- OS630BS30
ABB OS630BS30 fuse switch disconnector, 3-pole, side-operated, base mounting. Rated current 630 A; rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV. Conventional free-air thermal current 630 A at 40 °C; conventional thermal current 570 A fully enclosed. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 18 kA rms for 1 s. Fuse system British Standard, fuse size C1-C2. Cable cross-section 0.5 to 10 mm²; lug terminals 39 mm wide; tightening torque 50 to 75 N·m. Power loss 46 W per pole at rated operating conditions. Pollution degree 3. Standards: IEC 60947-3. Net dimensions 414 x 306 x 247 mm; net weight 13 kg. Handle and shaft not included.
- OS630BS30K
The ABB OS630BS30K is a base-mounted fuse protector with a direct-mounted handle. It uses the British Standard fuse system and accepts C1-C2 fuse sizes. Dimensions are 414 mm wide, 306 mm high, and 247 mm deep, with a net weight of 13 kg. Cable cross-section range is 0.5 to 10 mm². Conventional free-air thermal current is 630 A at 40 °C; fully enclosed thermal current is 570 A. Pollution degree 3.
- OS630BS40F
The ABB OS630BS40F is a fuse protector with manufacturer ID 1SCA108149R1001. It measures 247 mm wide, 477 mm high, and 306 mm deep, weighing 15.9 kg. Pollution degree is 3. Conventional free-air thermal current is 630 A at 40 °C; conventional thermal current in fully enclosed conditions is 570 A. Cable cross-section range is 0.5 to 10 mm². Fuse size is C1-C2, British Standard system. The fourth pole is switched-fusible. Handle and shaft are not included.
- OS630BS40FK
The ABB OS630BS40FK is a four-pole fuse switch disconnector with a British Standard fuse system, fuse size C1-C2, and a switched fusible fourth pole. It is rated 630 A in the main circuit and 690 V AC, with a rated insulation voltage of 1000 V and a rated impulse withstand voltage of 12 kV. Conventional free-air thermal current is 630 A at 40 °C; fully enclosed thermal current is 570 A. Rated conditional short-circuit current is 80 kA at 690 V, and rated short-time withstand current is 18 kA rms for 1 s. It uses lug terminals, 39 mm terminal width, 50 to 75 N·m tightening torque, side operation, and base mounting. Dimensions are 247 mm wide, 502 mm high, and 306 mm deep; net weight is 15.9 kg. Standards: IEC 60947-3.
- OS630D01P
ABB OS630D01P is a single-pole fuse protector for DIN NH3 fuses, base mounting and front operated with a pistol handle and shaft included. The main circuit is rated 630 A at 690 V AC, with rated insulation voltage 1000 V and rated impulse withstand voltage 12 kV. Conventional free-air thermal current is 630 A at 40 °C; fully enclosed thermal current is 570 A. Rated conditional short-circuit current is 80 kA at 690 V, and rated short-time withstand current is 18 kA rms for 1 s. It conforms to IEC 60947-3. Dimensions are 167 mm wide, 306 mm high, and 233 mm deep; net weight is 6.524 kg. Lug terminals are 39 mm wide, tightened to 50 to 75 N·m.
- OS630D02
ABB OS630D02 fuse protector, 2-pole, front-operated, base-mounted switch fuse for DIN fuse system, NH3 fuse size. Rated current 630 A; rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV. Conventional free-air thermal current 630 A at 40 °C; conventional thermal current 570 A fully enclosed. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 18 kA rms for 1 s. Power loss 46 W per pole at rated operating conditions. Lug terminals, 39 mm terminal width, tightening torque 50 to 75 N·m. Pollution degree 3. Dimensions 255 mm width, 306 mm height, 233 mm depth; net weight 10.06 kg. Standards: IEC 60947-3. Handle and shaft not included.
- OS630D03-3
The ABB OS630D03-3 is a three-pole fuse switch disconnector for DIN fuse systems, accepting NH2 and NH3 fuse sizes. It is front operated and intended for base mounting, with lug terminals and a tightening torque of 50 to 75 N·m. The main circuit is rated 690 V AC, and power loss is 46 W per pole at rated operating conditions. The product net weight is 13.63 kg. It is classified under ETIM 8 and ETIM 9 as EC001040 fuse switch disconnector. The manufacturer ID is 1SCA114729R1001. The unit is listed under WEEE Category 5, small equipment with no external dimension more than 50 cm.
- OS630D03N3
ABB OS630D03N3 is a 3+N pole fuse switch disconnector for DIN NH3 fuses, front operated and base mounted. Main circuit rated current is 630 A at 690 V AC; rated insulation voltage is 1000 V and rated impulse withstand voltage is 12 kV. Conventional free-air thermal current is 630 A at 40 °C, and fully enclosed conventional thermal current is 570 A. Rated conditional short-circuit current is 80 kA at 690 V, with 1 s short-time withstand current of 18 kA rms. Power loss is 46 W per pole at rated operating conditions. Terminals are lug type, 39 mm wide, tightened to 50 to 75 N·m. Pollution degree 3. Standards: IEC 60947-3. Handle and shaft are not included.