltage 1000 V, rated impulse withstand voltage 12 kV, and rated conditional short-circuit current 80 kA at 690 V. It conforms to IEC 60947-3. Cable cross-section is 2.5 to 25 mm². Dimensions are 136 mm wide, 112 mm high, and 109 mm deep; net weight is 1.18 kg. Handle and shaft are not included.
- OS63GB22N1P
The ABB OS63GB22N1P is a four-pole fuse switch disconnector for base mounting, front operated, with a pistol handle and shaft included. It uses British Standard A2-A3 fuses and screw terminals. Rated values include 63 A main circuit current, 690 V AC operational voltage, 1000 V insulation voltage, and 12 kV impulse withstand voltage. Conventional free-air thermal current is 63 A at 40 °C; enclosed thermal current is 63 A. Rated conditional short-circuit current is 80 kA at 690 V, and short-time withstand current is 2.5 kA rms for 1 s. Power loss is 4 W per pole at rated operating conditions. Cable cross-section is 2.5 to 25 mm². Dimensions are 136 mm wide, 125 mm high, and 109 mm deep; net weight is 1.37 kg. It conforms to IEC 60947-3.
- OS63GBS30
The ABB OS63GBS30 is a three-pole fuse switch disconnector for base mounting, side operated from the right side. It uses British Standard fuse system A2-A3 fuses. Rated current is 63 A in the main circuit, with conventional free-air thermal current 63 A at 40 °C and fully enclosed thermal current 63 A. Rated operational voltage is 690 V AC; rated insulation voltage is 1000 V and rated impulse withstand voltage is 12 kV. Rated conditional short-circuit current is 80 kA at 690 V, and rated short-time withstand current is 2.5 kA rms for 1 s. Screw terminals accept stranded and flexible cable 2.5 to 25 mm², tightening torque 3 N·m or 4 N·m, stripping length 12 mm. Dimensions are 147 mm wide, 125 mm high, 109 mm deep; net weight 1.2 kg. Standards: IEC 60947-3. Handle and shaft are not included.
- OS63GBSL30MNS
ABB OS63GBSL30MNS fuse protector, 3-pole, side-operated, base mounting. Rated operational voltage of the main circuit is 690 V AC. It accepts A2 and A3 fuse sizes in the British Standard fuse system. Connecting capacity is 2.5 to 25 mm² for stranded and flexible conductors, with screw terminals and tightening torque of 3 N·m to 4 N·m. Power loss is 4 W per pole at rated operating conditions. Product net weight is 1.5 kg. The device is classified under IEC 60947-3 and ETIM EC001040 as a fuse switch disconnector. Manufacturer ID 1SCA124587R1001. WEEE category 5: small equipment with no external dimension more than 50 cm.
- OS63GBSL40N1MNS
ABB OS63GBSL40N1MNS fuse switch disconnector, four-pole, side operated, base mounting with screw terminals. Rated operational voltage of the main circuit is 690 V AC. Connecting capacity accepts stranded and flexible conductors from 2.5 to 25 mm². Fuse sizes A2 and A3 are used with the British Standard fuse system. Power loss at rated operating conditions is 4 W per pole. Tightening torque is 3 N·m to 4 N·m. The product net weight is 1.5 kg. It conforms to IEC 60947-3. Manufacturer ID 1SCA124606R1001. ETIM 8 and ETIM 9 classify it as EC001040 fuse switch disconnector.
- OS63GD01
The ABB OS63GD01 is a single-pole fuse protector for NH000 DIN fuse systems, base mounting, front operated, with the switch mechanism on the left side. It is rated 63 A in the main circuit and accepts cable cross-sections of 2.5 to 25 mm², stranded or flexible. Conventional free-air thermal current is 63 A at 40 °C, and conventional thermal current fully enclosed is 63 A. Rated insulation voltage is 1000 V, rated impulse withstand voltage 12 kV, and rated operational voltage 690 V AC. Rated conditional short-circuit current is 80 kA at 690 V. Power loss is 4 W per pole at rated operating conditions. Screw terminals, tightening torque 3 to 4 N·m, wire stripping length 12 mm. Pollution degree 3. Handle and shaft not included. Standards: IEC 60947-3. Dimensions: 65 mm wide, 112 mm high, 121 mm deep; net weight 0.49 kg.
- OS63GD01K
The ABB OS63GD01K is a 1-pole fuse protector with a direct mounted handle, front-operated and base-mounted. It accepts NH000 DIN fuse links and screw terminals for stranded or flexible cable from 2.5 to 25 mm², with a wire stripping length of 12 mm and tightening torque of 3 N·m to 4 N·m. Rated current is 63 A in the main circuit, with conventional free-air thermal current 63 A at 40 °C and fully enclosed thermal current 63 A. Rated operational voltage is 690 V AC, rated insulation voltage 1000 V, and rated impulse withstand voltage 12 kV. Rated conditional short-circuit current is 80 kA at 690 V. Power loss is 4 W per pole at rated operating conditions. Pollution degree 3. Standards: IEC 60947-3.