- OS630B04N2P
The ABB OS630B04N2P is a four-pole fuse switch disconnector with a 630 A main circuit rated current and a 690 V AC main circuit rated operational voltage. It uses British Standard C1-C2 fuse sizes and is base mounted with front operation. The fourth pole is switched with a solid link on the right side. Conventional free-air thermal current is 630 A at 40 °C; fully enclosed conventional thermal current is 570 A. Rated conditional short-circuit current is 80 kA at 690 V, rated short-time withstand current is 18 kA rms for 1 s, and rated impulse withstand voltage is 12 kV. It conforms to IEC 60947-3. Dimensions are 431 mm wide, 306 mm high, and 233 mm deep, weighing 16.4 kg. Lug terminals accept 50 to 75 N·m tightening torque.
- OS630B12
ABB OS630B12 fuse protector, manufacturer ID 1SCA022825R6310. Three-pole, front-operated fuse switch disconnector for base mounting with lug terminals, 39 mm terminal width, and tightening torque 50 to 75 N·m. Rated current 630 A in the main circuit; conventional free-air thermal current 630 A at 40 °C; conventional thermal current 570 A fully enclosed. Rated insulation voltage 1000 V, rated impulse withstand voltage 12 kV, rated operational voltage 690 V AC, and pollution degree 3. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 18 kA rms for 1 s. Power loss 46 W per pole at rated operating conditions. Fuse size C1-C2, British Standard fuse system. Handle and shaft not included. Standards: IEC 60947-3.
- OS630B12P
The ABB OS630B12P is a 3-pole fuse switch disconnector with a pistol handle and shaft, base mounting, and front operation. It is rated 630 A in the main circuit, with conventional free-air thermal current 630 A at 40 °C and fully enclosed thermal current 570 A. Rated operational voltage is 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV. AC-23A rated operational current is 630 A at 380–415 V, 500 V, and 690 V. Rated conditional short-circuit current is 80 kA at 690 V, and short-time withstand current is 18 kA rms for 1 s. It uses British Standard C1–C2 fuses, lug terminals 39 mm wide, tightening torque 50–75 N·m, and complies with IEC 60947-3.
- OS630B21P
ABB OS630B21P fuse switch disconnector, manufacturer ID 1SCA022837R7960. Three-pole, front-operated, base-mounting unit with pistol handle and shaft included. Rated current 630 A; rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV. Conventional free-air thermal current 630 A at 40 °C; fully enclosed thermal current 570 A. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 18 kA rms for 1 s. Power loss 46 W per pole at rated operating conditions. Fuse size C1-C2, British Standard fuse system. Lug terminals, 39 mm terminal width, tightening torque 50 to 75 N·m. Pollution degree 3. Dimensions 341 mm width, 306 mm height, 233 mm depth; net weight 13.6 kg. Standards: IEC 60947-3.
- OS630B22N1
The ABB OS630B22N1 is a four-pole fuse protector with base mounting and front operation. It is rated 630 A in the main circuit, with a conventional free-air thermal current of 630 A at 40 °C and a fully enclosed conventional thermal current of 570 A. Rated operational voltage is 690 V AC, rated insulation voltage 1000 V, and rated impulse withstand voltage 12 kV. Rated conditional short-circuit current is 80 kA at 690 V; rated short-time withstand current is 18 kA rms for 1 s. It uses British Standard C1-C2 fuses, lug terminals 39 mm wide, tightening torque 50 to 75 N·m, and complies with IEC 60947-3. Dimensions are 429 mm wide, 306 mm high, and 233 mm deep; net weight is 18.464 kg. Handle and shaft are not included.
- OS630B22N2
ABB OS630B22N2 fuse protector, manufacturer ID 1SCA022825R6580. Four-pole front-operated switch fuse with solid link in the right-side fourth pole. Rated current 630 A; rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV. Conventional free-air thermal current 630 A at 40 °C; enclosed thermal current 570 A. Rated conditional short-circuit current 80 kA at 690 V; short-time withstand current 18 kA rms for 1 s. Fuse system British Standard, fuse size C1-C2. Lug terminals, 39 mm wide, tightening torque 50 to 75 N·m. Base mounting; pollution degree 3; IEC 60947-3. Dimensions 429 x 306 x 233 mm; net weight 18.464 kg. Handle and shaft not included.
- OS630B30P
ABB fuse protector, model OS630B30P, manufacturer ID 1SCA022837R8340. Three-pole, front-operated fuse switch disconnector for base mounting, with pistol handle and shaft included. Rated current 630 A in the main circuit; conventional free-air thermal current 630 A at 40 °C and 570 A fully enclosed. Rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 18 kA rms for 1 s. Power loss 46 W per pole at rated operating conditions. Fuse size C1-C2, British Standard fuse system. Lug terminals, 39 mm wide, tightening torque 50 to 75 N·m. Pollution degree 3. Standards: IEC 60947-3. Dimensions 343 mm width, 306 mm height, 233 mm depth; net weight 13.6 kg.
- OS630BS03K
ABB OS630BS03K fuse protector, 3-pole, base mounting, side-operated with direct-mounted handle included. Rated current 630 A; rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV. Conventional free-air thermal current 630 A at 40 °C; conventional thermal current 570 A fully enclosed. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 18 kA rms for 1 s. Fuse system British Standard, fuse size C1-C2. Lug terminals, 39 mm terminal width, tightening torque 50 to 75 N·m. Cable cross-section 0.75 to 10 mm². Pollution degree 3. Power loss 46 W per pole at rated operating conditions. Dimensions 414 x 306 x 247 mm; net weight 13.9 kg. Standards: IEC 60947-3.