Industrial Automation Parts. Prompt replies from real people.

ABB AF265B-40-22RT-11 4-Pole Contactor

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/25/2026

Q1Can you supply the ABB AF265B-40-22RT-11?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the ABB AF265B-40-22RT-11 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
AF265B-40-22RT-11
Material Number
1SFL547262R1122
Manufacturer
ABB
Product ID
74518

Get a Free Quote

Request pricing and availability for AF265B-40-22RT-11.

More parts to source? Send your whole list in one enquiry

Key specifications

Product Net Weight
5.7 kg
Rated Operational Voltage
Main Circuit 1000 V
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 350 A (1000 V) 60 °C 300 A (1000 V) 70 °C 240 A (690 V) 40 °C 400 A (690 V) 60 °C 350 A (690 V) 70 °C 290 A
Rated Operational Power AC-3 (Pe)
(415 V) 132 kW (380 / 400 V) 132 kW (220 / 230 / 240 V) 75 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2120 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 400 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 865 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 2650 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1224 A
Maximum Mechanical Switching Frequency
300 cycles per hour
See all specifications

Product Highlights

  1. Main and Auxiliary Contacts: 4 NO main contacts, 0 NC main contacts, plus 2 NO and 2 NC auxiliary contacts
  2. Rated Operational Voltage: Main circuit 1000 V
  3. AC-3 Ratings: 265 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, 250 A at 500 V and 690 V, all at 55 °C, rated operational power 132 kW at 415 V and 380/400 V, 75 kW at 220/230/240 V
  4. AC-1 Ratings: 350 A at 1000 V and 40 °C, 300 A at 1000 V and 60 °C, 240 A at 1000 V and 70 °C, 400 A at 690 V and 40 °C, 350 A at 690 V and 60 °C, 290 A at 690 V and 70 °C
  5. Short-time Withstand Current: 2120 A for 10 s, 865 A for 1 min, 400 A for 15 min at 40 °C ambient temperature, in free air, from a cold state
  6. Mechanical Durability: 5 million operating cycles, maximum mechanical switching frequency 300 cycles per hour
  7. Terminal Type: Main circuit bars
  8. Dimensions and Weight: 184 mm net width, 180 mm net depth/length, 225 mm net height, 5.7 kg net weight
AF265B-40-22RT-11

Product Information

Technical Specifications

Specifications for AF265B-40-22RT-11

ParameterValue
Product Net Width184 mm
Product Net Depth / Length180 mm
Product Net Height225 mm
Product Net Weight5.7 kg
Number of Main Contacts NO4
Number of Main Contacts NC0
Number of Auxiliary Contacts NO2
Number of Auxiliary Contacts NC2
Rated Operational VoltageMain Circuit 1000 V
Rated Operational Current AC-1 (Ie)(1000 V) 40 °C 350 A (1000 V) 60 °C 300 A (1000 V) 70 °C 240 A (690 V) 40 °C 400 A (690 V) 60 °C 350 A (690 V) 70 °C 290 A
Rated Operational Current AC-3 (Ie)(415 V) 55 °C 265 A (440 V) 55 °C 265 A (500 V) 55 °C 250 A (690 V) 55 °C 250 A (380400 V) 55 °C 265 A (220230240 V) 55 °C 265 A
Rated Operational Power AC-3 (Pe)(415 V) 132 kW (380400 V) 132 kW (220230240 V) 75 kW
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2120 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 400 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 865 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 2650 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1224 A
Rated Operational Current DC-1 (Ie)(100 V) 1 Pole, 40 °C 400 A (100 V) 1 Pole, 60 °C 350 A (100 V) 1 Pole, 70 °C 290 A (110 V) 1-Pole, 40 °C 400 A (110 V) 1-Pole, 60 °C 350 A (110 V) 1-Pole, 70 °C 290 A (110 V) 2 Poles in Series, 40 °C 400 A (110 V) 2 Poles in Series, 60 °C 350 A (110 V) 2 Poles in Series, 70 °C 290 A (110 V) 3 Poles in Series, 40 °C 400 A (110 V) 3 Poles in Series, 60 °C 350 A (110 V) 3 Poles in Series, 70 °C 290 A (175 V) 2 Poles in Series, 40 °C 400 A (175 V) 2 Poles in Series, 60 °C 350 A (175 V) 2 Poles in Series, 70 °C 290 A (200 V) 2 Poles in Series, 40 °C 400 A (200 V) 2 Poles in Series, 60 °C 350 A (200 V) 2 Poles in Series, 70 °C 290 A (220 V) 2 Poles in Series, 40 °C 400 A (220 V) 2 Poles in Series, 60 °C 350 A (220 V) 2 Poles in Series, 70 °C 290 A (220 V) 3 Poles in Series, 40 °C 400 A (220 V) 3 Poles in Series, 60 °C 350 A (220 V) 3 Poles in Series, 70 °C 290 A (260 V) 3 Poles in Series, 40 °C 400 A (260 V) 3 Poles in Series, 60 °C 350 A (260 V) 3 Poles in Series, 70 °C 290 A (300 V) 3 Poles in Series, 40 °C 400 A (300 V) 3 Poles in Series, 60 °C 350 A (300 V) 3 Poles in Series, 70 °C 290 A (340 V) 3 Poles in Series, 40 °C 400 A (340 V) 3 Poles in Series, 60 °C 350 A (340 V) 3 Poles in Series, 70 °C 290 A (350 V) 4 Poles in Series, 40 °C 400 A (350 V) 4 Poles in Series, 60 °C 350 A (350 V) 4 Poles in Series, 70 °C 290 A (400 V) 4 Poles in Series, 40 °C 400 A (400 V) 4 Poles in Series, 60 °C 350 A (400 V) 4 Poles in Series, 70 °C 290 A (440 V) 4 Poles in Series, 40 °C 400 A (440 V) 4 Poles in Series, 60 °C 350 A (440 V) 4 Poles in Series, 70 °C 290 A (72 V) 1-Pole, 40 °C 400 A (72 V) 1-Pole, 60 °C 350 A (72 V) 1-Pole, 70 °C 290 A (72 V) 2 Poles in Series, 40 °C 400 A (72 V) 2 Poles in Series, 60 °C 350 A (72 V) 2 Poles in Series, 70 °C 290 A (72 V) 3 Poles in Series, 40 °C 400 A (72 V) 3 Poles in Series, 60 °C 350 A (72 V) 3 Poles in Series, 70 °C 290 A (90 V) 1 Pole, 40 °C 400 A (90 V) 1 Pole, 60 °C 350 A (90 V) 1 Pole, 70 °C 290 A
ParameterValue
Rated Operational Current DC-3 (Ie)(110 V) 2 Poles in Series, 40 °C 350 A (110 V) 2 Poles in Series, 60 °C 350 A (110 V) 2 Poles in Series, 70 °C 290 A (110 V) 3 Poles in Series, 40 °C 350 A (110 V) 3 Poles in Series, 60 °C 350 A (110 V) 3 Poles in Series, 70 °C 290 A (220 V) 3 Poles in Series, 40 °C 350 A (220 V) 3 Poles in Series, 60 °C 350 A (220 V) 3 Poles in Series, 70 °C 290 A (72 V) 2 Poles in Series, 40 °C 350 A (72 V) 2 Poles in Series, 60 °C 350 A (72 V) 2 Poles in Series, 70 °C 290 A (72 V) 3 Poles in Series, 40 °C 350 A (72 V) 3 Poles in Series, 60 °C 350 A (72 V) 3 Poles in Series, 70 °C 290 A
Rated Operational Current DC-5 (Ie)(110 V) 2 Poles in Series, 40 °C 350 A (110 V) 2 Poles in Series, 60 °C 350 A (110 V) 2 Poles in Series, 70 °C 290 A (110 V) 3 Poles in Series, 40 °C 350 A (110 V) 3 Poles in Series, 60 °C 350 A (110 V) 3 Poles in Series, 70 °C 290 A (220 V) 3 Poles in Series, 40 °C 350 A (220 V) 3 Poles in Series, 60 °C 350 A (220 V) 3 Poles in Series, 70 °C 290 A (72 V) 2 Poles in Series, 40 °C 350 A (72 V) 2 Poles in Series, 60 °C 350 A (72 V) 2 Poles in Series, 70 °C 290 A (72 V) 3 Poles in Series, 40 °C 350 A (72 V) 3 Poles in Series, 60 °C 350 A (72 V) 3 Poles in Series, 70 °C 290 A
Mechanical Durability5 million
Maximum Mechanical Switching Frequency300 cycles per hour
Rated Control Circuit Voltage (Uc)50 Hz / 60 Hz 24 ... 60 V DC Operation 20 ... 60 V
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 50 Hz 8.5 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 8.5 V·A Pull-in at Max. Rated Control Circuit Voltage 50 Hz 475 V·A Pull-in at Max. Rated Control Circuit Voltage 60 Hz 475 V·A Pull-in at Max. Rated Control Circuit Voltage DC 400 W
Terminal TypeMain Circuit: Bars
Horsepower Rating NEMA(200 V AC) Three Phase 75 Hp (230 V AC) Three Phase 100 Hp (460 V AC) Three Phase 200 Hp (575 V AC) Three Phase 200 Hp
General Use Rating UL/CSA(600 V AC) 300 A
Horsepower Rating UL/CSA(200 ... 208 V AC) Three Phase 40 Hp (200 V AC) Three Phase 75 hp (208 V AC) Three Phase 75 hp (220 ... 240 V AC) Three Phase 40 Hp (220 ... 240 V AC) Three Phase 100 hp (440 ... 480 V AC) Three Phase 100 Hp (440 ... 480 V AC) Three Phase 200 hp (550 ... 600 V AC) Three Phase 125 Hp (550 ... 600 V AC) Three Phase 250 hp
Object Classification CodeQ
ETIM 7EC000066 - Power contactor, AC switching
ETIM 8EC000066 - Power contactor, AC switching
ETIM 9EC000066 - Power contactor, AC switching
eClassV11.0 : 27371003
UNSPSC39121529
IDEA Granular Category Code (IGCC)4755 >> Contactors
Manufacturer ID1SFL547262R1122

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp